Page 11
24EXPLODE VIEW AND PARTS LIST No. PART NAME PART CODE SPECIFICATION QTY REMARK E01 CABINET 3610811100 SGCC, T0.8, PAINTING 1 E02 SPECIAL SCREW 3616029100 M4x12.5, MACHINE 2 E03 FRAME UPPER 3612205800 SGCC T1.2 55X580 1 E04 SCREW TAPPING 3616029950 TTSS HEX F/L 4X8 4 E05 FRAME TOP-L 3612205600 SGCC T1.6 52x500 1 E06 FRAME TOP-R 3612205700 SGCC T1.6 52x500 1 E07 STOPPER SPRING 3615202200 POM 2 E08 COVER BACK AS 3611425510 SGCC 0.35T + EPDM 2T 1 E09 SENSOR PRESSURE 3614825300...
Page 12
25EXPLODE VIEW AND PARTS LIST No. PART NAME PART CODE SPECIFICATION QTY REMARK 3614532900 HIPS, MFC, WH DWD-F1X11(2) 3614532910 ABS+UV SPRAY, MFC, SILVER DWD-F1X13 F01 PLATE T AS3614532920 HIPS, MFC, WH 1DWD-F1X21(2) 3614532930 ABS+UV SPRAY, MFC, SILVER DWD-F1X23 3614533300 HIPS, MFC, WH DWD-F1X31(2) 3614533310 ABS+UV SPRAY, MFC, SILVER DWD-F1X33 F02 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2 F03 PANEL LOWER 3614282801 HIPS 1 F04 COVER PUMP FILTER 3611425801 HIPS 1 PLATE T AS + PANEL...
Page 13
38 MESSAGEERROR CAUSE SOLUTION The water tap is closed. Open the water tap. The filter of the valve inlet is clogged. Clean the filter of the valve inlet. The valve inlet is an inferior product or broke down. Change the valve inlet. The water level sensor (sensor pressure) is an inferior product Change the water level sensor or broke down. (sensor pressure). The drain motor works during water supply. Change the drain motor. The PCB ASS’Y does not check the water level. Change the PCB ASS’Y. The drain...
Page 14
39TROUBLESHOOTING GUIDE MESSAGEERROR CAUSE SOLUTION The water temp. is over 45°C in delicate & wool course. (The thermistor wash is an inferior product or broke down.)Change the thermistor wash. The heater wash dose not work. (The water temp. doesnt rise over 2°C during 15min.)Change the heater wash. The heater worked without the water in the tub. Check the water level and the heater wash. The PCB ASS’Y is an inferior product. Change the PCB ASS’Y. The drain pump filter is clogged. Clean the drain pump...
Page 16
S/M No. : DAEWOO ELECTRONICS CORP. 686, AHYEON-DONG MAPO-GU SEOUL, KOREA C.P.O. BOX 8003 SEOUL, KOREA TELEX: DWELEC K28177-8 CABLE: “DAEWOOELEC” PRINTED DATE: Mar. 2005