Page 1
Owner’s Manual AIR COMPRESSOR 2-gallon 1HP Oil Lubricated Model No. 921.153120 ® CAUTION: Before using this product, read this manual and follow all its Safety Rules and Operating Instructions. • Safety Instructions • Installation & Operation • Maintenance & Storage • Troubleshooting Guide • Parts List • Español, p. 10 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com 08/11/2006 Part No. E102346
Page 2
Table of Contents Page Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Below Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Important Safety Instructions & Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 3
1 Risk of Moving PartsIf the air compressor is in operation, all guards and covers should be attached or installed correctly. If any guard or cover has been damaged, do not operate the equipment until the proper personnel has correctly repaired the equipment. The power cord should be free of any moving parts, twisting and/or crimping while in use and while in storage. Risk of BurnsThere are surfaces on your air compressor that while in operation and thereafter...
Page 4
2 Risk of Explosion or FireNever operate the compressor near combustible materials, gasoline or solvent vapors. If spraying flammable materials, locate the air compressor at least 20 feet away from the spray area. Never operate the air compressor indoors or in a confined area. Risk of BurstingAlways drain the air compressor tank daily or after each use. If the tank develops a leak, then replace the air compressor. Never use the air compressor after a leak has been found or try to...
Page 5
3 Parts & Features See figures below for reference. Pressure Relief Tube Outlet Tube Oil Sight Gauge Oil Fill Cap Pressure Switch This controls the power to the motor and also the cut-in/cut-out pressure settings. This switch serves as the Auto-On/Off positions for the unit. Regulator The air pressure coming from the air tank is controlled by the regulator. To increase the pressure turn the knob clockwise and to decrease the pressure turn the knob...
Page 6
The air compressor should be turned off, unplugged from the power source, the air bled from the tank and the unit allowed time to cool before any maintenance is performed. Personal injuries could occur from moving parts, electrical sources, compressed air or hot surfaces. The quick connect assembly must be attached before use. Failure to assemble correctly could result in leaks and possible injury. If unsure of assembly instructions or you...
Page 7
5 Operating Procedures Daily Shut-Down Procedures 1. Set the Auto-On/Off lever to the Off position. 2. Unplug the power cord from the receptacle. 3. Set the outlet pressure to zero on the regulator. 4. Remove any air tools or accessories. When draining the tank, always use ear and eye protection. Drain the tank in a suitable location; condensation will be present in most cases of draining. 5. Open the drain valve allowing air to bleed from the tank. After all of the air has bled from...
Page 8
NOTE: Any service procedure not covered in the maintenance schedule should be performed by qualified service personnel. The air compressor should be turned off, unplugged from the power source, air bled from the tank and allowed time to cool before any maintenance is performed. To ensure efficient operation and longer life of the air compressor unit, a routine maintenance schedule should be followed. The following schedule is geared toward a consumer whose...
Page 9
77 Troubleshooting Guide PROBLEM POSSIBLE CORRECTION Air leaks at the check valve A defective check valve results in a constant air leak at the pressure relief valve or at the pressure relief valve. when there is pressure in the tank and the compressor is shut off. Drain the tank, then remove and clean or replace the check valve. Air leaks between head and Be sure of proper torque on head bolts. If leak remains, contact a service...