Page 341
19 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 Failed Authentications When ACS evaluates this threshold, it examines the RADIUS or TACACS+ failed authentications that occurred during the time interval that you have specified up to the previous 24 hours. These authentication records are grouped by a common...
Page 342
20 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Note: You can specify one or more filters to limit the failed authentications that are considered for threshold evaluation. Each filter is associated with a particular attribute in the authentication records and only those records whose filter value matches the value that you specify are counted. If you specify multiple filters, only the records that match all the filter conditions are counted. Modify the fields in the Criteria...
Page 343
21 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 Authentication Inactivity When ACS evaluates this threshold, it examines the RADIUS or TACACS+ authentications that occurred during the time interval that you have specified up to the previous 31 days. If no authentications have occurred during the specified...
Page 344
22 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Choose this category to define threshold criteria based on authentications that are inactive. Modify the fields in the Criteria tab as described in Table 123 on page 22. Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 TACACS Command Accounting When ACS evaluates this threshold, it examines the TACACS+...
Page 345
23 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 TACACS Command Authorization When ACS evaluates this threshold, it examines the TACACS+ accounting records that it received during the interval between the previous and current alarm evaluation cycle. If one or more TACACS+ accounting records match, it...
Page 346
24 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 ACS Configuration Changes When ACS evaluates this threshold, it examines the accounting records that it received during the interval between the previous and current alarm evaluation cycle. If one or more accounting records match, it calculates the time that...
Page 347
25 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 ACS System Diagnostics When ACS evaluates this threshold, it examines the accounting records that it received during the interval between the previous and current alarm evaluation cycle. If one or more accounting records match, it calculates the time that...
Page 348
26 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 ACS Process Status When ACS evaluates this threshold, it examines the accounting records that it received during the interval between the previous and current alarm evaluation cycle. If one or more accounting records match, it calculates the time that has...
Page 349
27 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 ACS System Health When ACS evaluates this threshold, it examines whether any system health parameters have exceeded the specified threshold in the specified time interval up to the previous 60 minutes. These health parameters include percentage of CPU...
Page 350
28 Managing Alarms Creating, Editing, and Duplicating Alarm Thresholds Related Topics Creating, Editing, and Duplicating Alarm Thresholds, page 10 Configuring General Threshold Information, page 16 Configuring Threshold Notifications, page 35 ACS AAA Health When ACS evaluates this threshold, it examines whether any ACS health parameters have exceeded the specified threshold in the specified time interval up to the previous 60 minutes. ACS monitors the following parameters: RADIUS Throughput...