Page 61
J Series Serial Commands Technical Reference Information61 of 90020-100796-01 Rev. 1 (10-2011) (NET) Network Setup con’t HOST Set the host name. MAC0 Gets the MAC address of the first ethernet controller. PORT Set the PORT number. SUB0 Set the network subnet mask for the first ethernet controller. EXAMPLES: (NET+ETH0 192.168.1.35) - Set new IP address on the first ethernet controller. (NET+GATE 192.168.0.1) - Set the gateway. (NET+SUB0 255.255.255.0) - Set the subnet mask on the first ethernet...
Page 62
62 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (NRD) General Noise Reduction con’t EXAMPLE: (NRD 32) - Set the noise reduction to mid point for main video. (NTR) NETWORK ROUTING CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set routing for ASCII messages. SUBCODE DESCRIPTION OF USE Used to enable or disable daisy chaining. 0 = RS232, RS422 & Ethernet communications are all separate from one another 1 =...
Page 63
J Series Serial Commands Technical Reference Information63 of 90020-100796-01 Rev. 1 (10-2011) (OST) OSD TRANSPARENCY CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Enable or Disable on screen display transparency. SUBCODE DESCRIPTION OF USE Enable or disable OSD transparency. EXAMPLE: (OST 1) - Enable OSD transparency. (PBC) PIP BORDER COLOR CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control lets...
Page 64
64 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PDT) PEAK DETECTOR CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Enables or disables the peak detector test mode. This is used to aid in setup of input levels. For each color, pixel values very near black will be displayed black, pixel values very near peak level will be displayed full on. All oth- ers will be displayed in mid level grey. Input levels for each...
Page 65
J Series Serial Commands Technical Reference Information65 of 90020-100796-01 Rev. 1 (10-2011) (PIP) PICTURE IN PICTURE CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control enables or disables Picture in Picture (PIP) mode. When this control is enabled for the first time, the first valid video signal starting at slot 1 input 1 is routed to the PIP window. If no signals are present, the first available slot/input combination is selected. PIP and...
Page 66
66 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PLK) PIP User Lockouts con’t EXAMPLES: (PLK L*) - Locks all codes/subcodes in the system (except the PLK and PWR control, which are unlockable) (PLK U*) - Unlocks all codes/subcodes in the system, regardless of which method was used to lock them (PLK LSIN*) - Locks all subcodes within the SIN control (PLK USIN+PIIP) - Following the previous example, this unlocks SIN+PIIP, leaving all other SIN subcodes...
Page 67
J Series Serial Commands Technical Reference Information67 of 90020-100796-01 Rev. 1 (10-2011) (PPA) POSITION PRESET ASPECT CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION When enabled, this control ensures that during auto setup for any source, its aspect ratio is maintained when its default size is calculated. This is similar to cases where a stretch is defined for a source in the lookup table. If dis- abled and no stretch is defined, the source is...
Page 68
68 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PRT) SERIAL PORT CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Status DESCRIPTION Get a list of serial ports available on the device. SUBCODE DESCRIPTION OF USE Read serial ports. EXAMPLE: (PRT?1) - Get list of ports. (PTL) SERIAL PROTOCOL CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Advanced DESCRIPTION Set the protocol for a serial communications...
Page 69
J Series Serial Commands Technical Reference Information69 of 90020-100796-01 Rev. 1 (10-2011) (PWR) POWER CONTROL GROUP: Unsaved SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Change the power state of the projector. Possible values: 0 = Power-Off (to Standby mode) 1 = Power-On (to Lamps On mode) 10 = Cooldown lamp is cooling down. Controlled by lamp (read-only) 11 = Warmup lamp is warming up. Controlled by lamp (read-only) 20 = AutoShutdown mode 1 (read only) 21 =...
Page 70
70 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PXT) PIXEL TRACKING CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Pixel Tracking adjusts the position of the pixel sampling clock to match the input signal. It can only be set on Analog input cards. If adjusted incorrectly, flickering or vertical bars of noise appear across the image. Adjust Pixel Tracking so that the noise either disappears or fills the image. If...