Christie Projector M-Series User Manual
Have a look at the manual Christie Projector M-Series User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 476 Christie manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
M-Series User Manual5-1020-100009-01 Rev.1 (07/08) 5 Troubleshooting If the projector is not operating properly, note the symptoms and use this section as a guide to resolve the problem. If the problem cannot be resolved. contact your dealer for assistance. NOTE: A qualified service technician is required when opening an enclosure to diagnose any “probable cause”. • 5.1 Power • 5.2 Lamp • 5.3 LCD • 5.4 Remote Keypad • 5.5 OSD • 5.6 Ethernet • 5.7 Displays
Section 5: Troubleshooting M-Series User Manual5-2020-100009-01 Rev.1 (07/08) 5.1 POWER 5.1.1 Projector Does Not Power ON 1.Ensure projector is plugged in? Check power switch above power cord is in the ON position. 2.Check that the Status LEDs are ON. While the projector is busy initializing, the LEDs should be cycling. When finished initializing, the Power and Shutter LEDs (the two on the right) should be on. 3.Check the LCD display. While the projector is busy initializing, the display should show “Please wait”. When finished initializing, the display should show “Standby mode”. 4. Check the LCD display for any warnings or errors. 5.2 LAMP 5.2.1 Lamp Does Not Ignite 1.Is there an interlock failure? Check the LCD display for an error. If the other lamp has ignited and an image can be seen, use the remote keypad and check the Sta tus menu for any errors and for the Lamp door interlock status. If not lamp has ignited, use the Virtual OSD on the web interface to check these items. The interlock failure could be an open lamp door or a failed lamp fan. 2. If a DMD temperature is too high, the lamp will not ignite. Cool the projector and try again. Ensure there is proper ventilation. If an optional exhaust is used ensure it has adequate airflow. Using the remote keypad or Virtual OSD as above, check the lamp mode in the Lamp menu. This may be set to a single lamp or dual lamp mode. Check in the Status menu what the reported mode is. 3. For suspected communication failures, power-down the projector and try again. 4. If the lamp does not ignite after the second attempt and after powering down and up again (complete AC power down, then replace the lamp. 5.2.2 Lamp Suddenly Turns OFF 1. Check lamp power through the remote keypad checking the Lamp menu or from the web user interface Advanced: Lamp menu. Try increasing lamp power. 2. The DMDs may be overheated. Check for an alarm condition on the LCD keypad display. 3. Replace the lamp. 5.2.3 Flicker, Shadows Or Dimness 1. Check lamp power through the remote keypad checking the Lamp menu or from the web user interface Advanced: Lamp menu. Try increasing lamp power. 2. Replace the lamp.
Section 5: Troubleshooting M-Series User Manual5-3020-100009-01 Rev.1 (07/08) 5.2.4 LiteLOC™ Does Not Seem to Work 1. Ensure LiteLOC™ is set and enabled in the Advanced: Lamp menu, via the web user interface or using the remote keypad check the Lamp menu. 2. If the lamp power has increased to its maximum in order to maintain a LiteLOC™ setting, LiteLOC™ is automatically terminated. If the values shown in the Lamp menu indicate that the lamp power has reached this “over-drive” state, either reduce your LiteLOC™ setting or install a new lamp. 5.3 LCD 5.3.1 Blank Screen, No Menu Displaying 1. The LCD should never be blank regardless of power state. 2. Press any arrow key on the built-in keypad. The backlight on the LCD and the backlight for the built-in keypad should turn on. If the LCD is still blank, restart the projector. 5.4 REMOTE KEYPAD 5.4.1 Remote Keypad Does Not Seem to Work 1. Replace the batteries. 2. Check if IR signals are received by the projector. Pressing any key on the remote control towards the front or rear sensor, the PWR status LED will blink, regardless if any command is executed. If the LED does not blink, restart the projector. 3. Ensure the remote keypad is enabled. If the projector is powered, using the built-in keypad, open the OSD menu and go to the Main Menu>Configuration>Communication submenu and check the checkboxes for Front IR Enabled and Rear IR Enabled are checked. Enable them if they were disabled and try again. 4. Projector is busy. If the projector is busy in a warm-up mode or in a cool-down mode, the commands from the remote keypad may be ignored. Wait until the projector reaches a stable state (Power ON or Stand By) and try again. 5. Press the PROJ key on the remote keypad. If this brings up a pop-up box on the OSD, ensure that the checkbox is marked to enable the projector. 6. Using the XLR connector, use the remote as a “wired” keypad. If it does work and all the IR sensors have been enabled, then there may be a problem with the IR sensors. 5.5 OSD 5.5.1 The OSD Menu does not display 1. Using the LCD, ensure that OSD Menu is enabled, scroll down until the item OSD is displayed. LCD read “OSD : off” press and hold the OSD soft key on the built-in keypad. The LCD will read “OSD on” and press Menu key OR
5-4M-Series User Manual 020-100009-01 Rev.1 (07/08) Section 5: Troubleshooting 2. Press and hold OSD key on the remote keypad for 2-3 seconds, then press the Menu key on the remote keypad. 5.6 ETHERNET 5.6.1 Trouble Establishing Communication with Projector 1. Ensure any address changes have been saved, and reboot to implement. If you still have trouble establishing communications with a projector added to an existing Ethernet network, the projector’s IP address is likely in conflict with another address already in use. Contact your network administrator. 2. Ensure Ethernet settings are valid for the site. All devices should have the same subnet mask yet unique IP addresses. 5.7 DISPLAYS 5.7.1 The projector is on but there is no display 1. Was a lens cover accidently left on? Remove lens cover. 2. On the LCD display, check that the shutter is open. This will also be indicated by the shutter LED being green. 3. Is the correct input selected. Check cable connections. 4. Check if menus appear on the screen. 5. Can you access test pattern? Ensure a full black test pattern has not been selected for display, press Menu to access test patterns, then cycle patterns with keys. Check your source connections again. 5.7.2 Severe Motion Artifacts 1. Most likely there is a synchronization problem with reversed 3-2 pull-down in 60Hz-to-24Hz film- to-digital conversion in your source. Correct at the source. 2. Set the projector to run in Free fun. Open OSD menu and go to Input Switching & PIP. Ensure that running mode is set to Free run not to Frame Lock. 3. Display a test pattern on the screen, pressing the Test button on the remote keypad. The test pattern should be displayed correctly. If not, contact your dealer for assistance. 5.7.3 Image Appears ‘Squeezed’ or Vertically Stretched into Center of Screen 1. Run auto setup, pressing Auto button on the remote keypad. 2. Check your Resizing selection.
Section 5: Troubleshooting M-Series User Manual5-5020-100009-01 Rev.1 (07/08) 5.7.4 The Display is Jittery or Unstable 1. If the display is jittery or blinking erratically, ensure that the source is properly connected and of adequate quality for detection. With poor quality or improperly connected source, the projector will repeatedly attempt to display an image, however briefly. 2. The horizontal and vertical scan frequency of the input signal may be out of range for the projector. Refer to Section 6 Specifications for scan frequency ranges. 3. The sync signal may be inadequate. Correct the source problem. 5.7.5 The Display is Faint 1. Brightness and/or contrast and/or gamma may be set incorrectly. 2. The source may be double terminated. Ensure the source is terminated only once. 3. The source (if non-video) may need a different sync tip clamp location. 5.7.6 The Upper Portion of the Display is Waving, Tearing or Jittering This can occur with video or VCR sources. Check your source. 5.7.7 Portions of the Display are Cut OFF or Warped to the Opposite edge Resizing may need adjustment. Adjust until entire image is visible and centered. 5.7.8 Display Appears Compressed (Vertically Stretched) 1. The frequency of the pixel sampling clock is incorrect for the current source. 2. Sizing and positioning options may be adjusted poorly for the incoming source signal. 3. Use an anamorphic lens for typical HDTV and anamorphic DVD sources that have been re-sized and vertically stretched, via 3rd-party software. 5.7.9 Data is Cropped from Edges To display the missing material, reduce image size to fill the display area available in the projector, then stretch vertically to fill the screen from top to bottom. Add the anamorphic lens to regain image width. 5.7.10 Display Quality Appears to Drift from Good to Bad, Bad to Good 1. The source input signal may be of low quality. 2. The H or V frequency of the input may have changed at the source end. 5.7.11 Display has Suddenly Frozen If the screen blacks out inexplicably, it is possible that excessive voltage noise on the AC or ground input has interrupted the projector’s ability to lock on to a signal. Power down the projector and disconnect from AC. Then plug in again and power up as usual.
5-6M-Series User Manual 020-100009-01 Rev.1 (07/08) Section 5: Troubleshooting 5.7.12 Colors in the Display are Inaccurate 1. The color, tint, color space and/or color temperature settings may require adjustment at your input source. 2. Try Auto Setup. 3. Ensure signal connections are correct. 4. Ensure the proper channel for this source is being used. 5.7.13 Values in Color Saturation slide bars vary overtime 1. Once defined, Color Saturation slide bar values fluctuate over time and will likely be different upon subsequent visits to this menu. This is normal and should be ignored, as these changes do not redefine the x/y coordinates or color gamut. 5.7.14 Display is Not Rectangular 1. Check leveling of the projector. Ensure the lens surface and screen are parallel to one another. 2. Is the vertical offset correct? Make the necessary adjustments to the vertical offset on the lens mount. 5.7.15 Display is “Noisy” 1. Display adjustment at the input source may be required. Adjust pixel tracking, phase and filter. Noise is particularly common on YPbPr signals from a DVD player. 2. Ensure the video input is terminated (75 S). If it is the last connection in a loop-through chain, the video input should be terminated at the last source input only. 3. The input signal and/or signal cables carrying the input signal may be of poor quality. 4. If the distance between the input source device and the projector is greater than 25 feet, signal amplification/conditioning may be required. 5. If the source is a VCR or off-air broadcast, detail may be set too high.
M-Series User Manual6-1020-100009-01 Rev.1 (07/08) 6 Specifications This section provides detailed M-Series specifications, including: *Due to continuing research, specifications are subject to change without notice. • 6.1 Image Performance • 6.2 Feature Set • 6.3 Image Processor Performance • 6.4 Input (Source Signal) Compatibility • 6.5 Control Signal Compatibility • 6.6 Power Requirements • 6.7 Physical Specifications • 6.8 Reliability and Serviceability • 6.9 Environment • 6.10 Accessories and Service Components • 6.11 Regulatory
Section 6: Specifications M-Series User Manual6-2020-100009-01 Rev.1 (07/08) 6.1IMAGE PERFORMANCE 6.1.1Pixel Format 6.1.2Brightness (ANSI Lumens) 6.1.3Contrast 1080p (H x V square pixels) 1920 x 1080 1080p Imaging Device & Configuration Dark Metal 4 DMD, 3 chip, 0.95” diagonal SXGA+ (H x V square pixels) 1400 x 1050 SXGA+ Imaging Device & Configuration Dark Metal 4 DMD, 3 chip, 0.95” diagonal Projector Base ModelLamp PowerNominal Brightness 350W 1080p370W 9500 350W 9100 300W 7700 350W SXGA+370W 9435 350W 9050 300W 7600 200 W 1080p200W 5100 150W 3800 200W SXGA+200W 5000 150W 3700 Brightness loss 0-24 hours 10% maximum ANSI: 16 pt checker pattern on black screen 450 :1 min 650 :1 nominal Full field: 9 pt average ON/OFF with background light subtraction2000 :1 min (full open aperture) 2500 :1 nominal (full open aperture) 5000 :1 min (with dynamic aperture) 10000 : 1 nominal (with dynamic aperture)
M-Series User Manual6-3020-100009-01 Rev.1 (07/08) 6.1.4Luminance Uniformity 6.1.5Color Uniformity 6.1.6Color Primaries 6.1.7Gamma 6.1.8Grayscale/Color Resolution 6.1.9Color Temperature Dual lamp Full white ANSI 13-pt (w/o electronic corr.) +15%, -23% Single lamp Full white ANSI 13-pt (w/o electronic corr.) +15%, -32% Full white ANSI 13-pt (w/ electronic corr.) +5%. -5% Full black ANSI 13-pt Negative uniformity shall be between -35% and 0% and positive uniformity shall be between 0% and +35%. Full white ANSI 13-pt +-0.005 cluster on u’,v’ chart (CIE 1976) Full black ANSI 13-pt +-0.075 cluster on u’, v’, chart (CIE 1976) ANSI 9 point measurement without YNF x y Red 0.665 ± .025 0.335 ± .025 Green 0.343 ± .040 0.640 ± .040 Blue 0.145 ± .020 0.050 ± .025 White 0.300 ± .050 0.300 ± .050 ANSI 9 point measurement with YNF x y Red 0.670+-0.025 0.330+-0.025 Green 0.300+-0.040 0.673+-0.040 Blue 0.148+-0.020 0.045+-0.025 Default Gamma (all points from 10 to 90 IRE) 2.2 + linear segment Adjustable Gamma range 1.0 to 3.0 Resolution 10 bits (non-linear) min (Gamma encoded) White Default CCT (without YNF) 7500 K ±1000K White YNF CCT (with YNF activation, electronically corrected)6500K ±1000K Range of Adjustment 3200 K – 9300 K Tracking (deviation from normal over full range from 0 – 100 IRE)±500 K max Stability (during rated lamp life) ±500 K max
Section 6: Specifications M-Series User Manual6-4020-100009-01 Rev.1 (07/08) 6.1.10Convergence Convergence zones A, B, C are as defined in Figure 2. Zone A has a diameter of ¼ of the image height. Zone B has a diameter of full image height. All specified convergence errors are between any two colors after a minimum warm-up up of 30 minutes. Convergence is specified with a 1.4-1.8 HD lens ( part number 118-100112-01) in the 1.4:1 position with zero offset. Bore-sight alignment must be adjusted for zero angular error. (Note: convergence error includes the effects of lateral color in the projection lens. Measurements must be done on horizontal and vertical test pattern lines that intersect the center of the image). (Figure applicable to both 1080p and SXGA+) 6.1.11Blemishes Blemishes are to be observed at 1 full screen height distance from the image for a period of 30 seconds. Screen size: 10 foot wide for 350W models, 8 foot wide for 200W models. Blemishes are defined as per TI Specification 2506811. Measurement AreaMaximum Convergence Error (Pixels) Zone A 1/4 Zone B 1/2 Zone C 3/4 Red screen No blemishes Green screen No blemishes Blue screen No blemishes White screen No blemishes Black screen No blemishes