Christie Projector DWU700-GS User Manual
Have a look at the manual Christie Projector DWU700-GS User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 476 Christie manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operation GS Series User Manual41 020-001044-02 Rev. 1 (07-2016) Saturation Note the following about adjusted saturation: • The saturation can be adjusted independently for each color (R,G,B,C,M, and Y). • A saturation level of 0 removes all color from that region. • A saturation level of 254 sets the color region to have maximum color. • A saturation level of 127 does not change the saturation. Gain Note the following about adjusted gain: • The gain can be adjusted independently for each color (R,G,B,C,M,Y, and W). • The range of input is 0 to 254. • The gain changes the intensity level of the respective color. • A gain level of 127 disables the HSG controls for that color. • A gain level less than 127 darkens the respective color. • A gain level of 254 sets the color region to have maximum gain; however, clipping occurs on the signal. • A gain of 127 is the nominal setting. • White provides three gain level controls, one each for the R,G,B component of white.
Operation GS Series User Manual42 020-001044-02 Rev. 1 (07-2016) Light Source menu The Light Source menu sets the light source mode and power preferences. Menu itemDescriptionOptions Light Source Mode Sets the light source mode. • Constant Power • Constant Intensity • ECO 1/ECO 2 • Rental Mode—Adjusts to the lowest fan speeds and switches the laser diode power to the minimum setting. Constant Power Sets the value of the laser diode power. — Constant Intensity Sets the value for the Constant Intensity mode to maintain constant brightness. The light sensor monitors the light level and consumes more power as the laser brightness decays naturally over time. When the laser setting reaches the maximum power, it remains at this setting. Note the following: • Light sensor must be calibrated for Constant Intensity mode to work properly. The calibration must be performed after the laser diode replacement. • Constant Intensity mode is disabled if Light Sensor Calibration is not completed. • Constant Power mode and Constant Intensity mode conflict with each other. When one function is enabled, the other function is automatically disabled. • When Constant Intens ity mode is enabled, the Dymanic Black and RealBlack functions are automatically disabled. — Light Source Info Displays information about the light source in the projector. • Total Projector Hours—Displays the current total number of hours the projector has been used. • LD Hours—Displays the current total number of hours the laser diode has been used. Light Sensor Calibrates the light sensor. — Light Source 1. Light Source Mode 2. Constant Power 4. Light Source Info 5. Light Sensor Constant Power 3. Constant Intensity
Operation GS Series User Manual43 020-001044-02 Rev. 1 (07-2016) Status menu The read-only Status menu lists a variety of details about the standard and optional components currently detected in the projector. For DHD models Status Model Name Sync On Green Main Sync Type Serial Number Native Resolution Firmware Main Input Main Signal Format Main Pixel Clock Main Horz Refresh Main Vert Refresh PIP/PBP Input PIP/PBP Signal Format PIP/PBP Pixel Clock PIP/PBP Sync Type PIP/PBP Horz Refresh PIP/PBP Vert Refresh Light Source Power Total Projector Hours Standby Mode Lens Lock Settings IP Address DHCP System Temperature 0.5W Mode Allow Light Source Hours LC Hours No DHD850-GS
Operation GS Series User Manual44 020-001044-02 Rev. 1 (07-2016) For DW U models Status Model Name Sync On Green Main Sync Type Serial Number Native Resolution Firmware Main Input Main Signal Format Main Pixel Clock Main Horz Refresh Main Vert Refresh PIP/PBP Input PIP/PBP Signal Format PIP/PBP Pixel Clock PIP/PBP Sync Type PIP/PBP Horz Refresh PIP/PBP Vert Refresh Light Source Power Total Projector Hours Standby Mode Lens Lock Settings IP Address DHCP System Temperature 0.5W Mode Allow Light Source Hours LC Hours No DWU850-GS
Operation GS Series User Manual45 020-001044-02 Rev. 1 (07-2016) Input Switching & PIP menu The Input Switching & PIP menu determines ho w the main and PIP/PBP inputs are handled. Menu itemDescriptionOptions Main Input Selects an active input to be used as the main image. — PIP/PBP Input Selects an active input to be used as the PIP/ PBP. — PIP/PBP Enable Toggles between displaying two sources at once (main and PIP/PBP images) or one source only. Refer to Inputs on page 71 and PIP/PBP compatibility on page 75. • Selected checkbox—Turns the PIP/PBP source on . • Cleared checkbox—Turns the PIP/PBP source off. Swap Changes the main image to PIP/PBP, and the PIP/PBP to main image. Swapping is available only when PIP/PBP is enabled. — Size Selects the PIP/PBP size to small, medium, or large. — Main Layout Sets the location of the PIP/PBP image on the screen. — Timing Detection Mode Sets timing detection mode to wide or normal to support additional PC timings. When the projected picture is not completed, this function is used to adjust the picture. For 4:3 input sources not recognized by Wide mode (for example 1400 x 1050), perform Auto Image using Normal mode. • Normal mode—Supports 4:3 input sources. • Wide mode—Supports the 16:9 input source and most 4:3 input sources. Source Info Displays the curre nt source settings. (Read- only) — Input key Lists or changes the sources. — Input Switching & PIP VGA 1. Main Input HDMI1 2. PIP/PBP Input Medium 5. Size Top Right 6. Main Layout Auto Source 7. Timing Detection Mode 3. PIP/PBP Enable 4. Swap 8. Source Info 9. Input Key 10. Blank on Signal Switch
Operation GS Series User Manual46 020-001044-02 Rev. 1 (07-2016) PIP/PBP layout and size A P indicates the primary source region (lighter color) and an asterisk (*) indicates both regions are the same size. Blank on Signal Switch Blanks the screen before timing is stable when changing the source. • On—Blanks the screen before timing is stable when charging source. • Off—Disables blanking the screen. PIP/PBP LayoutPIP/PBP Size SmallMediumLarge PBP, Bigger Left Over-Under, Bigger Upper PBP, Bigger Right Over-Under, Bigger Lower PIP-Bottom Right PIP-Bottom Left PIP-Top Left PIP-Top Right Menu itemDescriptionOptions PPP PPP PPP PPP PPP PPP PPP PPP
Operation GS Series User Manual47 020-001044-02 Rev. 1 (07-2016) Language menu Select an available language for the on-screen display. Test Pattern menu Choose the required internal test pattern to display, or select Off to turn off a test pattern. Web user interface The web user interface provides an alternate way to access the menu functionality on the projector. Language Test Pattern 1. Off 2. Grid 3. White 4. Black 5. Checkerboard 6. Color Bars
Operation GS Series User Manual48 020-001044-02 Rev. 1 (07-2016) Logging on to the web user interface Log onto the web user interface by following the steps below. 1. Open a web browser and type th e IP address (in the address bar) assigned to your projector. 2. From the Access type list, select the log in level. 3. In the Password field, type the password. 4. From the Language list, select the appropriate language. 5. To access the Main window, click Login.
Operation GS Series User Manual49 020-001044-02 Rev. 1 (07-2016) Main tab–General Displays information about the projector, its powe r status, and what is selected for the main and PIP/PBP input sources. Main tab–Status Displays the current status of light source, cooling (fans), version numbers and signal (source) information. Main tab–Lens Controls the focus, lens shift, and zoom adjustments for the lens. PanelDescription ControlSelects main source/PIP source, enables or disables PIP/PBP, changes the layout or PIP size, swap, and change the test pattern. Projector Information Checks the projector information for power status, Pic mute status, on-screen display status, IP address, and MAC address. Switch Switches the on or off status of Power, Pic Mute, and on-screen display.
Operation GS Series User Manual50 020-001044-02 Rev. 1 (07-2016)