Command Control via the Network
Communication Port
The following two ports are assigned for the command control.
TCP #23
TCP #9715
Command Control Settings
Configure the following items form a web browser when command control is used.
When the authentication setting is enabled, the following settings are required.
Command Control via the Network
Port Settings
Network Control 
Port1 (Port: 23)Port openClick the [Enable] check box to open...

Page 12

10LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
Command Control via the Network (continued)
Command Format
[TCP #23]
1. Protocol
Consist of header (7 bytes) + command data (6 bytes)
2. Header
BE + EF + 03 + 06 + 00 + CRC_low + CRC_high
CRC_low: Lower byte of CRC flag for command data
CRC_high: Upper byte of CRC flag for command data
3. Command data
Command data chart
byte_0 byte_1 byte_2 byte_3 byte_4 byte_5
Action Type Setting code
low high low high low high
Action (byte_0 - 1)
Action...

Page 13

11LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
Command Control via the Network (continued)
Decreasing the projector setting value (Decrement command)
(1) The PC sends the following decrement code to the projector.
  Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
(2) The projector decreases the setting value on the above setting code.
(3) The projector returns the response code ‘06H’ to the PC.
When the projector cannot understand the received command
When the...

Page 14

12LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
7. Reply Data
The connection ID (the data is same as the connection ID data on the sending 
data format) is attached to the Network control commands reply data.
ACK reply: ‘06H’ + ‘xxH’
NAK reply: ‘15H’ + ‘xxH’
Error reply: ‘1CH’ + ‘xxxxH’ + ‘xxH’
Data reply: ‘1DH’ + ‘xxxxH’ + ‘xxH’
Projector busy reply: ‘1FH’ + ‘xxxxH’ + ‘xxH’
Authentication error reply: ‘1FH’ + ‘0400H’ + ‘xxH’
(‘xxH’ : connection ID)
Automatic Connection Break
The TCP...

Page 15

13LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
RS-232C Communication / Network command table
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
Power Set TURN OFF BE EF 03 06 00 2A D3 01 00 00 60 00 00
TURN ON BE EF 03 06 00 BA D2 01 00 00 60 01 00
Get BE EF 03 06 00 19 D3 02 00 00 60 00 00
(Example Return)
00 00     01 00 02 00
(Off) (On) (Cool Down)
Input Source Set HDMI BE EF 03 06 00 0E D2 01 00 00 20 03 00
RGB1 BE EF 03 06 00 FE D2 01 00 00 20 00 00
RGB2 BE EF...

Page 16

14LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
RS-232C Communication / Network command table
GAMMA Set #1 DEFAULT BE EF 03 06 00 07 E9 01 00 A1 30 20 00
#2 DEFAULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00
#3 DEFAULT BE EF 03 06 00 67 E8 01 00 A1 30 22 00
#4 DEFAULT BE EF 03 06 00 F7 E9 01 00 A1 30 23 00
#5 DEFAULT BE EF 03 06 00 C7 EB 01 00 A1 30 24 00
#6 DEFAULT BE EF 03 06 00 57 EA 01 00 A1 30 25 00
#1 CUSTOM BE EF...

Page 17

15LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
RS-232C Communication / Network command table
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
COLOR TEMP Set #1 HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00
#2 MID BE EF 03 06 00 9B F4 01 00 B0 30 02 00
#3 LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00
#4 Hi-BRIGHT-1 BE EF 03 06 00 3B F2 01 00 B0 30 08 00
#5 Hi-BRIGHT-2 BE EF 03 06 00 AB F3 01 00 B0 30 09 00
#6 Hi-BRIGHT-3 BE EF 03 06 00 5B F3 01 00 B0 30 0A 00
#1 CUSTOM...

Page 18

16LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
RS-232C Communication / Network command table
MY MEMORY Load Set 1 BE EF 03 06 00 0E D7 01 00 14 20 00 00
2 BE EF 03 06 00 9E D6 01 00 14 20 01 00
3 BE EF 03 06 00 6E D6 01 00 14 20 02 00
4 BE EF 03 06 00 FE D7 01 00 14 20 03 00
MY MEMORY Save Set 1 BE EF 03 06 00 F2 D6 01 00 15 20 00 00
2 BE EF 03 06 00 62 D7 01 00 15 20 01 00
3 BE EF 03 06 00 92 D7 01 00 15 20 02 00
4...

Page 19

17LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
RS-232C Communication / Network command table
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
COLOR SPACE Set AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00
RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00
SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00
REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00
REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00
Get BE EF 03 06 00 3D 72 02 00 04 22 00 00
COMPONENT Set COMPONENT BE EF 03 06 00...

Page 20

18LWU420 User Manual-Technical Guide 020-000320-01 Rev. 1 (06-2010)
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
RS-232C Communication / Network command table
AUTO KEYSTONE V 
EXECUTEExecute BE EF 03 06 00 E5 D1 06 00 0D 20 00 00
AUTO KEYSTONE V Set TURN OFF BE EF 03 06 00 EA D1 01 00 0F 20 00 00
TURN ON BE EF 03 06 00 7A D0 01 00 0F 20 01 00
Get BE EF 03 06 00 D9 D1 02 00 0F 20 00 00
KEYSTONE H Get BE EF 03 06 00 E9 D0 02 00 0B 20 00 00
Increment BE EF 03 06 00 8F D0 04 00 0B 20...