39 ADVANCED PROGRAMMING OPTIONS 5. Press thedonebutton. 6. Close the door.
40 ADVANCED PROGRAMMING OPTIONS Keypad lockout The keypad lockout feature lets you “lock” the thermostat at one of three levels that increasingly limit anyone’s ability to make changes by pressing buttons. The levels are: 1 – You can change the temperature settings, the time of day, and the day of the week only 2 – You can change the temperature settings only 3 – The entire keypad is locked, allowing no changes Here’s how to lock the keypad on each of the three levels. 1. Open the door. 2. Press and hold thebuttons underneath the heat and cool setpointssimultaneously (the two bottom buttons on the right) until the screen displays the reset reminders and01in the lower right corner. 3. Press theuparrow button until01changes to04with the number4(change indication) next to it. 4. Press therightmost lower buttonthen press theup arrow button until the screen displays the level you want –1, 2or3. You will also see apadlock iconon the screen.
41 ADVANCED PROGRAMMING OPTIONS 5. Press thedonebutton. 6. Close the door. Unlocking the Keypad Here’s how to temporarily unlock the keypad after you have locked it. 1. Open the door. 2. Press and hold theupanddownbuttons on the right simultaneously for about five seconds. 3. Thepadlock iconwill disappear. This means the keypad is unlocked and can be used. The keypad will revert back to the locked state after you’ve stopped pushing buttons for two minutes. 4. Close the door.
42 ADVANCED PROGRAMMING OPTIONS Changing from programmable to nonprogrammable It is possible to convert your thermostat’s operation from programmable to nonprogrammable. This eliminates its advanced features. When switching to the nonprogrammable format, you lose the programming, hold, vacation and Smart Recovery features. Switching to nonprogrammable also means you’ll give up some of the thermostat’s energy saving features. The time of day and day of the week will still show on the display and you will be able to increase or decrease the temperature settings manually. Here’s how to switch to nonprogrammable. 1. Open the door. 2. Press and hold thebuttons underneath the heat and cool setpointssimultaneously (the two bottom buttons on the right) until the screen displays the reset reminders and01in the lower right corner. 3. Press theuparrow button until01changes to05withP (programmable) next to it.
43 ADVANCED PROGRAMMING OPTIONS 4. Press therightmost lower buttonthen press theup arrow button until the screen displaysnP (nonprogrammable). 5. Press thedonebutton. 6. Close the door.
44 ADVANCED PROGRAMMING OPTIONS Changing the number of programming periods Your thermostat is preset with four time periods. You can change this to two. Here’s how to change the number of periods in the day. 1. Open the door. 2. Press and hold thebuttons underneath the heat and cool setpointssimultaneously (the two bottom buttons on the right) until the screen displays the reset reminders and01in the lower right corner. 3. Press theuparrow button until01changes to06with4 (time periods) next to it. 4. Press therightmost lower buttonthen press theupar- row button until the screen displays2. 5. Press thedonebutton. 6. Close the door.
45 ADVANCED PROGRAMMING OPTIONS Turning on the programmable fan feature When you turn on the programmable fan feature using these instructions, you can program the fan selection to “auto” or “on” for each of the program schedule periods. (Learn more about this on page 25.) 1. Open the door. 2. Press and hold thebuttons underneath the heat and cool setpointssimultaneously (the two bottom buttons on the right) until the screen displays the reset reminders and01in the lower right corner. 3. Press theuparrow button until01changes to07with OF(fan mode) next to it. 4. To turn the fan on, press therightmost lower button then press theuparrow button until the screen displays ON. To turn the fan off, press therightmost lower but- tonthen press thedownarrow button until the screen displaysOF(off). 5. Press thedonebutton. 6. Close the door.
46 ADVANCED PROGRAMMING OPTIONS Turning off the daylight savings time feature The thermostat will automatically change the clock according to daylight savings time procedures twice a year. Here’s how to turn off the daylight savings time feature so the clock doesn’t automatically change. 1. Open the door. 2. Press and hold thebuttons underneath the heat and cool setpointssimultaneously (the two bottom buttons on the right) until the screen displays the reset reminders and01in the lower right corner. 3. Press theuparrow button until01changes to08with On (DST feature)next to it. 4. Press therightmost lower buttonthen press theupar- row button until the screen displaysOFfor off. 5. Press thedonebutton. 6. Close the door.
47 SPECIAL FEATURES Hybrid Heat (heat pump with a furnace system only) This thermostat works with the Carrier Hybrid Heat systems offering maximum comfort and economy by automatically controlling whetheryour system delivers heating with the heat pump, with the furnace, or with both options working together. Service reminders The thermostat tells you when it’s time to change the UV light in the evaporator coil box connected to the furnace (if equipped), humidifier pad (if equipped), and furnace filter. Each reminder –check UV light, check hum pad, check filter– will be displayed on the upper left of the screen. (For important safety reasons, ask your dealer to replace your UV light.) To remove the reminder after you or your dealer have replaced the indicated product, press and hold thedonebutton for about three seconds. Outdoor temperature display The thermostat automatically displays the outdoor temperature only when the door is closed.
48 SPECIAL FEATURES Auto changeover The thermostat displays one of five modes:heat,cool,Emheat(heat pump version only),heat cool(auto mode) andoff. When the mode selection is for both heating and cooling – auto mode – the thermostat is in auto changeover mode. This allows the system to switch from heating to cooling – or from cooling to heating – to maintain the temperatures you’ve programmed. It does this automatically. Smart Recovery The Smart Recovery feature transitions your home from one temperature period (wake, day, evening, sleep) to the next so that the your home’s temperature matches the temperature setting at the start ofeach time period. This means, for example, that if your sleep period temperature setting is lower than the period that precedes it, the thermostat will start cooling down the home before the beginning of the scheduled sleep period. It does this at an energy --efficient rate. This not only helps make your home as comfortable as possible, it also makes your thermostat more cost effective. Call your dealer to adjust Smart Recovery settings.