    							61 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index4.
    Start ScanGear CS-U as a TWAIN driver.
    The mothods for starting TWAIN drivers vary between application
    programs. For example of PhotoStudio 2000, click the [File] menu and
    select [Acquire]. See the respective manuals for other programs.
    5.The ScanGear CS-U main window opens.
    If the Advanced Mode main window appears, click the Simple Mode
    button.
    Note
    If you see an image in the Preview Area this means one
    of the preview settings has been switched on with the
    Preferences sheet.  Otherwise, the Preview Area is
    empty. 
    						
    							62 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index6.
    Click the down-arrow for Image Type and select a setting from the
    drop-down list. (p.31)
    Note
    Your selection automatically sets the mode for the
    scanning job.
    7.Review the settings you see below the Image Type selection (Color
    Mode, Resolution, Width, Height, Size, Paper Size). (p.32-35)
    If you are satisfied with these settings go on to the next step.
    Note
    •On the Simple Mode sheet you click one of the flat
    buttons (the black inverted triangles) to open a
    pop-up menu and select another setting.
    •You can click the Edit Image Type button and
    define up to 12 custom Image Types in the Image
    Type Settings dialog box. (p.34)
    •Click the Magazine check box (p.36) on when
    scanning magazine pages to enable moiré
    reduction and reduce dot patterns. 
    						
    							63 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index8.
    Click the Preview button to pre-scan the image and display it in the
    Preview Area. 
    						
    							64 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index9.
    Click a button in the Toolbar (p.27) to manipulate the image.
    Note
    You can click the Auto Tone button (p.29) to have
    ScanGear CS-U automatically adjust the color tones of
    the scanned image. This is the only color adjustment
    you can make in the Simple Mode. To perform more
    detailed color adjustments, click the Advanced Mode
    button then click the Tone tab to open the Tone
    Sheet.(p.41)
    10.Specify the scanning area.
    Point to one corner of the area of the image that you want to scan.
    Click the left mouse button and, while holding the mouse button
    down, drag the mouse pointer to the opposite corner of the area
    you want to scan. Release the mouse button.
    The area will be boxed in by a rectangle.
    11.Click the Scan button to scan the image.
    The image is acquired in the software application.
    12.Close the ScanGear CS-U window. You can edit or save the image
    with the application software. 
    						
    							65 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index
    Scanning in the Advanced Mode
    This is a brief overview of the general procedure for previewing and
    scanning an original in the Advanced Mode.
    1.Place the original on the scanner.
    Note
    For details about positioning the original on the
    scanner, see your scanner users manual.
    2.Start the software application you are going to use.
    3.Confirm that your scanner is selected in the Select Source (or its
    equivalent) dialog box. (p.60)
    4.Start ScanGear CS-U as a TWAIN driver.
    The mothods for starting TWAIN drivers vary between application
    programs. See the respective manuals for application programs. 
    						
    							66 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index5.
    The ScanGear CS-U main window opens.
    If the Simple Mode main window appears, click the Advanced Mode
    button.
    Note
    If you see an image in the Preview Area this means one
    of the preview settings has been switched on with the
    Preferences sheet. : Otherwise, the Preview Area is
    empty.
    6.In the Main sheet adjust the settings for the Color Mode, Output
    Resolution, Selection (Scanning area), and Scale. 
    						
    							67 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index7.
    In the Scanner sheet, specify a variety of settings for operation of
    the scanner. (p.53)
    8.Click the Preview button to pre-scan the image and display it in the
    Preview Area.
    9.Click a button in the Toolbar (p.27) to manipulate the image. 
    						
    							68 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index10.
    Adjust the image quality with the tools and options provided on
    the Tone (p.41) or Halftone (p.52) sheet.
    11.Specify the scanning area.
    Point to one corner of the area of the image that you want to scan.
    Click the left mouse button and, while holding the mouse button
    down, drag the mouse pointer to the opposite corner of the area
    you want to scan. Release the mouse button.
    The area will be boxed in by a rectangle.
    12.After performing all the settings, click the Scan button to scan the
    image.
    The image is acquired in the software application.
    13.Close the ScanGear CS-U window. You can edit or save the image
    with the application software. 
    						
    							69 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index
    Scanning Film
    Use the following procedures to scan 35 mm film with the film adapter
    unit built into the scanner.
    Note
    Please see the Getting Started guide supplied with the
    scanner to learn how to set film on it.
    1.Place the film in the film guide, set the loaded film guide on the
    platen and close the document cover.
    2.Select Film Adapter as the Image Source.
    In Advanced mode, click the Scanner tab and select it.
    The Preview area shape will change to a horizontal rectangle and allow
    you to set the film type.
    Simple Mode Advanced Mode 
    						
    							70 chapter 5
    Scanning an
    Original
    Top  Page
    Glossary
    Contents
    Index
    3.Select the film type.
    Select positive or negative, color or monochrome to match your film.
    4.Click the Preview button.
    The image is displayed in the preview area. Specify the scan area of the
    preview image.
    5.Set the color mode, resolution, magnification and color
    adjustments as required.
    6.Click the Scan button.
    The image will be sent to the application started by ScanGear CS-U.
    Simple ModeAdvanced Mode 
    						