Page 11
ENG-10 Slide the tilt-lock button in the direction of arrow A. Loosen the tilt lock knob by turning it in the direction of arrow B. Using Tilt When you tilt the lens, sharp portions of the tilt mechanism are exposed and care should be taken to avoid touching these portions. T urn the tilt lock knob in the direction of the arrow to lock the amount of tilt for the shot. T urn the tilt knob to adjust the amount of tilt. Focus the shot by turning the focusing ring. To keep the tilt scale locked in the “0”...
Page 12
ENG-11 4. Shift Function Shifting moves the optical axis of the lens in parallel off the center of the imaging plane. Shift can be used to good effect in the situations shown below. ●If you photograph a subject such as a building with a normal lens, the top of the building tapers away. But by placing the camera parallel to the building and shifting the lens, you can correct this tapering effect.●When you are shooting a reflective subject, you can move the camera to a position where the camera does not...
Page 13
ENG-12 Using ShiftTurn the shift lock knob in the direction of the arrow to lock the amount of shift for the shot. Loosen the shift lock knob by turning it in the direction of the arrow. T urn the shift knob to adjust the amount of shift. Focus the shot by turning the focusing ring. When you shift the lens, sharp portions of the shift mechanism are expos\ ed and care should be taken to avoid touching these portions. For EOS cameras with built-in flash, ther\ e may be contact with the lens while you...
Page 14
ENG-13 5. Rotation The rotation function enables you to change the direction of tilt or shift by rotating the tilt-shift mechanism. With the lens mounted on the camera, push the rotation lock release button towards the mount and then turn the tilt-shift mechanism. ●The rotation mechanism can be rotated through ±90°. The lens clicks every 30° and locks in place in the 90° position. ●When rotating the lens, set the tilt and shift scales to the “0” p\ osition. ● Note that rotating the tilt-shift mechanism...
Page 15
ENG-14 Changing the Operation Direction of Tilt and Shift (TS rotation Function) When the tilt and shift are used in a parallel direction, vignetting will occur in the areas marked in gray in the following table. In order to prevent shifts in position while shooting, shooting while TS rotation is locked, or shooting per click position is recommended. By using the TS rotation function, the relationship of the tilt and shift’s operation direction can switch from right angle to parallel. Press the TS...
Page 16
ENG-15 The depth of field is the distance in front of and behind the plane of focus on the subject that appears sharp. The depth of field is indicated by the area between the depth-of-field scale lines below the distance scale. The infrared index corrects the focus setting when using monochrome infrared film. Focus on the subject in MF, then adjust the distance setting by moving the focusing ring to the corresponding infrared index mark. 6. Depth-of-Field Scale (TS-E24mm f/3.5L II) 7. Infrared Index...
Page 17
ENG-16 8.TS-E Tripod Adapter (Sold Separately)9. Exposure With some camera models, the tilt, shift and rotation functions cannot be used when the camera is mounted directly on a tripod. When this happens, fit the optional TS-E tripod adapter into the tripod mount socket on the camera before mounting the camera on the tripod.Shots can be taken using AE (automatic exposure) as long as the tilt and shift scales are set to the “0” position. The use of AE is not recommended when the lens is tilted or shifted...
Page 18
ENG-17 10. Hood (TS-E24mm f/3.5L II) The EW-88B lens hood can keep unwanted light out of the lens, and also protect\ s the lens from rain, snow, and dust. To attach the hood, align the hood’s attachment position mark with the red dot on the front of the lens, then turn the hood as shown by the arrow until the lens’ red dot is aligned with the hood’s stop position mark. The hood can be reverse-mounted on the lens for storage. When attaching or detaching the hood, grasp the base of the hood to turn\ it....
Page 19
ENG-18 Y ou can attach filters to the filter mounting thread on the front of the lens. 11. Filters (Sold Separately) (TS-E24mm f/3.5L II) ● Only one filter may be attached. ● Use a polarizing Canon filter (82mm). Afilter cannot be used with TS-E17mm f/4L. 12. Infinity Compensation Mark (TS-E24mm f/3.5L II) To compensate for shifting of the infinity focus point that results from changes in temperature. The infinity position at normal temperature is the point at which the vertical line of the L mark is...
Page 20
ENG-19 13. Extension Tubes (Sold Separately) For TS-E24mm f/3.5L II, you can attach extension tube EF12 II for magnified shots. The shooting distance and magnification are shown below. EF12 II 182 198 0.85 0.51 Focusing Distance Range (mm) Magnification ( ×) Close distance Long distance Close distance Long distance ● The extension tubes EF12 II and EF25 II cannot be used with TS-E17mm f/4L. ● Although extension tube EF25 II can be attached on TS-E24mm f/3.5L II, it is not recommended because the...