Canon large format printer imagePROGRAF iPF6400 User Manual
Here you can view all the pages of manual Canon large format printer imagePROGRAF iPF6400 User Manual. The Canon manuals for Large format printer are available online for free. You can easily download all the documents as PDF.
Page 791
9 The Output Color Measurement Data dialog box is displayed. Select the file to save the color measurement data into and click the OK button. 10 The Acquire Color Measurement Data dialog box is displayed. Click the Execute button. The color chart is printed and color measurement be- gins. Note •You can exit the acquire color measurement data operation in the middle by clicking the Cancel button. However, itmay take some time to end. iPF6400...
Page 792
11 Click the OK button. Once the color measurement has finished, the color measurement data is saved on the computer. Executing Color Check Executing Color Check When a color check is executed, a built-in pattern is printed, the color difference from a calibration target registered in the printer is calculated, and the check results are displayed. Note •This step can be executed when a printer that has a spectrophotometer unit installed is selected.•When printing the color check adjustment pattern,...
Page 793
2 Click the Settings button for Color Check in the Print- er Information dialog box. 3 Enter the color check threshold value in ΔE and click the OK button. Getting the Printer Ready 1 Confirm whether the paper to be loaded can be used for color checks. Paper for color check is paper that can be used with the Auto Adjust (High Precision) setting on the spectro- photometer unit. 2 Load the paper. (See " Loading Rolls on the Roll Holder .") →P.531 (See " Loading Rolls in the Printer...
Page 794
3 Select the White/Black Backing Plate color.Note •For the color of the White/Black Backing Plate, select the color from when color calibration was executed using thespectrophotometer unit. (See "Executing Color Calibration.")→P.782 Executing Color Check 1 Open the Color Measurement sheet. 2 Select the printer you want to execute color check on from the Printer list. Executing Color Check (Windows)...
Page 795
3 Click the Color Check button. 4 The Execute Color Check dialog box is displayed. Select Pattern Size . To increase the precision of the color check, we recom- mend that you configure the same settings as when Auto Adjust (High Precision) was executed in color calibration. (See "Executing Color Calibration .") →P.782 5 Click the OK button. iPF6400...
Page 796
6 When the Execute Color Check dialog box is dis- played, check the details. 7 Click the Execute button. The color check is executed. Note •You can exit the color check in the middle by clicking the Cancel button. However, it may take some time to end.8 Check the results. Note •We recommend that you execute color calibration if the results exceed the threshold values. (See "Executing Color Calibration.")→P.782 Executing Color Check (Windows)...
Page 797
Registering Execution Logs in Favorites Registering Execution Logs in Favorites You can register frequently used execution logs in favorites for Acquire Color Measurement Data. Registering an op- eration in favorites allows you to attach a separate name for easily recalling the operation.Note •This step can be executed when a printer that has a spectrophotometer unit installed is selected.•You can register up to 30 execution logs in the favorites.1 Select the execution log to register in favorites in...
Page 798
4 Enter the name in Name. Enter a comment in Comment if needed. 5 Click the OK button. Deleting Execution Logs From Favorites Deleting Execution Logs From Favorites You can delete Acquire Color Measurement Data execution logs from the favorites. Note •This step can be executed when a printer that has a spectrophotometer unit installed is selected.1 Click the Favorites button in the main window ( Color Measurement sheet). Deleting Execution Logs From Favorites (Windows)...
Page 799
2 Select execution log that you want to delete in Favor- ites and click the Delete from Favorites button. 3 Click the OK button. Saving Execution Logs on the Computer Saving Execution Logs on the Computer You can save Acquire Color Measurement Data execution logs on the computer. Note •This step can be executed when a printer that has a spectrophotometer unit installed is selected.1 Select the execution log to save on the computer in Ex- ecution Logs in the main window ( Color Measure- ment...
Page 800
3 Enter the file name and save. Switching Display Units Switching Display Units The units displayed in the Color Calibration Management Console can be switched between millimeters and inches. 1 Select Preferences from the File menu. 2 Select the display units in the Units sheet in the Prefer- ences dialog box and then click the OK button. Getting Audio Notification of Color Calibration Finished Getting Audio Notification of Color Calibration Finished You can be notified by sound when color...