Canon Imageprograf Ipf825 Mfp M40 User Guide
Here you can view all the pages of manual Canon Imageprograf Ipf825 Mfp M40 User Guide. The Canon manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 841
Important • The inside surfaces of Safety Cap 1 (a) and Safety Cap 2 (b) are coated with ink to protect the noz- zles. Be careful not to touch these surfaces when removing the caps. • Never touch the ink supply section (d). This may cause printing problems. • The Printhead contains ink to protect the nozzles. We recommend removing Safety Cap 2 (b) as you hold it over the Printhead package or safely out of the way to avoid spilling ink and staining your clothes or the...
Page 842
18. Close the Top Cover. Ink now fills the system. After about six minutes, the Printhead will be automatically aligned, and the printer will go online. If no paper has been loaded, a message is displayed requesting you to load paper. Important • Never remove an Ink Tank while the system is filling with ink. • If Auto Print is Off in the printer menu, the Printhead alignment will not be adjusted. In this case, adjust the alignment after Printhead replacement by accessing Advanced...
Page 843
Maintenance Cartridge Maintenance Cartridge .................................................................................................................................... 827 Replacing the Maintenance Cartridge ............................................................................................................. 827 Checking the Remaining Maintenance Cartridge Capacity .............................................................................835 When to Replace the Maintenance Cartridge...
Page 844
Replacing the Maintenance Cartridge 1. Make sure no print jobs are in progress. You can replace the Maintenance Cartridge if the Display Screen indicates the printer is Offline or if messages ad- vise you to replace the Maintenance Cartridge. If a message prompts you to replace the Maintenance Cartridge, press the OK button. Steps 2–5 are unnecessary in this case. Go to step 6 and remove the Maintenance Cartridge. Do not replace the Maintenance Cartridge during initialization...
Page 845
6. At this point, open the Maintenance Cartridge Cover. 7. Hold the used Maintenance Cartridge by the grip (a) with one hand and put your other hand under the Maintenance Cartridge to hold it firmly on the bottom, keeping it level as you pull it out. Important • Used maintenance cartridges are heavy. Always grasp the cartridge firmly and keep the cartridge lev- el during removal and storage. If you drop a used Maintenance Cartridge or store it at an angle, ink may leak and cause...
Page 846
8. Open the box, remove the plastic bag, packaging material, and Shaft Cleaner (a), and then take out the Maintenance Cartridge (b). Important • Never touch the metal contacts (a). This may damage the Maintenance Cartridge. 9. Keep the used Maintenance Cartridge level as you put it in the plastic bag. Expel excess air from the plastic bag and seal the zipper. Maintenance > Maintenance Cartridge > Replacing the Maintenance Cartridge iPF81511 830
Page 847
10. Confirm the Maintenance Cartridge is right-side up, put it in the box with the packaging material attached, and store it so that it stays level. Important • Always put the used Maintenance Cartridge back in the box and store the box on a flat surface. Other- wise, ink may leak and cause stains. • In accordance with corporate environmental protection policies, Canon collects used maintenance cartridges. Follow the instructions provided with the new Maintenance Cartridge that describe how...
Page 848
12. Keeping the new Maintenance Cartridge level, insert it all the way in. 13. Close the Maintenance Cartridge Cover. 14. Press the OK button. The printer now initializes the Maintenance Cartridge. Next, replace the Shaft Cleaner. Replacing the Shaft Cleaner Replace the Shaft Cleaner when you replace the Maintenance Cartridge. New Shaft Cleaner is included with replacement Maintenance Cartridge. Maintenance > Maintenance Cartridge > Replacing the Maintenance Cartridge iPF81511 832
Page 849
After you execute Repl. maint cart and replace the Maintenance Cartridge, a message will appear on the Display Screen requesting you to replace the Shaft Cleaner. Select Yes and press the OK button. Next, go to step 4. 1. Press the Menu button to display MAIN MENU.2. Press ▲ or ▼ to select Maintenance, and then press the ▶ button. 3. Press ▲ or ▼ to select Repl. S. Cleaner, and then press the ▶ button. 4. Press ▲ or ▼ to select Yes, and then press the OK button. After the Carriage is moved, the...
Page 850
6. Hold the Shaft Cleaner on the right side of the Carriage by the grips (a) and pull it toward you to remove it. Important • Do not touch the Linear Scale (a), Carriage Shaft (b), or Ink Tube Stabilizer (c). Touching these parts may damage them. 7. After removing the cap of the new Shaft Cleaner, hold it by the grips (a) and attach it to the Carriage. Push the Shaft Cleaner until it clicks into place. Maintenance > Maintenance Cartridge > Replacing the Maintenance Cartridge iPF81511 834