ENGLISH F-715SG SCIENTIFIC CALCULATOR USER INSTRUCTIONS E-IE-465
HOW TO USE THE SLIDE COVER..................................................... P.3 DISPLAY (2-LINE DISPLAY) .............................................\ ................... P.4 TO GET START Power ON, OFF ..........................................................\ .................. P.4 MODE Selection .........................................................\ ................... P.5 Display Formats Setting ................................................\ ................ P.6 Before Using the Calculator ............................................\ .............. P.6 INPUTTING EXPRESSIONS AND VALUES Input Capacity .........................................................\ ....................... P.7 Input Editing ..........................................................\ ......................... P.7 Replay, Copy and Multi-statements ......................................\ ......... P.8 INPUT RANGE AND ERROR MESSAGE Calculation Accuracy, Input Ranges .....................................\ ........ P.9 Order of Operations ....................................................\ ................. P.11 Calculation Stacks .....................................................\ .................. P.12 Error Messages and Error Locator .......................................\ ......... P.12 BASIC CALCULATIONS Arithmetic Calculations ................................................\ ................ P.13 Memory Calculations ....................................................\ ............... P.14 Fraction Operations ....................................................\ ................. P.15 Percentage Calculations ................................................\ ............. P.16 Degree-Minutes-Seconds Calculations ....................................\ ... P.18 Fix, Sci, Norm, ROUND ..................................................\ ............. P.19 FUNCTIONAL SCIENTIFIC CALCULATIONS Square, Root, Cube, Cube Root, Power, Power Root, Reciprocal and Pi ......................................................\ ................... P.21 Logarithm, Natural Logarithm, Antilogarithm and Log ab ............. P.21 Angle Unit Conversion ..................................................\ ............... P.22 Trigonometry Calculations ..............................................\ ............. P.23 Permutation, Combination, Factorials and Random Number Generation ......................................................\ ............... P.24 Least Common Multiple and Greatest Common Divisor ............. P.25 Quotient and Remainder .................................................\ ............ P.25 Coordinate Conversion ..................................................\ .............. P.26 STATISTICAL CALCULATIONS ...............................................\ ......... P.27 Standard Deviation .....................................................\ ................. P.29 Regression Calculations.................................................\ .............. P.29 BATTERY REPLACEMENT ....................................................\ ............ P.33 ADVICE AND PRECAUTIONS .................................................\ ........... P.34 SPECIFICATIONS .........................................................\ ...................... P.35 CONTENTS 2 Absolute Value Calculation .............................................\ ............ P.26
HOW TO USE THE SLIDE COVER Thank you for purchas ing Canon S cientif ic Calculat or. The F -715SG f eat ures sc ient if ic, sta tist ic al and other advance funct ions such as LCM, G CD, Q uot ient and Remainder Calculations, and many more. W e recommend you to read this user manual and all the important notices before start using F-715SG. And please keep this user manual with you for future use. Slide to open the cover Slide to close the cover 3
DISPLAY (2-LINE DISPL AY)Extension mark (Shows the presence of hidden formula) Status indicators Mantissa Formula (12 characters) Next or Previous page Exponent minus sign Mantissa minus sign Exponent TO GET S TAR T Power ON, OFF First time operation: 1. Pull out the battery insulation sheet, then the battery will be loaded and the calculator can be powered on. 2 . P re ss t o r e se t the c alcula to r. Power ON: When (Power ON/Clear All) is pressed. Power OFF: When are pressed. Auto Power Off Function: When the calculator is not used for about 7 minutes, the calculator will automatically power o ff. 4UBUVT*OEJDBUPST: Shift key:Alpha key hyp :Hyperbolic key M :Independent memory ST O :Store Memory RCL :Recall Memory SD :Statistic Mode REG :Regression Mode :Degree Mode:Radian Mode:Grade Mode FIX :Fixed-decimal Setting SCI : Disp:Multi-statements Display:Quotient value:Remainder value:Undo:Upper Arrow:Aown Arrow 4
MODE Selection Press to start the calculation mode selection with the following\ display: When pressing , or , you can access the next (or previous) mode selection page. The following table shows the mode selection menu: *1 Display Setup Selection options First page : Press [ab/c] or [d/c] to specify mixed fraction or improper fraction displa y. : Press [Dot] or [Comma] to specify decimal point or 3 digits separator symbols. COMP SD REG 1 2 3 OperationLCD IndicatorMode n o i t a l u c l a C l a m r o N P M O C D S n o i t a l u c l a C l a c i t s i t a t S D S G E R n o i t a l u c l a C n o i s s e r g e R G E R D e e r g e D g e D R n a i d a R d a R G e d a r G a r G X I F g n i t t e S l a m i c e d - d e x i F x i F I C S n o i t a t o N c i f i t n e i c S i c S n o i t a t o N l a i t n e n o p x E m r o N p s i D *1 Display Setup Selection MODE Selection 5
Default setting : Scientific Notation : 0 0 3 2 . 1 s t i g i d t n a c i f i n g i s 5 x10-03Exponential Notation : Norm 2 3 2 1 0 0 . 0 Fixed decimal places : 7 0.0012300 ) r e w o L ( y a l p s i D g n i t t e S y a l p s i D Operation Before Using the Calculator Check the current Calculation Mode Be sure to check the status indicators that indicate the current calculation mode (SD, REG... etc), display formats setting and angle unit setting (Deg, Rad, Gra) before starting a calculation. Return Calculation Mode to the initial setup Y ou can return the calculation mode to the initial default by pressing (Mode) Calculation Mode : COMP Angle Unit : Deg Exponential Display Format : Norm 1 Fraction Display Format : a b/c Decimal Point Character : Dot , and this action will not clear the variable memories. Initialize the Calculator When you are not sure the current calculator setting, you are recommended to initialize the calculator (calculation mode COMP, angle unit Degree, and clear replay and variable memories), and LCD contrast by performing the following key operations: (All) Display Formats Setting Example : Change the display formats for 1.23 x10-03 F-715SG can display a result up to 10 digits. Results exceed the digit limit will be automatically displayed by exponential notation format. You can enter a value in floating-decimal, fixed-decimal, or scientific notation format and display format setting only af fects the calculation results. 6
Input Capacity INPUTTING EXPRESSIONS AND VAL UES Input EditingNew input begins on the left of the upper (entry) line. As the entries are more than 12 digits, the line will scroll to the right consecutivel y. Press , to scroll the cursor within the upper (entry) line \ and you can perform input editing as needed. Example (under editing): Replacing an entry ( 1234567 1234560 ) Press or keep pressing until s k n i l b 7 Replace with 0 ) r e p p U ( y a l p s i D g n i t t e S y a l p s i D Operation 123 456 7 8 89 90 0 Deletion (1234560 134560 ) Undo (889900) Insertion (889900 2889900) Press or keep pressing until s k n i l b 2 2 is deleted Press or keep pressing until s k n i l b 8 8 and blinks alternately Insert 2, 8 still blinking Clear 889900, still blinking Resume 889900 F-7 15 S G a ll ows yo u to inp ut a s in gle c a lc u la tion u p to 79 s te p s. S ta rtin g fr o m th e 7 3rd s te p, th e c u rs o r c h an ge s fr o m [ _ ] to [ ] ■th a t n o tif y in g th e m em ory is r u nnin g low. In c ase yo u n e ed to inp ut a s in gle c a lc u la tio n w it h m ore th an 7 9 ste p s, y o u s h o uld s e p ara te yo ur c a lc u la tio n in to t w o o r m ore s e gm en ts . • • • 1234567+8899 1234560+8899 • • • 1234560+8899 134560+88990 • • • 134560+88990 134560+88990 134560+28899 134560+2 560+2889900 7
Copy Press after replayed the previous calculation expressions (statements). Multi-statements You can put two or more calculation expressions together by using a colon . The first executed statement will have [Disp] indicator; and the [Disp] icon will disappeared after the last statement is being executed. Replay , Copy and Multi-statements Replay Replay memory capacity is 256 bytes that can store calculation expressions and results. After the calculation is executed, the calculation expression and its result will be stored in the replay memory automaticall y. Pressing (or ) can replay the performed calculation expressions and results. Replay memory is cleared when you. i) Initialize calculator setting by (or ). ii) Change from one calculation mode to anothe r. iii) Press ke y. iv) Turn of f the calculator by . After deleted an input by or cleared the input by , \ icon will be shown on the displa y. Press to resume up to 79 deleted input or to undo \ the cleared segment and back to the previous displa y. If pressed ... to delete character(s) then clear the displa y, the calculator will prioritize the undo from resuming the latest cleared characters, and followed with the deleted characters continuousl y. After inserting a new data or executing a calculation command, or pressing , the calculator cannot perform the Undo function. . 7 1 9 + 8 . 0 1 2 x 5Disp . 6 1 6 + s n A . 7 1 6 + s n A : 2 x 5 : 9 . 7 1 9 + 8 Disp. 0 1 2 x 5Disp . 6 1 6 + s n A Operation 8 Display (Upper) Display (Lower)
logx, lnx 0< x 9.999999999x1099 10x -9.999999999x1099 x 99.99999999 ex -9.999999999x1099 x 230.2585092 x 0 x < 1x10100 X2 | x | < 1x1050 X3 | x | 2.15443469x1033 1/x | x | < 1x10100; x 03 x | x | < 1x10100 X! 0 x 69 (x is an integer) nPr 0 n < 1x1010, 0 r n (n, r are integers) 1 {n!/(n-r)!} < 1 x10100 nCr 0 n < 1x1010, 0 r n (n, r are integers) 1 [n!/{r!(n-r)!}] < 1 x10100 sin x Deg 0 | x | 4.499999999x1010 Rad 0 | x | 785398163.3 Grad 0 | x | 4.999999999x1010 cos x Deg 0 | x | 4.500000008x1010 Rad 0 | x | 785398164.9 Grad 0 | x | 5.000000009x1010 tan x Deg Same as sinx, except when | x | =90(2n-1) Rad Same as sinx, except when | x | = /2(2n-1) Grad Same as sinx, except when | x | =100(2n-1) sin -1x, cos-1x 0 | x | 1 tan-1x, tanhx 0 | x | 9.999999999x1099 sinhx, coshx 0 | x | 230.2585092 sinh-1x 0 | x | 4.999999999x1099 cosh-1x 1 x 4.999999999x1099 tanh-1x 0 | x | 9.999999999 x10-1 Function Input Range Calculation Accuracy, Input RangesInternal digits: Up to 16 Accuracy*: 1 at the 10th digit for a single calculation. 1 at the last significant digit for exponential displa y. Output ranges: 1 x 10 -99 to 9.999999999 x 1099 INPUT RANGE AND ER ROR MESSA GE 9
Pol(x,y) | x |, | y | 9.999999999x1049 (x2+y2) 9.999999999x1099 Rec( r, ) 0 r 9.999999999x1099 : Same as sinx | a |, b, c < 1x10100, 0 b, c < | x | < 1x10100 , Decimal Sexagesimal Conversions 0o0o0o | x | 999999o59o ^(xy) x>0: -1x10100 < y log x < 100 x=0: y > 0 x0: x 0, -1x10100 < (1/x) log y < 100 y=0: x > 0, y