Page 11
Automatic switch-off after approx.. –Laser –Rangefinder (Without measurement) Weight according to EPTA-Procedure 01/2003 Protection class (excluding battery compartment) 20 s 5 min 6.35 oz (0.18 kg) IP 54 (dust and Splash water protected) -11- A) The working range increases depending on how well the laser light is reflected from the surface of the target (scattered, not reflective) and with increased brightness of the laser point to the ambient light intensity (interior spaces, twilight). In...
Page 12
INITIAL OPERATION Protect the rangefinder against moisture and direct sun irradiation. Do not expose the rangefinder to extreme temperatures or variations in temperature. Switching On and Off To switch on the rangefinder, briefly press the On/Off button 14 or measuring button 10. When switching on the rangefinder, the laser beam is not switched on yet. To switch off the rangefinder, press and hold the On/Off/clear button 14for a few seconds. To save the batteries, the...
Page 13
-13- When switching on the rangefinder again, “M”is indicated in the display. Measuring Procedure The rangefinder offers a variety of different measuring modes that can be selected by pushing the corresponding mode button (see “Measuring Mode”). After switching on, the rangefinder is in the “length measurement mode”. Also, it is possible to select any of the four different reference points for the measurement by pushing the reference point button 1(see “Selecting the Reference Point”). After...
Page 14
-14- To select the reference point, push button 1repeatedly until the required reference point is indicated in the display. Each time after switching on, the rear edge of the rangefinder is preset as the reference point. Changing the Unit of Measure The unit of measure can be changed any time for display of the measured values, even for already measured or calculated values. For display of the current length measurement values, the units of measure shown above are available. Area and volume...
Page 15
-15- Area Measurement For area measurements, push button 5until the indicator for area measurement appears in the display. Afterwards, measure the length and the width, one after another, in the same manner as a length measurement. The laser beam remains switched on between both measurements. After taking the second measurement, the area is automatically calculated and displayed. The last individual measured value is indicated at the bottom in the display, while the final result is shown at...
Page 16
-16- To start the measurement, briefly push the measuring button 10. Move the laser back and forth over the requested target (e.g., the room ceiling for determining the plumb line) in such a manner that the reference point of the measurement (e.g., the tip of the extension pin 15) always remains at the same location. During the measurement, the current length measurement value is indicated at the bottom of the display. The minimum value is indicated at the top right in the display. It is always...
Page 17
-17- target surface is available as a reflector. Correct results are achieved only when the laser beam and the sought distance form an exact right angle (90°) (Pythagorean Theorem). In the illustrated example, the length Bis to be determined. For this purpose, Aand Cmust be measured. Aand Bmust form a right angle. For indirect length measurements, push button 11 until the indicator for indirect length measurement appears in the display. Measure the distance Aas for a length measurement....
Page 18
-18- at the bottom in the display, while the surface is indicated at the top. The laser remains switched on. Now, measure length B 2 of the second wall. The individual measuring value indicated at the bottom of the display is added to length B 1 and the sum of both lengths is multiplied with the stored length A. The total surface value is indicated at the top in the display. In this manner, you can measure any number of further lengthsB X, which are added and multiplied with length A. The...
Page 19
-19- all measuring functions. Pushing the button repeatedly deletes the individual measured values in reverse order. In the multi-surface area measurement mode, pushing button 14the first time deletes the last individually measured value; pushing the button a second time deletes all lengths B X. Memory Modes When switching off the Rangefinder, the value in the memory is retained. In the multi-surface area measur- ement mode, the total surface value can be stored; in the minimum and maximum...
Page 20
-20- Displaying the Stored Value Push the memory retrieve button 2in order to display the value stored in the memory. “M=”is indicated in the display. When the memory contents “M=”is indicated in the display, it can be doubled by pushing the memory add button 3or set to zero by pushing the memory subtract button 12. The memorized values can only be displayed in decimal feet or meters. Deleting the Memory To delete the memory contents, first push the memory retrieve button 2, so that “M=”is...