Home > Bissell > Cleaner > Bisell CleanView Ultimate Pet Multi Cyclonic 22T2E58K5E User Manual

Bisell CleanView Ultimate Pet Multi Cyclonic 22T2E58K5E User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Bisell CleanView Ultimate Pet Multi Cyclonic 22T2E58K5E User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 201 Bissell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							www.bissell.com 11
    Maintenance and care
    Replace drive belt continued
    3. Place new drive belt over motor pulley 
    and loop other end over rotating floor 
    brush in the space between the bristles. 
    NOTE: It is important that you use 
    only genuine BISSELL replacement 
    belts. Generic belts may not meet 
    the exact specifications required 
    to keep your vacuum operating 
    at its peak performance. The use 
    of unbranded belts could lead to 
    early failure of the vacuum and 
    could void your warranty. 
    4.  Pull the rotating floor brush firmly into  
    position, stretching the drive belt, and 
    place ends of rotating floor brush 
    down into the slots on sides as shown. 
    Alignment of brush ends in slots may be 
    necessary to fully insert the brush.
    5.  Turn rotating floor brush by hand several 
    times in the direction of motor pulley. If 
    properly installed, drive belt will center 
    itself on rotating brush crown.
    6.  Insert front edge of brush cover and 
    rotate into place. Snap the three latches 
    and replace the two screws.
    Replacing lightbulb
    1. Unplug the vacuum from electrical outlet.
    2.  Using a screwdriver, first remove 2 
    screws on either side of lens and pull 
    out to remove the lens. 
    3.  Remove the bulb from the socket by grasping 
    the bulb and pulling gently. Install the new 
    bulb by pushing it gently into the socket until 
    the bulb snaps into place. 
    4.  Reposition the lens place cover back 
    over headlight and reinsert 2 screws.
     
    The TurboBrush Pet tool should be 
    checked regularly for clogs or debris 
    wrapping around the brush.
    1. Remove tool from hose or front of vacuum.
    2.  Twist collar so opening is at the top and 
    lift top cover to remove.
    3.
    Motor 
    Pulley
    2.
    3.
    4.
    2.
    Maintaining TurboBrush™ Pet tool  
    						
    							www.bissell.com 
    Maintenance and care
    12
    3. Remove the brush from the belt and 
    clean debris.
    4.  Replace the brush inside the belt and 
    place ends into slots on sides as shown.  
    5.  Reposition top cover making sure to line 
    up inside tab at the front with the open-
    ing on the cover. Twist collar until open-
    ing is at the bottom to lock into place.
    Clearing clogs
    Low suction or poor pickup may be 
    due to a clog in the vacuum cleaner. 
    If you notice a change in the sound of 
    the motor, check for clogs. 
    1. Unplug the vacuum from electrical outlet.
    2.  Empty dirt container.
    3.  Check upper tank for build up or clogs.
    4.  If you notice a clog in the upper tank, 
    remove the inner cyclone (see section 
    "Cleaning the upper tank" below).  
    5.  Grasp the hose wand and separate it 
    from the hose wand base. Check for a 
    clog in the base, the wand or in the hose. 
    6.  Remove the Twist ‘n Snap hose from the 
    vacuum by turning to the left. Straighten 
    the hose and unclog with a long, narrow 
    object such as a broom handle. 
    7.  If the clog persists, follow the instructions for 
    "Checking the rotating floor brush and drive 
    belt" on page 10 and inspect the air pas-
    sageway for obstructions. 
    Cleaning the upper tank
    1. Grasp the inner cyclone and twist to the 
    left until the locking tabs stop the rotation. 
    Pull down from the upper tank to remove it.
    2.  Wipe out the inside of the upper tank and 
    the inner cyclone with a damp cloth moist-
    ened with water or a mild cleaning solution.
    3.  If you desire to thoroughly clean the fil-
    tration disk located in the upper portion 
    of the inner cyclone, hold the bottom of 
    the cyclone and turn filtration disk to the 
    right and pull up to remove.
    4.
    5.
    Maintaining TurboBrush™ Pet tool  continued
    1.
    3.
    5.
    2.  
    						
    							www.bissell.com 13
    Maintenance and care
    Troubleshooting
    Vacuum cleaner won’t run
    Possible causes Remedies
    1. Vacuum cleaner is not plugged in  1. Check electrical plug
    2.   Damaged power cord   2.  Replace as necessary by an authorized service representative.
    Vacuum cleaner and tools won’t pick up dirt
    Possible causes  Remedies
    1. Incorrect height adjustment  1. Adjust powerfoot to correct height
    2.  Hose not attached to suction opening  2. Firmly push hose wand into hose wand base
    3.   Twist 'n Snap hose not securely attached  3.  Make sure Twist 'n Snap hose is snapped into locked position
    4.  Crack or hole in hose  4. Check hose and replace if needed
    5.  Broken or worn drive belt  5. Replace drive belt, see pages 10-11  
    6.  Rotating floor brush bristles worn  6. Replace brush
    7.  Rotating floor brush jammed  7. Remove brush and clean debris from brush ends
    8.  Clog in vacuum  8. Clear clogs, see page 12. 
    9.  Dirt container full    9. Empty dirt container
    10.  Dirt container not installed properly  10. Position correctly and lock in place
    11.  Filters are dirty  11. Check pre-motor and post-motor filters
    12.  TurboBrush Pet is clogged or debris is wrapped around the brush roll  12. See pages 11-12 for Maintaining TurboBrush Pet 
    Vacuum cleaner is difficult to push
    Possible causes  Remedies
    1. Incorrect height setting  1. Adjust powerfoot to correct height setting
    WARNING:   To reduce the risk of electric 
    shock, turn power OFF and 
    disconnect plug from electrical   
    outlet before performing   
    maintenance or   
    troubleshooting.
     
    4.   The inner cyclone and filtration disk may 
    be washed using a mild detergent. Be 
    sure it is completely dry before reassem-
    bling or damage to your unit may result. 
    5.   Once cleaning is completed, reassemble 
    the filtration disk over the inner cyclone 
    by sliding it straight down on the top of 
    the inner cyclone and turning left. Be sure 
    to line up the tabs when reassembling for 
    proper installation.
    6.   To replace the inner cyclone, slide it into the 
    upper housing. Be sure to line up the inner 
    cyclone by ensuring tabs on filtration disk 
    are positioned toward the front of the unit. 
    Push the inner cyclone in and rotate it to the 
    right until the locking tabs stop the rotation. 
    Cleaning the upper tank continued
    5.
    6.  
    						
    							www.bissell.com 
    Troubleshooting
    Replacement parts 
    Accessories
    14Item 
    Part No.  Part Name
    1 303-1120  Style 7/9/10/12/14 Drive Belt (2-Pack)
    2  203-1603  Headlight Bulb
    3  203-1283  Wide Window Foot Brush Roll (gray)
    4  203-1073  Style 7/8/14 Pre-Motor Foam Filter
    5  203-6608  Style 8/14 HEPA Media Post-Motor Filter*
    Item Part No.  Part Name
    1 203-1056  Crevice Tool
    2  203-1059  Dusting Brush/Upholstery Tool
    3  203-1290   TurboBrush Pet
    4  203-1068  Extension Wand 
    5  203-1216  Twist 'n Snap Vacuum Hose (clear)
    12345
    12345
    Visible dirt escaping from cleaner
    Possible causes  Remedies
    1. Dirt container full  1. Empty dirt container
    2.   Filters missing or installed incorrectly  2.  Check pre-motor and post-motor filters for correct installation
    3.  Dirt container installed incorrectly  3. Pull out and re-insert dirt container correctly
    Other maintenance or service not included in the manual should be   
    performed by an authorized service representative.
    Thank you for selecting a BISSELL product.
    Please do not return this product to the store.             
    *The Filter Media, not the vacuum as a whole, complies with the High Efficiency 
    Particulate Air (HEPA) filter specification (EN 1822-1:2009).  
    						
    							www.bissell.com 15
    Warranty - BISSELL Cleanview™ Pet Ultimate
     This warranty gives you specific legal rights, and you may also have oth\
    er rights which may 
    vary from country to country. If you need additional instruction regarding this warranty or have 
    questions regarding what it may cover, please contact BISSELL Consumer Services by  
    telephone, or regular post as described below, or contact your local in country distributor.
    Limited One Year Warranty
     Subject to the *EXCEPTIONS AND EXCLUSIONS identified below, BISSELL Homecare, Inc., 
    will replace (with new or remanufactured components), at BISSELL’s option, free of charge 
    from the date of purchase by the original purchaser, for one year any defective or   
    malfunctioning part do to manufacturers defect. 
      This warranty applies to product used for personal, and not commercial o\
    r rental service. This 
    warranty does not apply to fans or routine maintenance components such a\
    s filters, belts, or 
    brushes. Damage or malfunction caused by negligence, abuse, or use not i\
    n accordance with 
    the User’s Guide is not covered.
    BISSELL HOMECARE INC. IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL   
    DAMAGES OF ANY NATURE ASSOCIATED WITH THE USE OF THIS PRODUCT.   
    BISSELL’S LIABILITY WILL NOT EXCEED THE PURCHASE PRICE OF THE PRODUCT. 
    *EXCEPTIONS AND EXCLUSIONS FROM THE TERMS OF THE LIMITED WARRANTY
    THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES EITHER ORAL OR 
    WRITTEN. ANY IMPLIED WARRANTIES WHICH MAY ARISE BY OPERATION OF LAW, INCLUDING 
    THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE 
    LIMITED TO THE ONE YEAR DURATION FROM THE DATE OF PURCHASE AS DESCRIBED ABOVE.
    For UK inquiries:
    Monday - Thursday  9 am — 5 pm 
      Friday  9 am — 4 pm 
    BISSELL Homecare (Overseas) Inc.
    Ground Floor 
    226 Berwick Avenue 
    Slough 
    Berkshire, SL1 4QT 
    United Kingdom  
    Telephone: 0844-888-6644   For spare parts and accessories:
    Monday - Friday 
       9 am — 5:30 pm 
    Exserve Ltd.
    550, Peterborough
    Cambridgeshire, PE2 6WH
    Telephone: 01733-362415   
    						
    							©2011 BISSELL Homecare, Inc
    Grand Rapids, Michigan
    All rights reserved. Printed in China
    Part Number 110-4355
    Rev 3/11
    Visit our website at:
    www.bissell.com
    BISSELL consumer services
    www.bissell.com 16
    If your BISSELL product should require service:Call BISSELL Consumer Services at the numbers below and we will give you the location of a 
    BISSELL Authorized Service Center in your area. For all other countries, contact your local in\
     
    country distributor for questions, service, or repair. 
    If you have questions about your warranty or need replacement parts please contact the  
    numbers below.
    Or visit the BISSELL website - www.bissell.com
    When contacting BISSELL, have model number of cleaner available.
    Please record your Model Number: ___________________
    Please record your Purchase Date:  ___________________
    NOTE: Please keep your original sales receipt. It  
    provides proof of purchase date in the event of a  
    warranty claim. See Warranty on page 15 for details.  
    For UK inquiries:
    Monday - Thursday 9 am — 5 pm 
      Friday  9 am — 4 pm 
    BISSELL Homecare (Overseas) Inc.
    Ground Floor 
    226 Berwick Avenue 
    Slough 
    Berkshire, SL1 4QT 
    United Kingdom  
    Telephone: 0844-888-6644   For spare parts and accessories:
    Monday - Friday 
       9 am — 5:30 pm 
    Exserve Ltd.
    550, Peterborough
    Cambridgeshire, PE2 6WH
    Telephone: 01733-362415  
    						
    All Bissell manuals Comments (0)

    Related Manuals for Bisell CleanView Ultimate Pet Multi Cyclonic 22T2E58K5E User Manual