Barco CR Series Projector User Manual
Have a look at the manual Barco CR Series Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 183 Barco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
www.barco.com 010201760003015D0176 the pr User Manual 010201760003015D0176 the pr 010201760003015D0176 the pr CR series User Manual 010201760003015D0176 the pr User Manual 010201760003015D0176 the pr
3 1 Contents of this User’s Guide 1 Introduction 6 1.1 Thank you 1.2 Features 2 Safety Instructions 9 2.1 SAFETY 2.2 GENERAL WARNINGS 2.2.1 INFORMATION AND WARNING ABOUT POTENTIAL HEALTH ISSUES RELATED TO MERCURY VAPOR (UHP lamps only) 2.2.2 HEAVY DUTY AND CONTINOUS USE (UHP lamps only) 2.2.3 SERVICE PERSONNEL INFORMATION WARNING (UHP lamps only) 2.2.4 REMOTE CONTROL WARNING 2.2.5 WARNING SYMBOLS 2.3 FCC 2.4 WEEE INFORMATION 2.5 ENVIRONMENTAL INFORMATION 2.5.1 Disposal Information 2.5.2 Disposal of batteries in the product 2.6 SERVICE INFORMATION 3 What’s in the box? 13 4 Getting to know the projector 15 4.1 Overview 4.2 Indicators 4.2.1 The status indicator 4.2.2 Keypad 4.2.3 Remote control 4.3 Connectivity 4.4 Graphical User Interface (GUI) 5 Basic setup 21 5.1 Lens 5.1.1 Lens and lens mount 5.1.2 Inserting a lens 5.1.3 Replacing a lens 5.2 Adjusting on screen image size and position 5.3 Lamp operation 5.4 Projector rotation english
CR series User Manual - Introduction 4 5.5 Ceiling mount 5.5.1 Ceiling mount cover (optional) 5.5.2 Attaching the ceiling cover 5.6 Connection and cables 5.6.1 Setting up a video source 5.6.2 Setting up a computer source 5.6.3 Connecting command and control interfaces 5.6.4 Attaching X-PORT™ modules 5.7 Using X-PORT™ modules 5.7.1 X-PORT DCC120 5.7.2 X-PORT 3G-SDI 5.7.3 X-PORT HDMI 3D 5.8 Image alignment 5.9 Setting image orientation 5.10 Using source scan 5.11 Limiting OSD messages 5.12 Changing the language of the menu system 5.13 Identifying system status 5.13.1 Getting information about the active source 5.14 Using the dual lamp system (UHP models only) 5.15 Configuring 3D (AS3D) 5.16 Image sizes 6 Advanced setup 35 6.1 Controlling multiple projectors with remote control ID (RCID) 6.2 Protecting the projector with a pin code 6.3 Using dual head input 6.4 Multi-channel 3D synchronization 6.4.1 Synchronous frame sequential 6.4.2 Asynchronous frame sequential 6.4.3 Synchronous side-by-side 6.4.4 Asynchronous side-by-side 6.5 Setting custom color space and digital level 6.6 Disabling IR receivers 6.7 Controlling screens with triggers 6.8 Setting aspect trigger behavior 6.9 Automatic power on/off 6.9.1 Using the timer 6.9.2 Using DPMS (Display Power Management Signaling) 6.10 Disabling LED indicators 6.11 Setting the background color 6.12 Selecting the startup logo english
5 6.13 Setting OSD menu timeout 6.14 Selecting the startup logo 7 Optimising the picture 43 7.1 Calibration data 7.1.1 Updating RealColor™ calibration data 7.2 Working with RealColor™ 7.2.1 Setting the BrilliantColor™ correctly 7.2.2 Gamma 7.2.3 RealColor™ operating modes 7.2.4 Setting a white point or color temperature 7.2.5 Defining the system color gamut 8 Maintenance 49 8.1 Software upgrades 8.2 Lamp replacement (UHP units only) 9 Technical specifications 51 9.1 Product details english
CR series User Manual - Introduction 6 1 Introduction 1.1 Thank you Thank you for purchasing this projector. When referring to the term CR-series in this document,it means that the conten\ t is applicable for following Barco products: • CRPN-62B • CRWQ-62B The CR series projectors set an industry benchmark for projectors in its size and performance category. Featuring high resolution DLP technology, high performance optics and lenses, updated signal processing and built-in frame-lock synchronisation makes it the ideal projector for multi-channel visualisation and simulation applications, whe\ re realism and reliability are key criteria. In addition the excellent image performance, the 1080p a\ nd WUXGA version are capable of Active Stereo 3D. 1.2 Features • 1080p (1920x1080), WUXGA (1920 x 1200), panorama (2560x1080) or WQ\ XGA (2560 x 1600) resolution single chip DLP® technology • Patented Dual Architecture or LED illumination system and optics • RealColor advanced colour management suite • Fail safe, hot swap Dual Lamp architecture or longlife LED illumination • Dual optomechanical IRIS for customizable brightness and contrast • Full powered horizontal and vertical lens shift, allows direct stacking • Full 12-bit colour resolution for minimised artefacting and high accuracy • BrilliantColor™ technology with six-colour processing for accurate colours • Elevated contrast levels for unmatched image dynamics • High brightness for large screen applications • Range of application specific colour wheel options • Wide range of projection lenses • Highly versatile colour management and calibration options • Built-in real time clock for timed operations • Sigma Designs™ technology video de-interlacing and processing • Economy mode for reduced power consumption and prolonged lamp life • Small and ergonomic footprint, with low weight • Direct view status monitor and lamp function indicators • Multiple video and graphics inputs for virtually any video and data sour\ ce • Dual Link DVI (330 MHz) • HDMI ver. 1.3a • LAN and RS232 for control and monitoring english
7 Symbols used in this documentation WARNING: Used to point out potential danger to people or equipment when u\ sing this product or peripheral equipment. NOTE: Used to point out essential handling requirements for the projector, which if not acted on may cause product malfunctioning. TIP: Used to give advice which benefits the projector usage or conditions related to projector performance. The specifications and functionality of this projector may change without prior notice english
9 2 Safety Instructions This device complies with safety regulations for Information Technology Equipment for use in an office environment. Before using the device for the first time, please read the safety instructions thoroughly. 2.3 SAFETY This user guide contains important information about safety precautions and the set-up and use of the projector. Please read the manual carefully before you operate the projector. 2.4 GENERAL WARNINGS Use only the cables and cords supplied with the projector or original replacement cables. Using other cables or cords may lead to malfunction and permanent damage of the unit. Always use 3-prong / grounded power cord to ensure proper grounding of the unit. Never use 2-prong power cords, as this is dangerous and could lead to electrical shock. Never open the unit. The projector contains no user serviceable parts. Refer all repairs to qualified personnel only. Make sure that no objects enter into the vents and openings of the set. Do not spill any liquids on the projector or into the vents or openings of the unit. Always remove lens cap before switching on the projector. If the lens cap is not removed, it may melt due to the high energy light emitted through the lens. Melting the lens cap may permanently damage the surface of the projection lens. Do not look into the projection lens when the projector is switched on. The strong light may permanently damage sight. Do not look into the laser beam when activate\ d on the remote control. Laser light may permanently damage sight. Do not point laser beam at people or animals. Only place the projector on a stable surface, or mount it securely using an approved ceiling- mount. Do not drop the projector. Always operate the projector according to the rotation guidelines. Operating the unit in other positions may reduce lamp life significantly, and may lead to overheating, resulting in malfunctioning. Always allow ample airflow through the projector. Never block any of the air vents. Never cover the unit in any way while running. Allow for sufficient distance\ to walls and ceilings to avoid overheating. Minimum safety distance to any side of the unit is 50 cm / 20” in any\ direction. Hot air is exhausted from the rear vent. Do not place objects that are sensitive to heat nearer than 50cm / 20” to the exhaust vent. The projector is designed for indoor use only. Never operate the unit outdoors. Do not operate the projector outside its temperature and humidity specifications, as this may result in overheating and malfunctioning. Connecting sources to a powered projector may result in product failure. It is recom- mended that the power cable connector (projector-end) or the mains power socket are accessible while the product is in use to enable mains power to be disconnected or switched off when connecting source devices. This should be considered during product installation. english
10User’s Guide - Safety InstructionsCR series User Manual - Safety Instructions Only connect the projector to signal sources and voltages as described in the technical specification. Connecting to unspecified signal sources or voltages may lead to malfunction and permanent damage of the unit. In order to prevent damage to the projector caused by overvoltages (e.g. lightning), we rec- ommend connection to a line (mains) circuit which has overvoltage protection. Allow lamp to cool down before changing. One lamp may be changed while the other lamp is operating (hot-swap). USE ONLY ORIGINAL LAMPS. 2.4.1 INFORMATION AND WARNING ABOUT POTENTIAL HEALTH ISSUES RELATED TO MERCURY VAPOR (UHP lamps only) This projector uses a very powerful UHP™ lamp for illumination to produce an extremely bright image. This technology is similar to other high-pressure discharge lamps that are extensively used in cars, street lights and other lighting appliances today. These lamps, like fluorescent lighting, contain small amounts of mercury. The amount of mercury present in a lamp is far below the limits of danger. It is very important that lamps containing mercury are treated properly to minimize potential health hazards. The UHP™ lamp, like any other high brightness projector lamp, is under high-pressure when operating. While the lamp and the projector are carefully designed to minimize the prob- ability of lamp rupture, the lamp may break while operating and small amounts of mercury vapor may be emitted from the projector. The probability of rupture increases when the lamp reaches its expected lifetime. It is therefore highly recommended that the lamp is replaced when the rated lifetime is reached. As a general precaution, secure good ventilation in the room when operating the projector. If lamp rupture occurs, evacuate the room and secure good ventilation. Children and pregnant women in particular should leave the room. When replacing a worn lamp, dispose of the used lamp carefully by proper recycling. Mercury is a naturally occurring, stable metallic element that may pose a s\ afety risk to people under certain conditions. According to the Public Health Statement for Mercury published by the Agency for Toxic Substances and Disease Registry (“ATSDR”, part of the United States Public Health Service), the brain, central nervous system and kidneys a\ re sensitive to the effects of mercury, and permanent damage can occur at sufficiently high levels of exposu\ re. Acute exposure to high concentrations of mercury vapor can cause conditions such as lung and airway irritation, tightness in the chest, a burning sensation in the lungs, coughing, nausea, vomiting and diarrhea. Children and fetuses are particularly sensitive to the harmful effects of metallic mercury to the nervous system. Seek medical attention if any of the above symptoms are experienced or if other unusual conditions are experienced following lamp rupture. 2.4.2 HEAVY DUTY AND CONTINOUS USE (UHP lamps only) The projector contains moving parts (such as cooling fans) that have limited\ life-expec- tancies. When the projector has been used for 8 000 hours, and when the unit is used in mission-critical applications, it is recommended that the projector is given preventive mainte- nance by a qualified service person. A message will appear on the screen when the projector is due for preventive maintenance. This will help ensure long term stable operation. 2.4.3 SERVICE PERSONNEL INFORMATION WARNING (UHP lamps only) Use UV radiation eyes and skin protection during servicing. english