Page 101
ERROR LOG DC Power Failed: Indicates the absence of +5 V dc on a cabinet. Each cabinet has its own power supply; therefore, this may not cause a Warm Start. DC Power Restored: Indicates that +5 V dc has been restored. The DC Fail Check log is removed. This message keeps a record of dc hits. It is possible to produce this error when a CP is inserted into a slot with power On. Down-Link Buffer Overflow: Software problem. Down-link buffer receiving messages too fast. DPR/Arch Angel Interface Test...
Page 102
ERROR LOG Electronic Power Feed Test Overload: The M lead on a tie trunk has an external short circuit. Empty CSMA Queue: (STARLAN Interface CP) This error resets the CP. If the reset is successful, then the error is transient and recoverable. If the reset fails, then the CP should be checked. Error Log Table Full: Remove entries from the Transient Error Log to free-up space. External RAM Failure: Port CP or Call Processor error while running background non-destructive external RAM tests. Check...
Page 103
ERROR LOG Illegal Port Interrupt: (STARLAN Interface CP) This error is an isolated transient condition that is normally recoverable. If this error occurs too frequently, a permanent alarm will be generated and the CP should be checked. Internal RAM Failure: Port CP or Call Processor error while running background non-destructive internal RAM tests. Check port or Call Processor CP. Internal Sanity Timeout: (STARLAN Interface CP) This error resets the CP. If the reset is successful, then the error is...
Page 104
ERROR LOG Message Corruption: (Other than CPU or Memory) Down-link message checksum error. If consistent error for particular port CP—check TDM bus drivers on the CP. If error is associated with many CPs—drivers on CPU may be bad. Also check TDM bus terminators. Message From Non-Translated Port: The port CP sent an up-link message. Translate the CP and its port or remove the CP. No Channel Buffer: (STARLAN Interface CP) This error is an isolated transient condition that is normally recoverable. No...
Page 105
ERROR LOG Physical and Logical Type Mismatch: (Other than CPU or Memory) Port CP plugged into wrong slot; change translations for slot. Port Board In Unadministered Slot: (Other than CPU or Memory) Port CP inserted into a slot that is not translated, or inserted into wrong slot. Port Board Missing But Administered: (Other than CPU or Memory) Translated port CP that CPU cannot access. Check CP slot; reseat CP; change CP; or remove CP from translations. Port Board Out Of Service: (Other than CPU or Memory)...
Page 106
ERROR LOG Received Incorrect Number Of DID Digits: This error indicates that the CO is set up to send a different number of DID digits than the switch has been administered to receive. ROM Checksum Failure: ROM checksum test has failed. Replace the CPU. Ringing Without Ground: Tip and ring on Ground Start port circuit may be reversed or may be CP problem. Also, CO may not be able to send ground. Service Circuit In Mismatched Slot: Service Circuit in slot translated for other type CP; two Service Circuits...
Page 107
ERROR LOG Translation Memory Test Failed: Memory translation checksum test failed. Reload translations from tape; check CPU; check if Cold Start error has occurred as a result of power failure problems. Trunk Call Dropped: A call that had been up on a trunk for more than 9 hours has been detected by an audit and dropped. The port associated with the error identifies the trunk in question. Trunk Call Too Long: An audit found a call that had been up on a trunk for more than 5 hours and logged this error to...
Page 108
OPERATING THE DIGITAL TAPE UNIT The Model DC4 Digital Tape Unit (DTU) or equivalent is extremely important in system maintenance. The DTU is used to store system translations, in the unlikely event that translations are lost in a system failure. This section covers the following: l l l lSetting up the DTU Saving Translations Verifying Translations Restoring Translations. Setting up the DTU The DTU must be properly connected to the system before it can be used. Refer to the Installation and Test Manual...
Page 109
OPERATING THE DIGITAL TAPE UNIT Note:The system automatically compensates for the clear leader material at the beginning and end of the tape. Saving Translations Follow these steps to save translations on tape: 1. 2. 3. 4. 5. 6. 7. Complete the steps in the preceding Setting up the DTU section. Press both the RECORD and PLAY buttons simultaneously. (The unit should not yet begin to run.) Log on to the SAT, if not yet logged on. The system displays the main menu prompt: Make one selection from menu ->....
Page 110
OPERATING THE DIGITAL TAPE UNIT 8.Press the STOP/EJECT button on the unit. 9.Press the REWIND button and rewind the tape fully. 10.Verify the translations saved on the tape, following the steps in the next section. Verifying Translations Always verify the translations saved to tape because of the possibility of faults with cassettes or equipment. Successful completion of the Verify function assures that saved translations match exactly the translations in the system. CAUTION: Performing the Verify...