23602/13 1 B.Disassembly There are some parts which have to be taken off with careful treatment. 1.Top cover (A300) removal Wind lever should be set at closed position before taking off top cover. 2.Photo sensor circuit board assembly (T300) removal K2 camera is controlled with very small electric current (ex. 200pA or 300pA), therefore all electric parts should be treated carefully, especially, photo sensor circuit board; it is so sensitive that it should not be touched with bare hands.AT PREADVANCE...
Page 3
23602/13 2 3.P.C. board attern assembly (T100) removal P.C. board pattern assembly (T100) can be taken out with or without removing Front Board. Pull it out hooking the large black I.C. with spring hanger. Dont touch the other I.C.s or electric parts. 4.Front board removal Front board can be removed without taking off Self-Timer lever or covering, as shown in photograph. 5.Shutter mechanism (E000) removal Shutter mechanism (E000) is so delicate and sensitive that it should not be touched with bare hands...
Page 4
23602/13 3 C. Assembly and adjustments Some parts should be assembled and adjusted. with careful treatment as shown in the following. 1.Winding stopper assembly (0-C6) 2.Winding spring (0-C23) Face the retainer screw of spring in the direction of Tripod socket, and wind the spring a little and stretch it in the direction of tripod seat. The proper tension is obtained when it is stretched around Tripod socket 3.Perforation Adjustment There are several kinds of 2nd gear (C205) which are selected to...
Page 5
23602/13 4 Wind up top 2nd mech. plate assembly (C200) with driver and loosen wind shaft without moving main gear. Then give back-tension to sprocket gear (C16) Choose the proper coupling 2nd gear (C205) and install it in the above-mentioned way. 4.Memory block assembly (T400) After cocking mirror housing, 02mm clearance is necessary between delrin and the longer contact piece of memoiy block (T400) — See Fig. 12 A After releasing mirror housing and when mirror stays up, also 02mm clearance is necessary...
Page 6
23602/13 5 6.Blue needle adjustment (a)Set shutter dial to “AUTO”. Install Idle gear holder assembly (0-A12) gearing 2/3 portion with the gear of (ga1vanometer (q 1) Idle gear holder assembly (0-A12) should never touch shaft recept~cle assembly (0-D5), and the clearance is approximately 0.2-0.3mm. (b)Pull meter coupling plate assembly (0-A8) toward shaft receptacle assembly (0-D5). Install rack (A11), attaching its concave part to the rivet of meter coupiing plate assembly (0- A8). Three kinds of rack...
Page 7
23602/13 6 Procedure (a)No clearance is allowed between release plate (A503) and the lever of shutter mechanism (E000). and also the lever should not be pushed by release plate. (b)After shutter cocking, adjust clearance to 0.3mm between Mirror Actuator lever hook plate assembly (0-B48) and its hitting part. (Adjusting screw 1) (c)Shutter stroke adjustment Depressing shutter button gradually, shutter starts working at 2.3mm ±0.2 deep from original position. (Adjusting screw 2) (d)Self timer stroke 0.1 mm...
Page 8
23602/13 7 9.Shutter speed adjustment: Testers:Light value correction unit. TSST-3A. T adjuster (or battery), ESST-1A, digital counter, diaphragm setting ring (KA-00-lA), 23600K-A400-A. Procedure: (a)Auto speed adjustable resistor R7 (1X, ASA100, 2.8V) EV12—1/60 sec EV16—1/1000 EV16(2X)—1/500 EV8—1/4 EV4—1 (b)Meter level — R10 EVI6—1/1000sec (c)Meter sensitivity — R9 EV8—1/4 (d)Manual shutter speed — Rl2 EVI2—1/60 (check all shutter speeds to see Rotary SW contact effects) (e)Battery Checker 2.1VOFF...
Page 9
23602/13 8 10.Galvanometer installation Tester:Meter tester (MA-00-01) Needle must be absolutely horizontal between 15 and 8. Check the movable range of the needle in the upper and lower part. 11.Shutter release adjustment As shown in Fig. 19, when mirror .housing is released, dimension between Shutter Actuator plate (B61) and minor housing foot. should be kept at 9.4 ±10mm. The longer Shutter actuotor plate (B61) will break Shutter mechanism (E000), and the shorter one will never make it (E000)...
Page 10
23602/13 9 D.Lubricants G21—Mainly used G31—0-B25, 0-B48, 0-B68, 0-B22 L—On rewind shaft (D6) E. Special tools 23600K-C135-A 23600K-A316-A 23600K-A340-A 23600K-A19-A 23600K-C8-A 23600K-B40A 23600K-D4-A 23600K-C134-A1 23600K-C134-A2Fig. 20