AOR SDU5600 Spectrum Display Unit Operating Manual
Here you can view all the pages of manual AOR SDU5600 Spectrum Display Unit Operating Manual. The AOR manuals for Communications receiver are available online for free. You can easily download all the documents as PDF.
Page 31
31 5-7 Waterfall display facility The SDU5600 is equipped with a waterfall facility which can display the variation of signal strengths in conjunction with the time lapsed (as sweeps progress). Sixteen different colours are employed dependant on signal strength, in the shape of a waterfall. Press the FUNC + ˜ to start the waterfall display. The bottom half of the screen will be allocated to the waterfall display and will build-up with time. The waterfall display continues to operate being unaffected by...
Page 32
32 5-8 On/off of the displayed information The companion receiver parameters are usually displayed on the left side of the LCD graticule. The key sequence FUNC + 5 (DISP) will toggle the display of the companion receiver’s parameter on / off. When the calculation mode is in use, the calculation data will be turned on or off by the same key-in sequence. By effective use of this facility, you can view the signal activities easier on the much less cluttered display area. 5-9 Beep alert To toggle the...
Page 33
33 6. Operating the SDU5600 This section will provide examples of operating the SDU5600 using the AR5000A+3 as companion receiver. Refer to pages 10 to 12 of this manual for connection to the receiver. Section 6, 6-1 6-1 Operate the SDU5600 with the AR5000A+3. Turn the SDU5600 on, which is followed by the opening message to confirm for readiness. Access the configuration menu by pressing the FUNC + 4 to select the companion receiver. Press the RX key, which displays the current companion radio type...
Page 34
34 6-2 Monitor the VHF FM band in the spectrum analyser mode Continue to operate the SDU5600 from section 6-1 where the SDU5600 / AR5000A+3 has been set in the spectrum monitoring mode. The example to the right is the actual result which was obtained after monitoring the signal spectrum at the AOR headquarters in Tokyo. It indicates the input signal being saturated, resulting in some weak ghost signals appearing at regular intervals close to the floor level of the spectrum trace. Adjust the input...
Page 35
35 6-3 Monitor the FM broadcast band in the step resolution mode The following information explains how to change the monitoring mode from the default of spectrum analyser mode to the step resolution mode. Press the FUNC + 2 (STEP), the SDU5600 will shift to Step Resolution mode with the legend StepReso. appearing on the LCD. The display step will be unchanged at this stage. You may wish to change the display step to a 25kHz in order to make the task of monitoring easier. Press the SPAN/STEP key,...
Page 36
36 6-4 Monitor the VHF air band in the channel scope mode. The VHF airband is allocated over the wide frequency band, It is therefore impossible to display the entire VHF airband on the SDU5600 at once. The channel scope mode however provides a very convenient method of monitoring the channelised frequency band through the use of both the marker and receive marker. Using this method, you can split the airband into small sections for quick inspection. Change of the monitoring mode To change to Channel...
Page 37
37 6-5 Suitable applications of each monitoring mode A summary of the three monitoring modes and suitable applications is given here: Spectrum analyser mode This mode is the DEFAULT and most common monitoring mode among the three. It is suited to the monitoring of permanent or intermittent signals or noise. The CF (centre frequency) and SPAN (visible bandwidth) are the main criteria to be specified. Step resolution mode This mode is suited best to monitor signals which are allocated with certain...
Page 38
38 7. Useful Information The SDU5600 has been designed to operate with a wide-band companion receiver such as the AR5000A. Therefore, there are some differences in operating characteristics with the unit when compared with the spectrum analysers which are designed for more general testing / measuring applications. It is advisable that you take into account the following information while making yourself familiar with the SDU5600. Signal strength The signal strength which the SDU5600 indicates is measured...
Page 39
39 8. SDU5600 Command List The SDU5600 can be operated via PC using the RS232 port. 8-1 Communication parameter and connecting lead The SDU5600 and a PC should be connected using a straight cable between the [PC I/F] socket and the serial port of the PC. The SDU5600 port is MALE, so the PC lead must have a female connector or a gender changer will have to be employed. Communications parameters of the SDU5600 Baud rate 9600bps Data length 8 bit Parity None Stop bit 2 bit Flow control RTS/CTS 8-2...
Page 40
40 8-3 Basic format of the command Each command to be sent to the SDU5600 consists of 4 letters (upper case) in ASCII code with appropriate parameters followed by . Each letter represents the following: (1) First letter Either W for write or R for read (2) Second letter Line of command such as S for spectrum analysis, V for visual set-up, U for user interface and I for information (3 & 4) Third and Fourth letter Categories of each line of command 8-4 RS232 command list Commands are divided into four...