    NOTES for the SDU5000 (Rev 1.3)
1. First ensure that the receiver is switched On and connected to the SDU5000.  The SDU ROM will
permit operation with the AOR AR3000A, ICOM IC-R7000, IC-R7100, IC-R9000 and as a band scope
with other receivers with a 10.7 MHz I.F. output such as the AOR AR3000 (a small modification is
required to the AOR receivers in order to provide compatibility).
If using an ICOM receiver, the CT17 optional interface will be required.  The ICOM receiver must be
configured for...

Page 29

Of course you can work the formulae backwards too!  If you require a 5kHz step:
5 x 16 x 10 = 800 kHz  - you may note a quick way: simply divide or multiply by 160
(the total number of increments)
The following relative table may be of assistance:
Each marker movement Bandwidth (span)
1 kHz 160 kHz
5 kHz 800 kHz
6.26 kHz 1000 kHz
9 kHz 1440 kHz
10 kHz 1600 kHz
12.5 kHz 2000 kHz
20 kHz 3200 kHz
25 kHz 4000 kHz
50 kHz 8000 kHz
62.5 kHz (maximum span) 10000 kHz
8. Due to the AGC effect of the host receiver,...