Page 11
Page 11 MPSet memory channel as pass To set: MPn n = 0 (pass off), n = 1 (pass on) To read: MP (when in memory read mode) Note: Setting pass on a memory channel excludes it from scans Note: “?” is returned when not in M.RD mode MQDelete bank or memory channel MQ Deletes the current memory channel (when in memory recall mode) MQ nn Deletes memory channel nn MQx%% Deletes all memory channels from bank x. Note: Responds with “?” when a memory channel is protected. Refer to PC, WM and WP commands MRRecall...
Page 12
Page 12 NLNoise Limiter To set: NLn n = 0 (off), n = 1 (on) To read: NL Response is NL n OFSelect offset frequency OFnnx Selects offset frequency at index nn (00-47, 00=off) and defines offset to be x (+/-) OF Returns with the current offset frequency data as follows: OF mmx RF0nnnnnnn00 (where mm is the offset index value and x is + or -) Notes: 1. OF can be used on its own or with MX and SE 2. Allows access to a table of offset frequencies defined by OL 3. Automode operation is switched off when...
Page 13
Page 13 PPSet priority channel To set: PPxnn Selects channel xnn as the priority channel, where x is a bank A-J or a-j and nn is a channel number To read: PP Responds with PP xnn PQWait time for LC2 To set: PQnn Sets time nn (00-99 corresponding to 000-990 mS in steps of 10 mS) To read: PQ Responds with PQnnn (000-999 mS) Note: This wait time is used as a buffer. PRList pass frequencies PRxnn Lists the pass frequency stored in pass channel nn of bank x (A-T, a-t or V) PR x Lists all pass frequencies...
Page 14
Page 14 RXRespond with current data RX Recalls current operating parameters in the following formats VFO mode VF RF nnnnnnnnnn STnnnnnn AUn MDn ATn 2-VFO mode V x RFnnnnnnnnnn STnnnnnn AUn MDn ATn VFO search mode VS V x RFnnnnnnnnnn STnnnnnn AUn MDn ATn VFO scan mode VV V x RFnnnnnnnnnn STnnnnnn AUn MDn ATn Memory manual mode MR MX xnn MPn RFnnnnnnnnnn STnnnnnn AUn MDn ATn TMxxx...x Scan mode MS MX xnn MPn RFnnnnnnnnnn STnnnnnn AUn MDn ATn TMxxx...x Select scan mode SM MX xnn MPn RFnnnnnnnnnn STnnnnnn...
Page 15
Page 15 SHSet offset step To set: SHnnnnm0 Set the tuning step size in Hz To set: SH nnn.nm Set the tuning step size in kHz SH+ nnnnm0, SH+nnn.nm or SH+ turns on step adjust m is either 0 or 5 To read: SH Responds with value, format: SH nnnnm0x (x=+ step adjust on) SIVoice Invertor on/off Note: Requires VI8200 To Set: SIn n=0 (off), n=1 (on) To read: SI Responds with SI n SCnnn Example: SI1w SC051 when the invertor value is 051 Note: Refer to individual commands for details of each field. SLLower search...
Page 16
Page 16 TBSet Text Description for Bank To set: TBnxxxxxxxx Sets the text for bank n (A-J or a-j) to be the 8-character ASCII comment specified TB or TB%% Responds with a complete listing of the comments for each bank in the following form: TB MW A:50 TBAAOR Test MW a:50 TBa MW B:50 TBBAOR MW b:50 TBb MW C:10 TBCAOR Test MW c:90 TBc MW D:50 TBDAOR Test MW d:50 TBd MW E:50 TBE MW e:50 TBe TB x Responds with the text for bank x in the following format: TBA TBAAOR Test TISet priority interval To set: TI...
Page 17
Page 17 VTVFO auto-store To set: VTn Where n is defined as follows: 0 Off 1 On, Auto-store to bank J 2 On, erase bank J To read: VT Responds with VT n as above Note: VT2 response is equivalent to VT1 VVVFO Scan To set: VVn Where n=0 (2-VFO mode) or n=1 (VFO scan mode) WMWrite Protect Bank To set: WM xn Where x is bank (A-J or a-j) and n=0 (protect off), n=1 (protect on) To read: WM or WM%% Responds with a listing of 10 banks starting from the last queried bank. Example: WM WM F0 WM f0 WM G0 WM g0 WM...
Page 18
Page 18 Up/DownIncrementn where n is a binary byte value as follows ð0x1c ï0x1d ñ0x1e ò0x1f (8) AOR PC Windows control software & bandplan editing A dedicated PC Windows package is supplied on CD-ROM with the CC8200 lead, it is also available as a FREE download from the AOR web site WWW.AORJA.COM It is recommended that the AOR software be used should you wish to edit the automode bandplan data. The protocol information for bandplan has not been included in the CC8200 command listing as errors...
Page 19
Page 19 Installing the software To install the AOR software run the INSTALL.EXE program from the CD-ROM ( x:\English\CC8200\cont-soft\install.exe where ‘ x’ is your CD-ROM drive letter). If installing from a web download, expand the ZIP file into a temporary directory on your hard drive then run the INSTALL.EXE A directory will be created on your hard drive along with a program group from the START/PROGRAMS button of the desktop. This software package will also provide additional facilities such as...
Page 20
Page 20 CC8200 - AR8200 REMOTE CONTROL Thank you for purchasing the CC8200. This CD-ROM is supplied with the CC8200 and contains the following data in both Japanese and English languages. Should you wish to use English language, please select the files under , should you wish to use Japanese language, please select the files under . CD-ROMreadme-j.txt Read me file in Japanese language readme-e.txt Read me file in English language (this information sheet) Adobe ® Acrobat® Reader AR8200 bandplan...