Page 21
AR7030 OPERATING MANUAL PAGE 21 RF / IF menu - the LCD will show Gain above the spin-wheel, but this is IF gain (see section 6-11) - the RF gain setting is shown in the centre of the display between up and down arrows. For example < RF+00 > indicates the normal setting. Pressing the buttons below the up or down arrows changes the RF gain setting. The value displayed is actually the maximum value that the receiver will use. Unless specifically disabled (see section 9-4) the RF gain will be...
Page 22
PAGE 22 AR7030 OPERATING MANUAL indicating this as the spin-wheel function. When the spin- wheel is turned, the squelch level (as a percentage) will be displayed at the top left of the LCD for about 5 seconds. When the squelch level is advanced above the current signal strength, a reversed S is displayed to the left of the frequency readout. The VFO menu is split into two parts - each can be selected using the or soft-keys. In the second part of the menu there is a soft-key labelled Mut...
Page 23
AR7030 OPERATING MANUAL PAGE 23 From the above illustration, pressing the soft-key again would produce: 7-3 Dual VFO operation The AR7030 can implement a scanning system between the two VFOs termed DUAL VFO operation. This facility is more versatile than the memory scanning (section 8) because each VFO can have individual volume, delay and hold characteristics. This can be especially useful for automatically checking for activity on an amateur band net frequency or for checking international...
Page 24
PAGE 24 AR7030 OPERATING MANUAL 7.Finally activate dual VFO by pressing the soft- key. Scanning can be stopped by pressing this key again. Whilst scanning you can go to either VFO menu (using the and soft-keys) and display the S-meter (using the button) - selecting any other menu will stop scanning, but leave all items set up ready to start again when required. The receiver will monitor the second VFO for 1 second every 15 seconds. Should the VFO containing 5680kHz become active, the HOLD...
Page 25
AR7030 OPERATING MANUAL PAGE 25 you wish this frequency to be overwritten, press . If you want to keep memory 12 unaltered, then choose another memory before storing. The next or previous memories can be selected using the or keys (then ), or a new memory number can be keyed in. From the front panel choose the MEMORY menu - use and . The current memory number Mxx is displayed above the spin-wheel, and a preview of the memory frequency displayed above that. Use the spin-wheel to select the...
Page 26
PAGE 26 AR7030 OPERATING MANUAL Mxx The memory number displayed before the arrow is the first channel of the block of memories to be scanned. Pressing the soft-key allows the spin- wheel to modify this (spin-wheel legend is From). Mxx The memory number displayed after the arrow is the last channel of the block of memories to be scanned. Pressing the soft-key allows the spin-wheel to modify this (spin-wheel legend is To). SQUELCH Sets the minimum signal level that will stop the scan (if...
Page 27
AR7030 OPERATING MANUAL PAGE 27 5.Start the scanning process with the soft-key (the bullet will be filled when scan is running). The memory channel currently being monitored is shown above the Scan legend. Press again if you want to stop the scan. The squelch threshold can be adjusted for each of the memories (if necessary) during this first scan pass. When the squelch level is changed the new value will automatically be stored in the memory channel whilst the scan is active. Also the scan...
Page 28
PAGE 28 AR7030 OPERATING MANUAL 9 Setup, Timer and Config menu options The SETUP menu allows access to the three receiver setup memories: A, B and C. The CONFIG menu allows various manual / automatic options to be set and the auxiliary output levels adjusted. It is also the route to the filter calibration routine. Both of these menus differ from all of the other receiver menus in that item selection is made by rotating the spin-wheel. Both menus have eight items so it doesn’t take too long to...
Page 29
AR7030 OPERATING MANUAL PAGE 29 The sleep time will count down to zero, when the radio will switch off. The receiver can still be tuned, modes changed and volume adjusted. To cancel the sleep timer press the or buttons. The sleep timer is synchronised to the clock so that it changes when the clock seconds are at zero. For this reason one minute is added to the run time so that the set doesn’t switch off too soon. Setting the timer for automatic switch-on: The switch- on timer is set in 24-hr...
Page 30
PAGE 30 AR7030 OPERATING MANUAL Item Settings SelectNone (Modify is informative legend for the soft-keys) Aux relay: Off Timer Squelch Aux output muting: Off On Aux o/p (L): 0% (off) to 99% (max) Aux o/p (R): 0% (off) to 99% (max) Sync detector:AutoNarrow Wide RF Gain:Auto Man Filter calibrate: Start (pressing either soft- key starts the automatic calibration process) All settings take effect immediately the soft-keys are pressed, so the aux relay will switch on and off as its settings...