    8.1 Video output 
     
    PAL and NTSC composite output is switchable via the rear panel video switch.  
    When PAL format is selected the built-in LCD display will be inoperative.  Video 
    output is available via the rear panel video PHONO socket. 
     
     
    8.2 Audio output 
     
    Constant audio output is available via this PHONO socket, a load impedance of 10k 
    OHMS is assumed for constant level output. 
     
     
    9 RS232C 
     
    The AR7000 can be operated remotely by a personal computer via the RS232C 
    socket.  A separate RS232 command list may be available from the AOR web site or 
    head office.  First check 
    http://www.aorja.com or contact Kiyo Oshima at AOR Ltd, 
    Japan for further details. 
     
      AR7000  PC 9-way  PC 25-way 
     2  2  3 
     3  3  2 
      5  5  7  (GND) 
     7  7  4 
     8  8  5 
     
    When making an RS232 cable, always use good quality screened cable to minimise 
    noise. 
     
     
    10 AUX 
     
    A rear panel 270° 8-pin DIN socket provides the following signals:- 
     
     Pin No.  IN/OUT  Signal  Description 
       1         Out          +12V           +12V, 10mA output 
       2          -            GND           GND 
       3         In           Mute input     5V TTL 
       4         NC            NC            NC 
       5         Out          AF out         Tape Rec 10k ohm 
       6         Out          Rec out        SQ operated switch 
       7    Out          Rec out        SQ operated switch 
       8         NC            NC            NC 
     
     
    11 Infrared remote controller 
     
    The AR7000 can be operated via the supplied infrared remote controller.  Aim the 
    front of the remote at the front panel IR sensor to the AR7000.  Most IR keys mimic 
    those of the AR7000 and menus.  The IR [POWER] key is valid 
    only when the power 
    switch of the receiver is switched on (depressed).  The IR uses 2 x AAA batteries,  
    						
    							 
      check the condition of the batteries regularly to avoid damage due to leakage from 
    exhausted batteries. 
     
     
    12 Reference data 
     
    12.1 Specification 
     
    Frequency range    100kHz - 2000MHz 
     
    Receive mode    FM (W), FM (N), AM, CW, USB, LSB 
     
    Receiver circuitry   Triple superheterodyne & digital conversion 
     
    IF frequency    1st=275.4MHz,782.28MHz,  
       2nd=45MHz, 3rd=10.7MHz 
     
    Step size    10Hz - 1MHz in a 10Hz increment 
     
    Sensitivity (uV) 
    typical 
     Range    AM  CW/SSB  NFM  WFM 
     100kHz - 700kHz 4.2 1.6 4.0 - 
     700kHz - 20MHz 3.5 1.5 2.0 - 
      20MHz - 1200MHz  1.3  0.5  0.56  1.3 
     1200MHz - 2000MHz 4.0 2.0 1.6 3.5 
     
    Selectivity 
      Bandwidth     Mode      Pass band (-3dB)     Stop band (-50dB) 
     50Hz CW  75Hz   330Hz 
     150Hz CW  200Hz   680Hz 
     250Hz CW  330Hz   920Hz 
     500Hz CW  550Hz   1050Hz 
     800Hz CW  880Hz   1650Hz 
     2kHz  SSB  2150Hz    2900Hz 
     2.5kHz  SSB  2650Hz    3450Hz 
     3kHz  SSB  3150Hz    3950Hz 
     3kHz  AM  3650Hz    5000Hz 
     6kHz  AM  6650Hz    8000Hz 
     8kHz  AM  8700Hz    10kHz 
     15kHz  NFM    25kHz -40dB 
     150kHz  WFM    650kHz -20dB 
     
    IF shift       +/-8.5kHz (max) at 100Hz step 
     
    Audio filter    2.5 / 3kHz (NFM 
       7.5kHz (WFM) 
     
    CW tone    400 / 600 / 800 Hz 
     
    Audio output    1.0W (8 OHM THD 10%) 
     
    Power requirements  12V (+15%, -10%) 
     
    Current consumption    1.5A (at 1.0W audio)  
    						
    							 
                                  0.1A (switched off) 
     
    Memory 
         Memory channel      1500ch (15 bank x 100ch) 
      Program search      8 
         Program scan        8 
         Program timer       5 
         Clock               5 
     
    Scan/search rate    20ch/sec. 
     
    In/output 
      Aerial connector  50 OHM BNC 
      Video output    75 ohm  PAL/NTSC composite (PHONO) 
      Audio output    10 k ohm demodulated output 
      External speaker  8 OHMS 3.5mm jack 
      Headphones   32 OHMS (nominal) 3.5mm jack 
      AUX         Motor On/Off output  less than 300mA AC/DC 
      Rec output      more than 10 k ohm 
      Mute             TTL or contact signal 
      +12V out         less than 10mA (in line with main switch) 
      RS232C port   9 pin 9600 bps 
      Remote controller    Infrared type (1 line) 
     
    LCD display       3.1 colour LCD 
     
    Operating temperature  0 to +40°C 
     
    Dimensions (mm)                 220 (W) x 90 (H) x 240 (D) excluding projections 
     
    Weight   3.5kg 
     
    Supplied accessories    AC adapter, IR remote controller, Handbook 
     
    All specifications/data subject to change without notice due to continuous 
    development of the product.  E&OE. 
     
     
    12.2 memory channel default data 
     
    The AR7000 memory banks may contain data for test purposes during manufacture 
    of the receiver. 
     
     
    12.3 Trouble shooting 
     
    1.  No operation 
     
    ‘Check that power is connected to the AR7000 and the power switch is on 
    (depressed). 
     
     
    2. No display 
      
    						
    							 
      ‘Providing the AR7000 is powered, ensure the rear panel PAL/NTSC slide switch is 
    set to NTSC otherwise the internal display will be disabled. 
     
     
    3. Inoperative keys 
     
    ‘Ensure that the “Lock” legend is not displayed in the lower-left corner of the LCD, if 
    it is, press the [K.Lock] for more than one second to toggle key lock off / on. 
     
    ‘The primary function of keys requires a very short press (tap), if you hold them too 
    long you may activate the second function or the keys may appear to be inoperative. 
     
    ‘If you get stuck in a particular menu (and the [ESC] key doesn’t help), it may be 
    worth switching the unit off, count to five then switch it back on again. 
     
    ‘In the case of the infrared controller, ensure that the batteries are in good condition 
    and the front on the controller is pointed directly at the AR7000 IR front panel sensor. 
     
     
    4.  Poor performance 
     
    ‘Ensure that you have selected an active frequency and are using an appropriate 
    receive mode and IF bandwidth, ensure that excessive IF SHIFT has not been 
    applied. 
     
    ‘Check that the squelch control is not fully advanced, set it temporarily to “OPEN” 
    and try again. 
     
    ‘Ensure that a suitable aerial is connected to the BNC aerial input and no short 
    circuits exist in the coaxial cable or plugs. 
     
    ‘Check to see if the “ATT” legend is displayed near the top right of the LCD, if it is, 
    the receive performance will be reduced.  Press the [ATT] key for more than one 
    second to disengage the attenuator. 
     
     
    12.4 Optional accessories 
     
    ‘DA3000 
    Wide band VHF/UHF 16 element discone aerial with frequency coverage from 
    25MHz to 2GHz.  Supplied with 15m of coaxial cable terminated in a BNC plug. 
     
    ‘SA7000 
    Two element passive wide band aerial.  The VHF element is 0.7m and the HF 
    element is 1.8m in length.  Frequency coverage is 30kHz to 2GHz.  Supplied with 
    15m of coaxial cable terminated in a BNC plug. 
     
    ‘MA500 
    Mobile magnetic mounted aerial with frequency coverage from 25MHz to 1300MHz.  
    Supplied with 4m of coaxial cable terminated in a BNC plug. 
     
    ‘LA320  
    						
    							 
      Table-top active short wave loop aerial.  Supplied with two elements as standard 
    covering from 1.6MHz to 5.0MHz and 5.0MHz to 15MHz.  Operates from internal 9V 
    battery.  Supplied with BNC to BNC coaxial patch lead. 
     
    ‘LA320M 
    Low frequency 
    optional element for the LA320 active loop aerial system.  Frequency 
    coverage is 200kHz to 540kHz. 
     
    ‘LA320M 
    Medium frequency 
    optional element for the LA320 active loop aerial system.  
    Frequency coverage is 540kHz to 1.6MHz. 
     
    ‘ABF125 
    Airband filter for the VHF band 108 to 136 MHz.  Fitted with BNC male/female 
    connectors. 
     
     
    12.5 After sales service 
     
    There are no user serviceable parts inside the AR7000.  In the unlikely event of 
    failure, first check through the suggestions listed in section 12.3 of this manual.  If the 
    problem persists, please contact your supplier who will advise you of the after sales 
    procedure. 
     
      
    						