Home
>
Anetsberger Brothers
>
Fryer
>
Anetsberger Brothers Filtration System FM18 Filter Mate under fryer User Manual
Anetsberger Brothers Filtration System FM18 Filter Mate under fryer User Manual
Here you can view all the pages of manual Anetsberger Brothers Filtration System FM18 Filter Mate under fryer User Manual. The Anetsberger Brothers manuals for Fryer are available online for free. You can easily download all the documents as PDF.
Page 1
1 L20-386 R1 Anets, Inc. PO Box 501 Concord, New Hampshire 03302-0501 Tel: 603-225-6684 • Fax: 603-228-5231 GoldenFRY Models FM-14 Filter Mate FM-18 Filter Mate Model Filt II-14W shown banked to (2) 14” fryers Model FM-14 Filter Mate shown under the base system of (2) 14” fryers DANGER Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance...
Page 2
2 L20-386 R1 TABLE OF CONTENTS Shipping Container Inspection ....................................................... 2 Code Requirements ...................................................................... 2 Filter Unit Preparation Instructions ................................................ 3 Filter System Diagrams .................................................................. 4 Filtering Instructions ...................................................................... 5 Oil Disposal...
Page 3
3 L20-386 R1 INSTALLATION This Manual will detail the Installation and Operation of the Filter-Mate system, with notes where the Filtronic II System differs. Both the Filter Mate and Filtronic II Systems enable the user to safely and efficiently filter the cooking oil or shortening from a fryer in a banked row while the other fryers in that row are still being used. Even though these two Filtration Systems are slightly different in physical dimensions and design, the Installation and Operation...
Page 4
4 L20-386 R1 FILTER MATE TANK Filter envelope clip Lift out handle Quick connect coupling Knurled retaining nut Pump quick-connect coupling Filter envelope Return line and optional hose connection FILTRONIC II TANK Pump quick-connect coupling Filter envelope Filter envelope clip Lift out handle Quick connect coupling Knurled retaining nut
Page 5
5 L20-386 R1 FILTERING INSTRUCTIONS WARNING FILTERING 1. Before filtering the shortening in a fryer, turn the thermostat knob to “OFF” or the Gas Valve to “PI- LOT” to prevent the fryer from re-lighting during filtering On some models the system automatically prevents the burners from lighting when the door of the fryer is open. 2. Open the drain valve (black handle) on the fryer to be filtered, letting all the shortening drain into the filter tank. Leave this valve open. ! ! Never...
Page 6
6 L20-386 R1 Note On Using Filter Powder If filter powder is being used, add 1 cup of powder (for 14” fryers) or 2 cups (for 18” fryers) to either the fry tank or the filter tank. If added to fry tank, make sure powder is completely flushed during fry tank cleaning (Step 3) before closing drain valve (Step 4). If added to filter tank, the powder will be removed when the filter envelope is changed and the filter tank is cleaned. 6. On gas-operated thermostat models (14G, 14GS, MXEG, 18EG,...
Page 7
7 L20-386 R1 REPLACING THE FILTER PAPER If the filter paper becomes torn, or if the time to filter the oil from one unit becomes excessive, it is time to replace the Filter Envelope. 1. Disconnect the oil return line from the pump. 2. Unplug the cord from the receptacle on the side of the cabinet. 3. Pull the filter unit from the cabinet. 4. Disconnect the line from the pump to the filter screen. 5. On the Filtronic II models, pivot the motor assembly up out of the way. 6. Remove...
Page 8
8 L20-386 R1 SYSTEM TROUBLESHOOTING GUIDE SOLUTION 1. Make sure the power cord is plugged into the receptacle in the cabinet and the main power cord from the system is plugged into the appropriate power supply. 2. Turn the switch on the side of the filter to “ON”. 3. Close the return line valve (yellow handle) and try opening the return line valve on another fryer. If the pump starts, the problem is with the micro switch that contacts the return line valve on the first fryer. 4. If pump...
Page 9
9 L20-386 R1 ORIGINAL EQUIPMENT LIMITED WARRANTY General Warranty Anets, Inc. warrants to the original user of its commercial cooking appliances and related equipment that said appliances and related equipment will be free from defects in material and workmanship under normal use for a period of one (1) year from the date of installation, with appropriate documentation, to a maximum of fifteen (15) months from the date of...
Page 10
10 L20-386 R1 In the event of problems with or questions About your order, please contact the Anets Factory at: 1-603-225-6684 World Wide Website Address: www.anets.com MAILING ADDRESS – P.O. BOX 501, CONCORD, NH 03302-0501 SHIPPING ADDRESS – 10 FERRY ST., CONCORD, NH 03301 In the event of problems with or questions about your equipment, please contact the Anets Authorized Service and Parts representative (ASAP) covering your area, or contact...