Have a look at the manual Anetsberger Brothers 14Inch Gas Fryer MX14EX 14 high production User Manual CEUK online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 50 Anetsberger Brothers manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
TROUBLESHOOTING AND CONVERSION 8 L20 -351- UK Rev. 1 0 8/1 2 f. Reinstall the modified burner array assembly into the appliance. g. Reinstall the modified pilot assembly into the appliance. h. Apply the gas type conversion label, provided with the conversion kit, just below the data plate (located on the inside of the appliance door). i. Ensure that all steps of this procedure have been executed properly and that ALL gas connections are connected and retightened. j. Connect a manometer to the pressure test point on the burner manifold. k. Turn the gas supply to the appliance on and star t the appliance using the Appliance Start Up procedure in this manual. l. Using leak detector fluid, check ALL gas connections and orifice tips for leakage. If gas leakage is detected shut the appliance down using the Appliance Shut Down procedure in this manual, turn off the gas supply to the appliance and repair the leak. When the leak has been repaired repeat step ‘k’ in this procedure and continue through the procedure. m. With the main burners on, ensure that the burner pressure is correct for the gas type to which you have converted the appliance. Adjust the burner pressure, if necessary, by removing the cap screw on the gas valve regulator and turning the adjustment screw clockwise to increase burner pressure, counter -clockwise to decrease burner pressure. Replace regulator cap screw when finished. Gas Conversion Information and Specifications Model Fuel Type Gas Appliance Category Burner Pressure (mbar) Burner Orifice Pilot Orifice Code Governor MX14 NAT G20 I2H 9.0 1.15 mm N22 Yes NAT G25 I2L 10.0 #56 N22 Yes LP G31 I3P 25.4 0.70 mm LP16 Yes 14GS NAT G20 I2H 10.0 1.15 mm N22 Yes NAT G25 I2L 10.0 #56 N22 Yes LP G31 I3P 25.4 0.70 mm LP16 Yes
MAILING ADDRESS – P.O. BOX 501, CONCORD, NH 03302-0501 USA SHIPPING ADDRESS – 10 FERRY ST., CONCORD, NH 03301 USA In the event of problems with or questions about your equipment, please contact the Anets Authorized Service and Parts representative (ASAP) covering your area, or contact Anets at the number listed to the left. In the event of problems with or questions about your order, please contact the Anets factory at: (603) -225 -6684