    Have a look at the manual Anetsberger Brothers 14Inch Gas Fryer 14GS 14 standard User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 50 Anetsberger Brothers manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							FRYER OPERATlNG lNSRUCTlONS 
     
     
     
     
     
     
     
     
     
     
    B.  Schedule regular cleaning of the fryer to 
    ensure long-term satisfactory operation. 
    Refer to the Daily Cleaning Procedure, later 
    in this manual. 
    C.  Before servicing and maintenance, allow the 
    fryer to cool.  ALWAYS shut off the gas to 
    the fryer while working on it, to prevent 
    burns. 
    D.  Contact the factory 1-603-225-6684 for war- 
    ranty service authorization.  [Always notify 
    the factory the next business day about 
    ‘after-hours’ warranty service.] Contact 
    your local restaurant equipment service 
    agency for other service, repairs, or mainte-
    nance activities, as necessary. 
    E.  When breaded food products are being 
    cooked, 
    ANETS  recommends using the 
    special  (optional) sediment tray tocapture 
    any breading fragments that become loosened 
    from the food product.  Periodic clearing of 
    the sediment tray reduces premature 
    contamination of the liquid shortening from 
    breading fragments. 
     
     
     
     
     
     
     
     
    11
    ! 
    Avoid moving the fryer while it contains 
    HOT shortening.  Drain the shortening from 
    the fryer before moving it for service, clean-
    ing or maintenance to avoid spilling or 
    splashing.  Burns from hot shortening can 
    cause serious injury or death. 
    A. An ANETS Fryer is designed for opera-
    tion with a kettle filled with approximately 35
    to 50 pounds (or 3½ to 6 gallons) of liquid 
    shortening. 
    ! 
    CAUTION: DO NOT melt solid 
    shortening in this fryer because 
    the melting can damage the kettle, 
    which will void the fryer warranty.
    DANGER 
    ! CAUTlON 
    DO NOT attempt to operate this fryer during a interruption of gas service. 
    Turn all fryer controls to OFF, including the gas control valve knob, then 
    close the gas supply line valve.  When notified that the gas interruption 
    has ended, perform the Lighting Procedure (later in this manual). 
    ! DANGER 
    NEVER operate this fryer when its flue is blocked or when the 
    ventilation hood is not on because the combustion products 
    can cause injury to personnel. 
    Solid shortening must be melted into the liqui
    d
    state before it can be used in an ANETS 
    Fryer.  
    						
    							FRYER OPERATlNG 
    FRYER PREPARATION FOR USE 
    “BOIL OUT” INSTRUCTIONS 
    New ANETS Fryers are leak-tested and cleaned 
    at the factory before shipping.  Before using a 
    newly installed fryer for food preparation, clean the 
    kettle again, as follows: 
    1.  Thoroughly wipe the interior of the kettle 
    with clean cloths.  Open the front door on 
    the lower portion of the fryer to access the 
    drain ball valve. Open the drain ball valve 
    (by aligning the valve handle with the drain 
    ball valve) and wipe the entire drain line clean. 
    2.  Close the drain ball valve (turn the valve han-
    dle cross-wise to the drain ball valve). 
    Fill 
    the kettle with water to about 3“ from the 
    top.  Add 1 to 2 cups of soap powder, 
    washing soda (trisodium phosphate), or
     
    deep fat fryer kettle cleaner. 
    3. Perform the Lighting Procedure for the 
    fryer.  (Refer to the Lighting Procedure 
    later in this manual.) 
    4.  Set the thermostat to 190°F.  Heat, but DO 
    NOT boil the water.  Stir the water to dis-
    solve the cleaning material. 
     
     
     
     
     
     
     
    5.  Clean the fryer kettle for at least 20 minutes. 
    Use a small hand mop (an optional brush can 
    be ordered for this purpose) to clean the 
    upper portion of the kettle (above the 3
    “ 
    waterline) and the top rim of the kettle. 
    6.  Shut down the fryer using the Shutdown 
    Procedure for the fryer.  (Refer to the 
    Shut-
    down Procedure later in this manual.) Allow 
    the water to cool slightly. 
     
     
     
     
     
     
    12
    lNSTRUCTlONS (Continued) 
    FRYER PREPARATION FOR USE
    (Continued)
    CAUTION 
    For fryers with built-in filter systems, DO NOT 
    pump the cleaning, or rinsing, solution through 
    the filter system, to avoid damaging the filter 
    system pump. 
    7.  Open the front door and mount the drain 
    extension to the drain ball valve.  Position a 
    container (bucket) capable of  holding VERY 
    HOT cleaning solution beneath the end of the 
    drain extension to hold the cleaning solution 
    being drained, as shown in Figure 5. 
     
     
     
     
     
     
     
     
     
     
     
     
    Figure 5.  Draining The Kettle
    8.  Open the drain ball valve SLOWLY, to avoid 
    splashes while draining the cleaning solution 
    from the kettle. 
    9
    .  Close the drain ball valve (valve handle 
    crosswise) and remove the drain extension. 
    Close the front door. 
    10.  Safely dispose of the cleaning solution. 
    11.  Fill the kettle with water to about 3
    “ from 
    the top.  Add 2 cups of vinegar to neutralize 
    the cleaning solution. 
    12.  Repeat steps 3 through 10 of this procedure. 
    13.  Thoroughly wipe the interior of the kettle and 
    the drain ball valve with clean, dry, wiping 
    cloths to remove ALL water. 
    14.  Dry the kettle thoroughly because any re-
    maining water can cause sputtering of  hot 
    shortening when the kettle is later filled and 
    heated. 
    !
    !WARNlNG 
    Hot cleaning solution can cause severe 
    burns.  Take care when handling hot clean-
    ing solution to avoid spilling or splashing the 
    solution.  
    						
    							FRYER OPERATlNG lNSTRUCTlONS (Continued) 
    Normal operation of an 
    ANETS  Fryer requires that the kettle is filled with liquid shortening above the 
    lower indent level, marked on the rear of the kettle, before lighting the fryer’s pilot and turning on the main 
    burner. 
    CAUTION: Shortening MUST be in liquid form to avoid scorching or discoloration and possible 
    damage to the kettle.  Damage caused by melting solid shortening will NOT be covered by the warranty. 
     
    LIGHTING PROCEDURE 
    NOTE: The gas line of a new fryer installation 
    may contain a considerable amount of air that will 
    hinder immediate lighting.  You may have to press 
    in the gas safety valve control knob as long as 
    several minutes before the pilot flame burns 
    steadily. 
    1. Ensure that the fryer’s thermostat knob is set 
    to OFF. 
    2.  Open the gas supply line inlet valve to the 
    fryer by aligning the gas valve handle with the 
    gas line piping. 
    3.  Open the front door and move the right pilot 
    viewing/lighting port cover aside. 
    4.  Turn the gas control valve knob to align the 
    PILOT setting with the valve mark.  Figure 6 
    shows the possible gas control valve knob 
    positions.
     
    5
    . Press, and hold down, the valve control 
    knob to allow pilot gas to flow. 
    Model 14G, 14GU, 14GS, or 14GSU: Use 
    a match or lighter to ignite the pilot burner. 
    Model MX-14EG or MX-14EGU: Push 
    the spark igniter pushbutton several times, 
    until the pilot flame lights.  (A match may also 
    be used to light the pilot flame.) 
    Continue holding down the control knob for 
    at least 30 seconds until the pilot flame 
    burns steadily without going out. 
    6.  Release the control valve knob and observe 
    that the pilot flame remains lighted.  Close the 
    right pilot viewing/lighting  port.
     
    7
    .  Light the left pilot flame by opening the left 
    pilot viewing/lighting port and applying a 
    match to ignite the pilot flame. Close the 
    left pilot viewing/lighting port.
    ! 
    !CAUTION:  Ensure that both pilot 
    viewing/lighting ports are closed, to
    prevent excessive heat from damaging
    the gas controls. 
    8. Turn the gas control valve knob to align the
    ON setting with the valve mark. 
     
    9.  Turn the thermostat knob to the desired 
    temperature.  Observe that the fryer’s main
    burners light to heat the kettle. 
    European Valve
    Markings 
    OFF 
    PILOT 
    ON 
    Figure 6.  Gas Control Valve & Knob Positions 
    13
    Valve Mark
    ON
     
    OFF 
    OFF
     
    PILOT ON  
    						
    							FRYER OPERATlNG lNSTRUCTlONS (Continued) 
    SHUTDOWN PROCEDURE 
     
    NOTE: Shutdown is recommended at the end of 
    a workday or whenever no frying is required for a 
    period of several hours.  The fryer should be 
    shutdown during any power outage or interruption 
    of gas service.  The fryer MUST also be shutdown 
    before draining the kettle, or whenever there is no 
    shortening in the kettle to prevent damage. 
     
    1.  Turn the thermostat knob to OFF. 
    2.  Turn the gas control valve knob to align the 
    PILOT setting with the valve mark. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    143
    .  Open the pilot viewing/lighting  port to con-
    firm that only the pilot flame remains lighted.
    4. Press down and turn the gas control valve 
    knob to align the OFF setting with the valve 
    mark.  Observe that the pilot flame goes out.
    NOTE: For extended periods of non-use 
    or when servicing the fryer, close the gas 
    supply line inlet valve to the fryer by turning 
    the gas valve handle cross-wise with the gas 
    linepiping. 
    						
    							FRYER OPERATlNG lNSTRUCTlONS (Continued) 
    RECOMMENDED FRYlNG TlME FOR 
    POPULAR FRlED FOODS 
    Load the fryer basket with the 
    food product while the basket is 
    not in the hot liquid shortening. 
    DO NOT overload the fryer 
    basket. Load only a premeasured 
    quantity of food product (1½ lb, 
    typically; less, if smaller portions 
    are desired).  Place the loaded 
    fryer basket into the hot liquid 
    shorteningcarefully to avoid 
    splashing. 
    When the basket of food product 
    has reached the desired point of 
    ‘doneness’, lift the basket from 
    the hot shortening and hang the 
    basket on the basket hanger to 
    let it drain for approximately 15 -
    30 seconds before serving. 
    NEVER increase the thermostat 
    setting above the recommended 
    setting to reduce the cooking 
    time; this will produce a lower 
    quality product and will cause 
    more rapid shortening break-
    down. 
     
     
     
     
     
     
     
     
     
     
     
    * - Usual per order = Wing, Leg, Breast, Thigh (1/2 chicken) 
    **  - Use a second basket on top of the chips in the bottom basket, 
    to keep them within the hot shortening; otherwise, they float 
    before cooking completely. 
     
     
     
     
    15
    Food Product 
    (Typical 1½ lb load) 
    ANETS
    Fryer 
    (° F) Frying 
    Time 
    (minutes) 
    Breaded Foods 
    Calamari 
    Cheese Sticks 
    Fresh Shrimp (Breaded) 
    Frozen Shrimp (Breaded) 
    Mushrooms 
    Onion Rings 
    Tamale Sticks 
    Chicken 
    Croquettes (Nuggets) 
    Pre-cooked, Breaded Pieces 
    Raw to Done, Pieces* 
    Tenders 
    Corn Dogs 
    French Fries 
    Raw to Done  1/4” cut 
    Blanched, only  1/4” cut 
    Browned, only  1/4” cut 
    Raw to Done  3/8” cut 
    Blanched, only  3/8” cut 
    Browned, only  3/8” cut 
    Raw to Done  1/2” cut 
    Blanched, only  1/2” cut 
    Browned, only  1/2” cut 
    Fritters 
    Frozen Fish 
    Tortilla Chips**  
    340 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    340  
    2½ - 3 
    3 
    3 
    4 
    2½ - 3 
    2½ - 3 
    3 
     
    3 -  4 
    3 - 4 
    12 - 15 
    5 
    3½ 
     
    5 
    2½ 
    2½ 
     
    6 
    3 
    3 
     
    7 
    4 
    3 
    3 
    4 - 7 
    2 - 2½  
    						
    							FRYER OPERATlNG lNSTRUCTlONS (Continued) 
    DAILY CLEANING PROCEDURE  DAILY CLEANING PROCEDURE 
    (Continued) 
    Allow the shortening to cool before draining. 
    Slowly open the drain ball valve to drain the 
    shortening. Take care to avoid spilling or 
    splashing the shortening. 
    Carefully use the Cleanout Rod to clear any 
    sediment blocking the kettle drain.  Flush out 
    all sediment in the bottom of the kettle by 
    pouring filtered, liquid shortening into the ket-
    tle until the shortening being drained runs 
    clear. 
    Close the drain ball valve, after the kettle is 
    completely empty of shortening and sedi-
    ment.  Detach the drain extension.  Clean, 
    rinse, and dry it before storing. 
     
    WARNlNG 
     
     
     
    1.  Open the front door of the fryer.  Attach the 
    drain extension to the drain ball valve.
     
    2. Perform the Shutdown Procedure. Ensure 
    that the gas supply line inlet valve is closed 
    (handle cross-wise to pipe line) and the pilot 
    flame is extinguished. 
    3.  Position a steel drum [NEVER use plastic!] 
    with a filter cone, directly beneath the drain 
    extension end, OR if your fryer is equipped 
    with an ANETS Filtronic II or Filter 
    Mate unit, refer to that equipment’s manual 
    for operation details.
     
    4
    .  Remove the fryer baskets and the sediment 
    tray, if present, from the kettle.  (If the screen 
    is present, use the cleanout rod to lift it from 
    the hot shortening, to avoid burns.)  Thor-
    oughly clean, and rinse, these items in the 
    sink.  MAKE SURE that these items are 
    completely dry before their next use. 
     
     
    16
    NOTE: Cleaning is recommended at the end of a  5.
    workday, to prepare the fryer for proper operation 
    the next time it is to be used. 
     
    6.
     
     
     
     
     
    7.
     
    When cleaning, if relocation of your fryer is 
    necessary, disconnect the gas supply line to the 
    fryer.  Also, if your fryer is caster-equipped, unlock 
    the locking casters and disconnect the movement-
    limiting cable.  Move the fryer as necessary to 
    allow the following cleaning procedure to occur: 
    !DANGER 
    DO NOT move the fryer while it contains 
    HOT shortening.  Allow it to cool and 
    drain the shortening from the fryer be-
    fore moving it for service, cleaning, or 
    maintenance to avoid spilling or splash-
    ing.  [Refer to steps 1 through 7.] Burns 
    from HOT shortening can cause seri- 
    ous injury or death. 
    Wait until the kettle has cooled 
    before performing step 8, to avoid 
    injury from burns. 
     
    Thoroughly wipe the kettle interior using 
    clean cloths. 
    Periodically perform the “BOIL OUT” 
    Instructions to ensure thorough cleaning of 
    the kettle.  ( Refer to the earlier FRYER 
    PREPARATION FOR USE section.) 
    Return the fryer to its normal operating loca-
    tion and reconnect both the gas supply line 
    and the movement-limiting cable.  (For 
    caster-equipped fryers, lock the locking cas-
    ters to prevent movement.) 
    Refill the kettle with filtered (or fresh) liquid 
    shortening to the desired indent mark on the 
    rear wall of the kettle, only if fryer operation 
    is to continue during a subsequent shift. 
    Otherwise, melt shortening into its liquid state
    and refill the kettle before fryer operation is 
    sc
    heduledduringthenext working shift.
    !
    8.
     
    9.
     
     
     
    10.
     
     
     
     
    11.
    ™  
    						
    							FRYER OPERATlNG lNSTRUCTlONS (Continued) 
    DAILY CLEANING PROCEDURE 
    (Continued) 
    12.  Return the screen (or, if used, the sediment 
    tray) to its proper position in the kettle. 
    Place the fryer baskets on the basket hanger, 
    ready for use. 
    13. Perform the Lighting Procedure to return 
    the fryer to operation, when desired. 
     
     
    MONTHLY MAINTENANCE INSTRUCTIONS 
    NOTE: Regular maintenance is recommended to 
    keep the fryer operating properly. 
     
    Once each month, before beginning fryer opera-
    tion, check the flue (behind the backsplash panel) 
    to ensure that it is clear, enabling exhaust combus-
    tion gases to flow freely toward the ventilation 
    hood area.  DO NOT allow the flue to become 
    excessively dirty.  NEVER allow the flue to be 
    blocked.Monthly, observe the condition of the ventilation 
    hood.  If it shows evidence of a great deal of 
    greasy residue, remove (clean) the residue to allow 
    free flow of ventilation air. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    17 
    						
    							FRYER TROUBLESHOOTlNG GUlDE 
    All service (repairs or part replacement) must be performed by a qualified Service Agency. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    18
    PROBLEM CAUSE REMEDY 
    Pilot (piezo-electric) 
    pushbutton igniter, if 
    present, does not light 
    the pilot flame 1.  Electrode of igniter out of position or 
    dirty/sooty electrode. 
     
    2.  Loose spark wire; loose igniter nut. 
     
     
    3.  Piezo-electric igniter does not generate a 
    spark. 
    1. Move electrode within 3/16” of 
    pilot burner tip.  Clean the 
    electrode. 
    2.  Check spark wire connection at 
    the igniter nut and make sure 
    the connection is tight. 
    3. Replace igniter mechanism 
    (portion with pushbutton). 
    Pilot flame does not 
    stay lighted. 1. Dirty/sooty pilot burner. 
     
    2. Low gas supply pressure [less than 6” 
    W. C. for natural gas; (11” W. C .  for pro- 
    pane) when all other gas-powered equip-
    ment is operating]. 
     
    3.  Pilot flame too small to heat the thermo-
    couple. 
     
     
     
     
     
     
     
    4.  Pilot flame ‘wavering’ (being blown about 
    by a draft). 
    5.  Improper thermocouple output voltage 
    (must be at least 10 millivolts, measured at 
    the thermocouple junction block). 
    6.  High-limit thermostat problem has shut off 
    the gas. 
    1. Clean the pilot burner. Perform 
    the Lighting Procedure. 
    2.  Measure the gas supply pres-
    sure. 
    Contact your local gas supplier 
    to obtain adequate gas supply 
    pressure. 
    3.  Adjust the pilot valve (part of 
    the gas control valve) to in-
    crease the flame size:  Un-
    screw and retain the slotted 
    threaded cover; turn the pilot 
    valve adjustment screw 
    two 
    turns counterclockwise; 
    reinstall the threaded cover. 
    4.  Block or redirect the draft, to 
    keep the flame burning steadily.
    5.  Replace the thermocouple. 
     
     
    6.  Check for, and repair, any dam-
    aged high-limit thermostat wir-
    ing. [For model 14GSU fryer 
    ONLY: Press the reset push-
    button on the high-limit thermo-
    stat control.  Perform the Light-
    ing Procedure, to check wheth-
    er the pilot flame lights.  If the 
    pilot flame stays lit, the high-
    limit thermostat has failed and 
    must be replaced. 
    ]  
    						
    							FRYER TROUBLESHOOTlNG GUlDE (Continued) 
    REMEDY 
    6. (Continued) 
    For model 14GS, MX-14EG, 
    and MX14-EGU fryers ONLY: 
    Test the high-limit thermostat 
    by disconnecting the thermo-
    couple at the gas control valve. 
    Then, disconnect the red wires 
    to the high-limit thermostat 
    from the gas control valve. 
    Reconnect the thermocouple; 
    next, perform the Lighting Pro-
    cedure, to check whether the 
    pilot flame lights.  If the pilot 
    flame stays lit, the high-limit 
    thermostat has failed and must 
    be replaced. 
    CAUTION: DO NOT return 
    the fryer to normal operation 
    with its high-limit thermostat 
    bypassed/disconnected. 
     
    7.  Replace the gas control valve. 
     
    1. Measure the gas supply pres-
    sure. 
    Contact your local gas supplier 
    to obtain adequate gas supply 
    pressure. 
    2.  Check and tighten the connec-
    tions. 
    3. Block the excessive air flow to 
    make the pilot flame contact 
    the thermocouple. 
    4.  Check for, and repair, any dam-
    aged high-limit thermostat wir-
    ing.  [For model 14GSU fryer 
    ONLY: Press the reset push-
    button on the high-limit thermo-
    stat control.  Perform the Light-
    ing Procedure, to check wheth-
    er the pilot flame lights.  If the 
    pilot flame stays lit, the high-
    limit thermostat has failed and 
    must be replaced. 
    ] 
     
     
    19
    PROBLEM 
    Pilot flame does not 
    stay lighted. 
    (Continued) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    Pilot flame goes out 
    repeatedly. 
    CAUSE 
    6.  High-limit thermostat problem has shut off 
    the gas. (Continued) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    !
     
     
    7.  Gas control valve has failed. 
    1.  Low gas supply pressure [less than 6
    ” 
    W. C
    . for natural gas; (11” W. C .  for pro-
    pane) when all other gas-powered kitchen 
    equipment is operating]. 
     
    2.  Loose thermocouple or high-limit thermo-
    stat connection(s) on gas control valve. 
    3.  Pilot flame does not continuously touch 
    the thermocouple because of excessive 
    air flow around the pilot burner assembly. 
    4.  High-limit thermostat problem has shut off 
    the gas.  
    						
    							FRYER TROUBLESHOOTlNG GUlDE (Continued) 
    REMEDY 
    4. (Continued) 
    For model 14GS, MX-14EG, 
    and MX14-EGU fryers ONLY: 
    Test the high-limit thermo- 
    stat by disconnecting the ther-
    mocouple at the gas control 
    valve. Then, disconnect the red 
    wires to the high-limit thermo-
    stat from the gas control valve. 
    Reconnect the thermocouple; 
    next, perform the Lighting Pro-
    cedure,  to check whether the 
    pilot flame lights.  If the pilot 
    flame stays lit, the high-limit 
    thermostat has failed and must 
    be replaced. 
    CAUTION:  DO NOT return 
    the fryer to normal operation 
    with its high-limit thermostat 
    bypassed/disconnected. 
     
    1. Perform the normal Lighting 
    Procedure. Turn the gas 
    control valveknob to ON to 
    light the main burners. 
    If the burners do not light, the 
    gas control valve has failed and 
    must be replaced. 
    2. Measure the gas supply pres-
    sure. 
    Contact your local gas supplier 
    to obtain adequate gas supply 
    pressure. 
    3.  Refer to the preceding Pilot 
    Burner problems and use the 
    correct remedy. 
    4. Increase the thermostat setting 
    until the burners light.  If this 
    setting is greater than the de-
    sired temperature, reset the 
    thermostat to the desired set-
    ting and allow the shortening to 
    cool to the desired tempera-
    ture. 
    5.  Replace the gas control valve.
    CAUSE 
    4.  High-limit thermostat problem has shut off 
    the gas. 
    (Continued) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    !
     
     
    1.  Gas control valve knob set to OFF or 
    PILOT. 
     
     
     
     
     
    2.  Low gas supply pressure [less than 6” 
    W. C
    . for natural gas; (11” W. C .  for pro-
    pane) when all other gas-powered kitchen 
    equipment is operating]. 
     
    3. Pilot burner problem. 
     
     
    4.  Thermostat control set below the tem-
    perature of the liquid shortening in the 
    kettle. 
     
     
     
     
     
    5. Gas control valve has failed. 
    PROBLEM 
    Pilot flame goes out 
    repeatedly. 
    (Continued) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    Main burners do not 
    ignite. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    20  
    						
    All Anetsberger Brothers manuals Comments (0)