Page 1

January 2013 L010067
MBL600
Bilevel Step Motor Driver
User’s Guide
910 East Orangefair Lane, Anaheim, CA 92801
e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION 

Page 2

January 2013 L010067
General Description
The ANAHEIM AUTOMATION MBL600 is an improved version of the MBL628-B series step motor drivers.  
The MBL600 with it compactness and attractive rugged package style employs bilevel (or dual voltage) 
drive technique for high performance operation of step motors providing signifi cantly improved motor speed 
torque output.  New features include selectable “+” or “-” going clock inputs,  transient voltage protection, 
and improved Full-step operation.
Bilevel Drive...

Page 3

January 2013 L010067
Motor ON/OFF Option
The Motor ON/OFF option allows de-energizing a motor without disturbing the positioning logic.  After 
reenergizing the motor, a routine can continue.  This reduces  motor heating and conserves power,  es-
pecially in applications where motors are stopped for long periods and no holding torque is required.
Motor Connections
Hookup diagrams for a motor driver application are presented in Figure 3 and 4.  Wiring connected to input 
must be separated from motor...

Page 4

January 2013 L010067
Jumper Functions/Locations
Function JP1 JP2
Terminal 5 = Direction 2 - 3 X
Terminal 5 = CCW 1 - 2 X
Positive Going Clocks X 2 - 3
Negative Going Clocks X 1 - 2
Standard Product 2 - 3 2 - 3
Torque Speed Curves
Torque curves are shown on the back of this specifi cation sheet.  This data was obtained using a high 
voltage (Vhv) of approximately 60VDC no load.  The low voltage (Vlv) used was an unregulated voltage 
of about 5VDC no load.  Both voltages dropped when loaded.
To obtain more...

Page 5

January 2013 L010067
Wiring Diagrams 

Page 6

January 2013 L010067
Specifi cations
Control Inputs:
TTL-Compatible
Logic “0” - 0 to 0.8V
Logic “1” - 3.5 to 5.0V
Clock Inputs: (Terminals 5 & 6)
Pulse Required; 15 microseconds minimum.  The clock input is pulled up internally to +5VDC through a 
10K Ù resistor for negative going clock inputs or pulled down to 0VDC through a 10K Ù resistor for posi-
tive going clock inputs. 
Direction Control: (Terminal 5)
Logic “1” (open) - Clockwise
Logic “0” - Counterclockwise
Excitation Mode Select: (Terminal 8)...

Page 7

January 2013 L010067
ANAHEIM AUTOMATION
COPYRIGHT 
Copyright 2013 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, 
transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by 
any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior 
written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. 
DISCLAIMER
Though every effort has been made to...
Start reading Anaheim Stepper MBL600 Users Guide