    8 Lead Motors
    Series Connection: When confi guring the motor windings in series, use the per phase (or uni-
    polar) current rating to determine the current setting potentiometer value.
    Parallel Connection: When confi guring the motor windings in parallel, multiply the per phase (or 
    unipolar) current rating by 2.0 to determine the current setting potentiometer value.
    Note: After the current has been determined, according to the motor connections above, use 
    the potentiometer setting table to choose the proper setting for the current setting potentiometer.
    Connecting the Step Motor
    The MBC25SI1TB is designed to accept one motor.  For wiring of the motor refer to the pages 
    containing the connector descriptions and hookups diagrams.
    Note: The physical direction of the motor with respect to the direction input will depend on the 
    connection of the motor windings.  To reverse the direction of the motor with respect to the direc-
    tion input, switch the wires on phase 1 and phase 3. 
    WARNING: Do not connect or disconnect motor wires while power is applied!
    Circuit Protection
    This driver is equipped with over current protection.
    Note: When drive experiences a fault condition, it will seize to function.  Power down, inspect 
    wiring, motors, etc. and allow for a 30 second pause to resume functioning.  If driver is too hot, 
    additional ventilation and airfl ow should be added to prevent temperature to exceed recommended 
    temperature limit. 
    						
    							August 2012 L01044012
    Functions
    Hard Limit Switches: When a hard limit switch is encountered, the pulses will stop.  Hard limits 
    are intended as an emergency stop for your system.
    Soft Limit Switches: These switches cause the indexer to ramp down to the base speed and 
    fi nish the index, unless encountering a hard limit switch.
    Profi le Inputs: These inputs are used to select and begin the specifi ed motion profi le.  Only 1 
    input should be activated at a time.
    Motion Profi les: The indexer will accept two different speed or motion profi les.  Each profi le has 
    its own programmable Accel/Decel, Base speed and distance value.  These values are stored in 
    EEProm for standalone use and must be programmed before the pulse generator is ran.
    Acceleration/Deceleration: The acceleration and deceleration are by default the same value.  
    This function controls the time that the motor will take to move from base speed to max speed.  
    The higher the value, the slower the motor will accelerate.  The same principle applies for the 
    deceleration which is controlling the time it takes to go from maximum speed to base speed.  
    The higher the value, the slower the pulses will decelerate.  The different accel/decel profi les are 
    stored in EEprom for standalone use.  (Range: 100 to 9,999,999)
    Base Speed: The base speed is the speed at which motion starts and stops.  It is entered directly 
    as the number of steps per second.  This speed must always be less than the max speed.  The 
    different base profi les are stored in EEprom for standalone use.  (Range:1 to 5000)
    Max Speed: The max speed is the top speed the user wants the pulses to run at.  This speed must 
    always be equal or greater than the base speed.  It is entered directly as the number of steps/
    second.  The different max profi les are stored in EEprom for standalone use. (Range:1 to 50,000)
    Index Number: The index number is the number of steps that the motor will take when the motion 
    profi le starts.  It is entered directly as the number of steps to take.  The different index profi les 
    are stored in EEprom for standalone use. (Range: 0 to 8,388,607)
    Direction Input: If this input is open then the unit will be running in the clockwise direction.  If 
    this input is active then the unit will be running in the counterclockwise direction.  This pin can 
    be overridden by the programmable software direction.  It will activate the direction output when 
    the pin is changed.  This means, that if you start the profi le from the software, the unit will look 
    at the software direction.  If you start the indexer from the inputs, then the unit will look at the 
    direction input.
    Busy Input: This output will be pulled low when the indexer is operating.  It is an open drain 
    output so when the indexer is not running the pin is open.
    Clock Output: The external clock is the output of the internal pulse that can be used to daisy 
    chain other step motor drivers together.  This is an open collector output that is capable of sink-
    ing 10mA. 
    						
    							August 2012 L01044013
    SMPG-SMSI Software
    The SMPG-SMSI software is a handy utility that supports Anaheim Automation’s programmable 
    pulse generators and simple indexers.  Connecting your PC to the MBC25SI1TB, via a serial 
    cable, the software can easily perform the following tasks:
    •  Exercise and monitor the MBC25SI1TB
    •  Directly communicate with the MBC25SI1TB
    Installation
    Software
    •  The SMPG-SMSI software is supplied on a CD, containing the setup program and the 
    software.
    •  SMPG-SMSI software is compatible with all versions of Windows including Windows 
    2000, Windows XP, Vista, and Windows 7
    Windows 3.x Installation
    1.  Insert the CD into the drive
    2.  From the Program Manage select File │ Run
    3. Enter D:\setup and click OK - use the appropriate drive letter (i.e. D or E)
    Windows 95/98/NT/ME/2000/XP Installation
      Option 1
    1.  Insert the CD into the drive
    2.  From the Program Manager select Start │ Run
    3. Enter D:\setup and click OK - use the appropriate drive letter (i.e. D or E)
      Option 2
    1.  Open Windows Explorer
    2.  Open CD Drive Folder (D: or E:)
    3.  Double Click the setup Icon
    Getting Started
    1.  Double click on the SMPG-SMSI icon to run the software.
    2.  Apply power to the MBC25SI1TB unit.
    3.  Set the appropriate communication setting by selecting Setup │ Communication Set-
    ting from the menu bar.
    4.  Establish communications with the MBC25SI1TB by clicking on the Connect Icon, or 
    select Setup│Connect.  If the unit is connected properly, the program will notify you 
    when communication has been established and the correct programming tab will be 
    enabled to let you work with the unit.
      
    						
    							August 2012 L01044014
    File Menu
    Setup Menu
    Toolbar
    Exit Exit the SMPG10WIN Software
    Connect Establish communications with the controller.
    Disconnect Discontinue communications and release the comport for use by other devices.
    Communication Settings... COM port Selection (Ports 1, 2, 3, 4, 5, 6 or 7)
    Exit Exit the SMPG-SMSI Software
    Connect Establish communications with the controller.
    “The Unit is Connected” / “The Unit is Not Connected”
    On the right of the Toolbar, the user will fi nd the communication status of the pulse generator.  If 
    communications is not established, please refer to the troubleshooting section. 
    						
    							August 2012 L01044015
    Program Window
    Motion Profi le Select motion profi les 1, 2, 3 or 4.
    Send Accel/Decel Send the acceleration & deceleration parameter to the indexer. (steps/sec
    2)
    Send Base Spend Send the base speed parameter to the indexer. (steps/sec)
    Send Max Speed Send the maximum speed parameter to the indexer. (steps/sec)
    Send Index Number Send the index number parameter to the indexer. (steps)
    Begin MotionMotor will ramp up to maximum speed and keep moving until a limit switch is 
    triggered or the index is complete.
    Soft LimitMotor will ramp down to base speed and continue running until the index is 
    complete.
    Hard Limit Stop any motor motion.
    Direction Set direction to clockwise or counter-clockwise. 
    Reduced Current Set reduced current on or off.
    Microstep Resolution Set microstep resolution to divide by 1, 2, 4, or 8.
    Verify Parameters Updates and displays controllers parameters and resets the error codes. 
    						
    							August 2012 L01044016
    Direct Talk Mode
    Direct mode is used to directly control the motion for real time movements through serial com-
    munication.  The pulse generator has 14 commands which are easy to remember for direct 
    movement of a step motor.
    COM Port Settings
    Baud Rate: 38400
    Parity: None
    Data Bits: 8
    Stop Bits: 1
    Flow Control: Xon/Xoff
    Unit Selection
    In order to select a unit the @ command followed by 0 (address of the unit) must be sent.
    NOTE: There should be no spaces between the @ and the 0.
    How to select the unit:
    @0  (Unit is selected)
    How to get a response from the unit:
    @0$ (Carriage Return)
    After the $ command, the pulse generator will return a SMSI10 + the current version number
    Note: In direct talk mode each command is followed by a carriage return.
    The unit communicates in half duplex mode, therefore proper setup of hyper terminal is neces-
    sary to view characters, if characters are to be echoed back to the screen.
    Instructions
    All instructions require that no spaces be sent between the command and the parameter followed 
    by a carriage return.  The commands are also case sensitive and are all sent as capitals.
    Command Summary:
    A - Acceleration/Deceleration    R - Microstep Resolution
    B - Base Speed      S - Soft Limit
    C - Current Reduction     V - Verify
    G - Go (Index)      + - Clockwise Direction
    H - Hard Limit      - - Counterclockwise Direction
    M - Max Speed      $ - Version Number Register
    N - Index Number      ! - Error Codes Register   
      
    						
    							August 2012 L01044017
    $ - Version Number Register
    Format:   $
    Description:  This command request the pulse generator to return the version number.
    ! - Error Codes Register
    Format:   !
    Description:  This command requests the pulse generator to get the current error code 
    and print it to screen.
    +/- - Direction
    Format:   + or -
    Description:  This command sets the direction output.  A “+” sets the output to clockwise, 
    and a “-” set the output to counterclockwise.  This must be done when the indexer is not 
    busy.  This value is saved in the EEprom for standalone use.
    A - Acceleration/Deceleration
    Format:   A#_[value] - where # is the motion profi le number 1 thru 4
    Sample:   A1_10000  Accel of profi le 1 equals 10000
    Description:  This command sets the acceleration profi le which can be an integer value 
    between 100 and 9,999,999.  These values are saved in the EEProm for standalone use.
    Range:    100 - 9,999,999
    B - Base Speed
    Format:   B#_[value] - where # is the motion profi le number 1 thru 4
    Sample:   B3_500  Base Speed of profi le 3 equals 500
    Description:  This command sets the base (start) speed for motion.  This value must be 
    set before motion begins and be less then the maximum speed.  The pulses will ramp down 
    to this speed after a soft limit is triggered and run at this speed until a hard limit is triggered 
    or the index has fi nished.  These values are saved in the EEProm for standalone use.
    Range:    1 - 5000 
    						
    							August 2012 L01044018
    C - Current Reduce Option
    Format:   C# - where # is 0 or 1
    Description:  This command enables the driver to reduce current after pulses are done 
    being sent.  A 1 will enable current reduction, and a 0 will disable current reduction.  This 
    value is saved in the EEProm for standalone use.
    G - Go Slew (Run)
    Format:   G# - where # is the speed profi le number 1 thru 4
    Description:  This command will send clocks out to the pulse generator.  The only com-
    mand that can stop the clocks is H (stop motion).  The S (soft limit) command will make the 
    pulses go from max speed to base speed.  Motion can also be stopped by using the limit 
    switch inputs.  The ramp profi le is specifi ed by the B (base speed), M (max speed), and A 
    (acceleration/deceleration) commands.
    H - Hard Limit or Stop Motion
    Format:   H
    Description:  This command will stop all motion.  It can only be used when pulses are 
    running.
    M - Max Speed
    Format:   M#_[value] - where # is the motion profi le number 1 thru 4
    Sample:   M2_10000  Max Speed of profi le 2 equals 10000
    Description:  This command sets the maximum (running) speed for motion.  This value 
    must be set before motion begins and be equal or greater than the base speed.  The motor 
    will run at this speed until a soft limit or a hard limit is triggered.  These values are saved in 
    the EEProm for standalone use.
    Range:    1 - 50,000
    N - Index Number
    Format:   N#_[value] - where # is the motion profi le number 1 thru 4
    Sample:   N4_10000  Index number of profi le 4 equals 10000
    Description:  This command sets the number of pulses to index for the motion profi le.  
    This value must be set before motion begins.  These values are saved in the EEProm for 
    standalone use.
    Range:    0 - 8,388,607 
    						
    							August 2012 L01044019
    R - Microstepping Resolution
    Description:  This command enables the user to select the desired resolution for the mi-
    crostepping driver.  Divisions for the driver are Full step (1), Half step (2), Quarter step (4), 
    and Eighth step (8).  This value is saved in the EEProm for standalone use.
    Format:   R# - Where # is 1, 2, 4, or 8 - Soft Limit
    S - Stop Soft
    Format:   S
    Description:  This command will cause the indexer to ramp down to base speed and run 
    until the index is complete or a hard limit is activated.  It can only be used when pulses are 
    running.
    V - Verify
    Description:  This command can be used with most commands to verify the register con-
    tents.  This is a read only command.  Valid Commands are: A, B, C, D, M, R, and +.
    Format:   V[command]
          This format is good for C, D, R, and +.
        C  -    If a 1 is sent back then the driver is in reduced current mode.  If a 0 is sent  
          back then the driver is not in reduced current mode.
        D -   If a 1 is sent back then the pulse generator will ramp down to stop when the
           Run/Stop input is released.  If a 0 is sent back then the pulse generator will
          stop hard when the Run/Stop input is released.
        R -  If a 1 is sent back then the driver is in Full step mode. If a 2 is sent back then 
          the driver is in Half step mode.  If a 4 is sent back then the driver is in Quarter 
          step mode.  If an 8 is sent back then the driver is in Eighth step mode.
        + -   If a 1 is sent back then the direction is clockwise.  If a 0 is sent back then the
           direction is counterclockwise.
    Sample:   VD  Verifi cation of Direction is prompted.
    Format:   V[command]# - Where # is the speed profi le number 1 thru 4
          This format is good for A, B, and M.
        A# -   Verify Acceleration/Deceleration for given speed profi le.
        B# -   Verify Base Speed for given speed profi le.
        M# -  Verify Max speed for given speed profi le.
        N# -  Verify Index number for given speed profi le.
    Sample:   VB3  Verifi cation of Base Speed in Profi le 3 is prompted.
      
    						
    							August 2012 L01044020
    Troubleshooting
    Problem:
    Can not establish communications with the unit.
    Possible Solutions: 
    1.  Make sure the indexer has power.  Is the Green LED on.
    2.  Check RS232 connections.
    3.  Check for loose cable connection either on the pulse generator or COM Port.
    4.  Was the software installed successfully?
    5. Go to Setup│ Communication Settings and verify COM Port settings.
    6. Click on Connect icon to communicate with the unit.
    7.  If problems still exist, contact Anaheim Automation Tech Support.
    Problem:
    There is no power to the indexer.
    Possible Solutions:
    1.  Is the Indexer connected to the appropriate power supply?
    2.  Check for any blown fuses in line with the unit.
    3.  If problems still exist, contact Anaheim Automation at 714-992-6990.
    Problem:
    The indexer has a fault condition.
    Possible Solutions:
    1.  To Clear an error use either the SMPG-SMSI software or the direct mode command. 
    2.  The SMPG-SMSI software can clear an error in the motion tab section by clicking on 
    the Verify Parameters button.
    3.  The direct mode command “!” can clear an error by prompting indexer to serially send 
    the error code back to the user.
    Example: @0! (carriage return)
    Description: Address the unit by typing @ followed by a 0 (address number) an ! (Error 
    Codes Register) and a carriage return.
    Note: The error code is returned in binary coded decimal format.  If two errors were received 
    their binary values would be added together. 
    						