Anaheim Stepper DPX01E16 Users Guide
Here you can view all the pages of manual Anaheim Stepper DPX01E16 Users Guide. The Anaheim manuals for Stepper are available online for free. You can easily download all the documents as PDF.
Page 1
1 #L010147February 2004 DPX01E16 6 Axis Driver Pack User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION
Page 2
2 #L010147February 2004 Communications Baud Rates A term used frequently in serial data communications. A “baud” is defined as the reciprocal of the shortest pulse duration in a data word signal, including start, stop, and parity bits. This is often taken to mean the same as “bits per second”, a term that expresses only the number of “data” bits per second. Very often, the parity bit is included as an information or data bit. This unit accepts a baud rate of 115200 only and protocol settings of 1 start...
Page 3
3 #L010147February 2004 Electrical Specifications Power Requirements: 90-265 VAC Single Phase Operating Temperature: 0º to 60º C Pulse Output Range: 1 to 10,000 steps/sec Limit Inputs (TTL-CMOS): Logic “0”: 0 to 0.8VDC (1mA) Logic “1”: 3.5 to 5.0VDC (0mA) Inputs are internally pulled high Baud Rate: 115200 BAUDData Format: 1 start bit, 8 data bits, no parity, 1 stop bit Outputs (8 programmable): Open Drain Type 24V, 500mA Vce(sat) = 300mV @ 100mA, 50mV @ 400mA Note: For inductive loads a clamping diode...
Page 4
4 #L010147February 2004 Axis Selection Each controller will be addressed using a two position dip switch allowing the PC to address up to 4 controllers from one port. The switch is located on top of the unit. s i x A d e t c e l e S1 W S g n i t t e S2 W S g n i t t e S 0FF OFF O 1NOFF O 2FF ONO 3NONO Reducing Output Current Reducing the output current is accomplished automatically and occurs approximately 20mSec after a move is finished. The amount of current per phase in the reduction mode is...
Page 5
5 #L010147February 2004 COM Port Settings Baud Rate:115200 Data Bits:8 Parity:None Stop Bits:1 Flow Control:Xon/Xoff Unit Selection In order to select a unit the @ command followed by the address of the unit must be sent. NOTE: There should be no spaces between the @ and address select. How to select a unit: @0 (Unit 0 is selected) @1 (Unit 1 is selected) @3 (Unit 3 is selected) How to get a response from a unit: @0$ (Carriage Return) After the $ command, the controller will return an ESS06 + the current...
Page 6
6 #L010147February 2004 A - Acceleration/Deceleration Format: A#_ [value] ex:@0A1_10000 Description: This command sets the acceleration profile based on the following function Speed 2 = Accel/Speed 1 + Speed 1 Each axis has its own accel value and needs to be entered in separately for each one. This value must be set before motion begins. Range: 100 - 999,999 Default:1000 B - Base Speed Format: B#_ [value] ex:@0B4_100 Description: This command sets the base (start) speed for motion. This value must be...
Page 7
7 #L010147February 2004 G - Go Format: G# ex:@0G5 Description: This command tells the given axis to move the number of steps set in the index register for that axis. All speed profile information must be set for the given axis before this command is used. I -Index Distance Format: I#_[value] ex:@0I6_4000 Description: This command sets the number of steps for the motor to move following a G command. Each axis has its own index value and needs to be entered in separately for each one. This value must be...
Page 8
8 #L010147February 2004 + - Direction Clockwise Format: + ex:@0+ Description: This command sets the direction for all of the axes to clockwise. A value of 1 will be sent back to the PC after this command is received. This is the default value for direction - - Direction Counter-Clockwise Format: - ex:@0- Description: This command sets the direction for all of the axes to counterclockwise. A value of 0 will be sent back to the PC after this command is received. $ - Version Number Register Format : $...
Page 9
9 #L010147February 2004 Troubleshooting Problem: Can not establish communications with the controller. Possible Solutions: 1) Make sure the controller has power. 2) Check RS485 connections. 3) Check for loose cable connection either on the controller or COM Port. 4) Verify that the address is correct 9) If problems still exist, contact Anaheim Automation Tech Support... Problem: There is no power to the controller. Possible Solutions: 1) Is the driver pack connected to the appropriate power supply? 2)...
Page 10
10 #L010147February 2004 Appendix 1: Hyper Terminal Setup To use Hyper Terminal with the DPX01E16, proper setup is required. Follow the procedures listed below for proper communication. Most versions of the Windows operating system includes Hyper Terminal. 1) Open HYPERTRM.EXE on the PC 2) Choose a name and icon to identify the file. The file will have the .ht extension when saved 3) Then select the correct com port to communicate with in the Connect To tab 4) The next screen is the Configure command...