    							HIGH VOLTAGEYEL
    YEL
    REDLOW VOLTAGE
    0VDC RED
    ORG
    AC LOGIC VOLTAGE
    ORG 10VACPOWER SUPPLY KITS
    ANAHEIM AUTOMATION
    910 E. ORANGEFAIR LANE
    ANAHEIM, CA 92801
    (714) 992-6990   FAX (714) 992-0471
    www.anaheimautomation.com
    e-mail: [email protected]
    July 8, 2002
    #L010086The Bilevel Power Supply Kits in this booklet are designed to be used with Anaheim
    Automation Bilevel Step Motor Drivers.  These Power Supply Kits supply drivers with a
    High Voltage, a Low Voltage, and a logic voltage.  The following items should be
    included with the power supply kit:
    (1) Transformer
    (2) Filter Capacitors *
    (2) Capacitor Clamps
    (2) Diode Bridges
    Misc. Hardware
    *See figures for values.
    A typical hookup diagrams for the Power Supply Kits is shown above (specific hookup
    diagrams are shown on the inside pages).  The Yellow winding is the High Voltage
    Winding.  The Red winding is the Low voltage Winding, and the Orange winding is the
    Logic winding.  Notice that the High Voltage is stacked on top of the Low Voltage
    supply (the - terminal of the High Voltage diode bridge is connected to the + terminal
    of the Low Voltage diode bridge).  It is strongly recommended tostack the power
    supplies as shown in the diagrams.  
    Some transformers have two windings on the primary side; these transformers can be
    wired to operate on 115VAC nominal or 230VAC nominal.  The two windings should be
    wired in parallel for 115VAC operation.  For 230VAC operation, the two windings should
    be wired in series (see specific examples). 
    Some drivers such as the BLHP101 will also require an AC Logic voltage (orange pair
    winding); some drivers do not require the logic voltage (refer to the driver specifications). 
    If your driver does not require this logic voltage, a +5VDC power supply can be created
    from this winding to power up other circuitry (refer to figure 6).  If this winding is not
    used, insulate the ends of these wires with heat shrink tubing or electrical tape.
    The voltages for all power supply kits are shown in the hookup diagrams.  These
    voltages shown are the NO LOAD voltages; they will drop when the driver and motor are
    connected.
    Below is a list of power supply kits which are compatible with the drivers listed. 
    						
    							0.156 HOLE, 3 PLACES
    3 IN DIA, 120E APART1     IN.156 HOLE, 2 PLCS13
    162.5 IN DIA, 120E APART 0.156 HOLE, 3 PLACES10,000uF  75V8,200uF 160V
    58,000uF  16VDRIVERCOMPATIBLE POWER SUPPLY KITS
    MBL536PSK32791Ni
    MBL600PSK32791Ni
    BLHP101PSK42409Ni
    i STANDARD KITS
    DIMENSIONSA drawing of the transformer should be included with the power supply kit.  Dimensions
    of the capacitors are shown in the table below.
    CAPACITORDIAMETERLENGTH
    10,000uF  75V2.54.125
    58,000uF  16V1.3753.125
    8,200uF  160V2.05.125
    The mounting hole patterns for the capacitor clamps are shown below.
    FIGURE 1: Hookup Diagram for PSK32791N
         115VAC LINE VOLTAGE 
    						
    							figure2: Hookup Diagram for PSK32793N
    w/ 230VAC line voltage 
    figure3: Hookup Diagram for PSK32793N FIGURE 4: Hookup Diagram for PSK42409N
        w/ 230VAC LINE VOLTAGE
        115VAC LINE VOLTAGE 
    						
    							1.5A BRIDGE
    ORG
    ORG
    2200uF
    16VLM7805 IN
    GNDOUT10uF
    25V
    +5VDC
    0VDCFIGURE 6:  +5VDC @ 1 Amp Supply created      
                     from Orange Logic Windings. figure5: Hookup Diagram for PSK42409N
    115 VAC LINE VOLTAGE
    910 E.ORANGEFAIR LANE ANAHEIM, CA 92801
    (714) 992-6990   FAX: (714) 992-0471 
    						