December 2012 L010671 ACSD050-120051 Series AC Motor Controller User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION
December 2012 L010671 General Description The ACSD050-120051 is a Solid State AC Motor Control. It is designed for various mounting positions. It operates with 115 VAC, 50/60 Hz and is capable of 5.0 Amps RMS @ 50°C. With proper heatsinking, higher operating currents can be obtained. The ACSD050-120051 provides infi nitely variable speed motor control for Shaded Pole, Permanent Split Capacitor Motor, Capacitor Run Motor, and Universal Motors. The ACSD050-120051 variable speed motor control provides a basic form of speed control and a switch input for motor RUN/STOP. Applications include range hoods, vibrators, humidifi ers, fi replace blowers, fans, laminar fl ow hoods, heat tunnels and stirrers. ACSD050-120051 AC Motor Controller Features • 115 VAC 50/60Hz Input • Wide Range Speed Control • Compact Package • Easy to Use • Low Cost • Quick Disconnects for Easy Connections • Switch Input for RUN/STOP Applications • Effi cient and Durable •Long Life Expectancy Figure 1: Torque Speed Curve of a Induction Motor Varying line voltage.
December 2012 L010671 How it Works The ACSD050-120051 is a simple phase control driver which varies the effective RMS line voltage. The torque developed by an induction motor is proportional to the square of the applied voltage. If the load has a torque-speed characteristic such as shown in Figure 1, then the speed of the motor can be controlled over a small range by varying the line voltage. This curve is not to be confused with a universal type mo- tor curve, as a universal motor can be used with this driver as well. Otherwise, a different type of motor and control application needs to be visited. Input Pin Descriptions The ACSD050-120051 is a simple AC motor speed control. The speed is adjusted by the onboard po- tentiometer. Pin I1 and I2 needs to be connected together via Switch or a simple jumper if the feature is not being used. Input Pin C1 and C2 is the connection for a running/start Capacitor. Pin MC is where the common point of the Main and Auxiliary winding of a AC Induction or AC Reversible motor. Pin M1 and M2 is where the Main and Auxiliary windings connect to respectively. Switching Directions Switching Directions can be either be done by switches or by simply reversing the main and auxiliary windings from one pin to the other. Input Pin Descriptions Pin # Description L AC-HOT N PGND MC Motor Common M1 Main Winding M2 Auxiliary Winding C1 Capacitor Con. C2 Capacitor Con. I1 RUN/STOP I2 RUN/STOP Power Pin Descriptions Pin # Description L 120 VAC N0 VAC Item Min Typ Max Units Input Voltage (Power) 40 120 140 VAC Output Current - 5 A(RMS) Operation Temperature 0 80 C Table 1: ACSD050-120051 Input ConnectionsTable 2: ACSD050-120051 Power Connections Table 3: Electrical Specifi cations Absolute Maximum Ratings Input Voltage: 140 VAC Output Current: 5A RMS Max Plate Temperature: 80°C Storage Temperature: 0° to +50°C
December 2012 L010671 Dimensions Figure 2: Dimensions for ACSD050-120051 Hook-Up Drawings For other motor connections, such as a universal motor or other 2 wire connections, one can connect the leads to the MC and M1 quick disconnects. If doing so, please cover the M2, C1, C2, connections so shock or injury will not occur. Power Supply Recommendation The ACSD050-120051 must be powered by 120 VAC 50/60Hz. Warning: When using a higher current motor, the driver may overheat and burnup. Use additional airfl ow and heatsinking to keep motor and driver temperature under 80°C.
December 2012 L010671 ANAHEIM AUTOMATION COPYRIGHT Copyright 2012 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. DISCLAIMER Though every effort has been made to supply complete and accurate information in this manual, the contents are subject to change without notice or obligation to inform the buyer. In no event will Anaheim Automation be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation. Anaheim Automation’s general policy does not recommend the use of its’ products in life support applications wherein a failure or malfunction of the product may directly threaten life or injury. Per Anaheim Automation’s Terms and Conditions, the user of Anaheim Automation products in life support applications assumes all risks of such use and indemnifi es Anaheim Automation against all damages. LIMITED WARRANTY All Anaheim Automation products are warranted against defects in workmanship, materials and construction, when used under Normal Operating Conditions and when used in accordance with specifi cations. This warranty shall be in effect for a period of twelve months from the date of purchase or eighteen months from the date of manufacture, whichever comes fi rst. Warranty provisions may be voided if products are subjected to physical modifi cations, damage, abuse, or misuse. Anaheim Automation will repair or replace at its’ option, any product which has been found to be defective and is within the warranty period, provided that the item is shipped freight prepaid, with previous authorization (RMA#) to Anaheim Automation’s plant in Anaheim, California. TECHNICAL SUPPORT If you should require technical support or if you have problems using any of the equipment covered by this manual, please read the manual completely to see if it will answer the questions you have. If you need assistance beyond what this manual can provide, contact your Local Distributor where you purchased the unit, or contact the factory direct.