L298 INH1 PHAPHB LS7290 23 21 20 6 5 7 SLOW / FAST FIGURE 8. Selecting Between Fast and Slow Decay for One Steppe\ r Motor Winding (Use identical circuit for the other stepper motor winding ) NOTE: In fast decay mode, inhibit windings are chopped.\ In slow decay mode mode, phase windings are chopped NOR Gates: CD4001 OR Gates: CD4071 7290-061609-11
7290-061609-12 LS7290 21 (19 ) PHA PHB INH1 SENSE1 20 (18 ) 23 (22 ) 15 (14 ) V M = 120V 1N758 1N758 2N5551 2N55511k1k 10k 10k 10k 10k 1N4003 MOTOR WINDING 1N4003 Q1 Q2 Q4 Q3 Inverters = 74HC04 Gates = 74HC08 Q1 = Q3 = IRF6218 (Typical) Q2 = Q4 = IRF3615(Typical) FIGURE 9. 120V Motor Discrete Component Driver