Page 1
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com PKG-343-MLA-CBL System Diagram and Specifications L010886 Included Components: 34Y314S-LW8-MS Stepper Motor MLA10641 Stepper Driver CBL-18AWG-04C-010-MS Motor Cable PWR-10EMC1 Power Filter LIN-AA4254 Power Cord Sheet1 Page 1 0 60 120 180 240 300 360 420 480 540 600 0 150 300 450 600 750 900 1050 1200 1350 1500 0 5 10 15 20 25 30 35 40 45 50...
Page 2
FEATURES SPECIFICATIONS/DIMENSIONS 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com The 34Y314S-LW8-MS High Torque Stepper Motor offers a great value without sacrificing quality. This motor was designed to offer the highest possible torque while minimizing vibration and audible noise. It is wired in series with a Molex 4 pin Mini-Fit Jr. receptacle. A 10 ft. 4 conductor, 18 AWG cable with mating 4 pin Mini-Fit Jr plug is...
Page 3
FEATURES DESCRIPTION 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com The MLA10641 high-performance microstepping driver has an output current capability from 2.0 Amps minimum to 10.0 Amps maximum (peak rating). The MLA10641 driver operates with an AC voltage of 90-132 Volts. The inputs are optically isolated with a minimum sourcing of 7.0 mA per input (+5VDC minimum to +24VDC maximum). The clock input is set to receive...
Page 4
Pin #Description 1 Step Clock Input Anode (+): A positive going edge on this isolated input advances the motor by one increment. The size of the increment is dependent on the Microstep Select Inputs of the DIP switch. 2 Step Clock Input Cathode (-) 3 Direction Anode (+): This isolated input is used to change the direction of the motor. Physical direction also depends on the connection of the motor windings. 4 Direction Cathode (-) 5 ON/OFF Anode (+): This isolated input is used to enable and...
Page 5
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com Reducing Output Current Reducing the output current is accomplished by setting switch 1 of the DIP switch to the ON position. This should occur approximately 1 second after the last positive going edge of the step clock input. The amount of current per phase in the reduction mode is approximately 50% of the set current.The output current on the MLA10641 is set by...
Page 6
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com ResolutionSteps/Rev Position 1Position 2 Position 3Position 4Auto Reduce Current 1 200 OFF ONONON Disabled 2 400 OFF ONONOFF Disabled 5 1000 OFF ONOFF ON Disabled 8 1600 OFF ONOFF OFF Disabled 10 2000 OFFOFF ONON Disabled 16 3200 OFFOFF ONOFF Disabled 32 6400 OFFOFFOFF ON Disabled 64 12800 OFFOFFOFFOFF Disabled 1 200 ONONONON Enabled 2 400 ONONONOFF Enabled 5 1000 ONONOFF ON...