Page 11
11 RS232 to RS485 for multiple units or cables longer than 50ft The DPY50601 can be connected to your PC serial port via a RS485 converter (model number: 485SD9TB sold separately). This converter will convert the RS232 voltage signals to the compatible RS485 differential signals. Only one converter box is needed per serial port. Contact the factory or use the website www. anaheimautomation.com for RS485 converter information and sales. Terminating Resistor To eliminate noise on the transmission lines...
Page 12
12 Move Number of Steps: This command causes the motion to start in the direction last specified. This command will move the motor the number of steps given. (Range: 1 to 8388607) Move to Position: The move to position command specifies the next absolute position to go to. The DPY50601 controller automatically sets the direction and number of steps needed to go to that position. (Range: -8388607 to +8388607) Slew: The slew command will accelerate the motor up to maximum speed and continue to run at...
Page 13
13 Jog Inputs: The jog switch inputs are internally pulled up by a resistor making them normally +5 volts. To activate the input, the pin must be grounded to (0VDC). All jog switch inputs are internally clamped to +5V, thus allowing voltages of upto +24VDC to be used. Jog is a manual function. The user can select the direction and speed (fast or slow) by grounding the appropriate combinations of inputs. To jog a motor, it is necessary to ground the jog input for the direction desired. For fast jog,...
Page 14
14 Output on the fly: This special function enables output 1 to turn on during a relative index or absolute move. There are three critical portions of information needed to make this function work correctly. First, output 1 will turn on (0VDC) for a preset delay of 50uS at a specific absolute position set by the 1st output position command. Second, the output can then repeat this after a preset amount of steps set by the number of steps between outputs command, and third a predetermined amount of...
Page 15
15 Encoder Commands: The DPY50601 controller is capable of using a quadrature incremental encoder with A and B channels. Encoder Auto Correct: This command will enable or disable the encoder feature of the DPY50601. When enabled, the encoder function will compare the desired position with the actual encoder position. If it is not in the correct position a correction move will be made. Encoder Delay: This sets the wait time, which is a specified number of milliseconds after a relative index or...
Page 16
16 Section 4: SMC60WIN Software The SMC60WIN software is a handy utility that supports Anaheim Automation’s line of DPY50601’s step motor controllers. Connecting your PC to the DPY50601, via a serial cable, the SMC60WIN software can easily perform the following tasks: • Exercise and monitor the DPY50601 controller • Write and edit stored programs for standalone operation • Directly communicate with the DPY50601 controller Installation Software Windows 2000/XP/Win 7 Installation 1) Open...
Page 17
17 New ProgramStart editing a new program. Open Program Open an existing program from disk. Save Program As Save the current program to disk. Print...Print the current program. ExitExit the SMC60WIN software. File Menu Setup Menu Connect Establish communications with the controller. Disconnect Release the COM port for other devices to use. Com Port Settings Select COM port. AxisSet axis selection and stored axis of the controller. Setup - Axis Menu Select Axis Sets the axis select parameter in the...
Page 18
18 Start ProgramStart the execution of the program in the controller memory. Stop ProgramStop the execution of the program in the controller memory. View Program View the program stored in the controller memory. Clear Program Memory Clear the program memory in the controller. Autostart ProgramTurn the autostart function on or off. Program Menu DisableProgram will disable the execution of a stored program at power up. EnableProgram will start execution when controller is powered up. Program - Autostart...
Page 19
19 “The Unit is Connected” / “The Unit is NOT Connected” On the right of the Toolbar, the user will find the communication status of the DPY50601 controller. If communications are not established, please refer to the Troubleshooting Section. Help Menu Error Coder ReaderUtility to read the error code generated by the DPN10601 controller . PCL601 User’s GuideOpens up the User’s Guide in .pdf format. www.anaheimautomation.com Opens up the Anaheim Automation Website. AboutDisplays the...
Page 20
20 Toolbar Exit New Open Save Print Calculator S\ top All Connect ExitExit the SMC60WIN software. New Start editing a new program. Open Open an existing program from disk or directory. Save Save the current program to disk or directory. Print Print the current program. Calculator Open the desktop calculator. Stop All Stop the program and all motion from running. Connect Establish communication with the controller. Tab Sheets Real Time Motion Monitor and control motion...