Anaheim Discounted Package PKG171DPECBL User Manual
Here you can view all the pages of manual Anaheim Discounted Package PKG171DPECBL User Manual. The Anaheim manuals for Discounted Package are available online for free. You can easily download all the documents as PDF.
Page 1
910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com PKG-171-DPE-CBL System Diagram and Specifications L010875 Included Components: 17Y102S-LW4-MS Stepper Motor DPE25601 2.5Amp Driver Pack with Programmable Indexer CBL-20AWG-04C-010-MS Motor Cable Sheet1 Page 1 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 3.5 7 10.5 14 17.5 21 24.5 28 31.5 35 0 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 POWER (Watts)...
Page 2
FEATURES SPECIFICATIONS 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com The 17Y102S-LW4-MS High Torque Stepper Motor offers a great value without sacrificing quality. This motor was designed to offer the highest possible torque while minimizing vibration and audible noise. It is wired in series with a Molex 4 pin Mini-Fit Jr. receptacle. A 10 ft. 4 conductor, 20 AWG cable with mating 4 pin Mini-Fit Jr. plug is included in the...
Page 3
3 Table of Contents DPE25601 - 2.5Amp Stepper Driver Pack With Programmable IndexerDPE25601 - 2.5Amp Stepper Driver Pack With Programmable Indexer Section 1: Introduction ........................................................................\ ................................................................... 4 Description........................................................................\ ........................................................................\ ................. 4 Electrical...
Page 4
4 Section 1: Introduction The DPE25601 is a single-axis 2.5A bipolar microstep driver/controller, containing 2 Kbytes of nonvolatile stored programming space, quadrature encoder feedback, and a 24W power supply, all enclosed in a package. It provides flexible, independent control of bipolar stepper motors with a current range from 0.5 to 2.5 amps/phase with a microstepping resolution of 1600 steps per revolution from a computer or any machine controller with a serial port. It is also...
Page 5
5 Electrical Specifications Power Requirements: 100-240 VAC 50/60Hz Operating Temperature: 0 to 60 degrees C Pulse Output Range: 1 to 50,000 Hz (0 to 31.25 Rev/Sec) Inputs (TTL-CMOS): Logic “0”: 0 to 0.8VDC Logic “1”: 3.5 to 24VDC Analog input 1: 0 to 5VDC Output Current Rating: 2.5 A/phase maximum running 1.75 A/phase maximum standstillBaud Rate: 38400 Baud, Fixed Data Format: Half-Duplex, 1 start bit, 8 data bits, no parity, 1 stop bit Outputs (8 programmable): Open Drain Type 40V, 100mA +5VDC Output,...
Page 6
6 Slide Switch Descriptions - Controller Switch NumberDescription SW1 This switch is used to select either RS232 or RS485. Connector Descriptions - Controller Switch Number Description P1 This connector is for the RS-232 communication and is labeled RS-232. J1 This connector is for the thumbwheel module and is labeled TWS. PositionDescription - RS485 1 A(-) 2 B(+) 3 IGND - This is an isolated ground for RS485 only Position Description - Encoder 1 +5VDC supply for encoder 2 A channel for encoder 3 B...
Page 7
7 Section 2: Driver Functions Setting the Output Current The output current on the DPE25601 is set by an onboard potentiometer. This potentiometer determines the per phase peak output current of the driver. The specified motor current of 0.71A for the 17Y102S-LW8- MS (which is the bipolar value) is multiplied by a factor of 1.4 to determine the current adjustment potentiometer value of 1.0Amp or 25%. Peak Current Potentiometer Setting Peak CurrentPotentiometer Setting 0.50A 0%1.50A 50% 0.70A 10%1.70A...
Page 8
8 Section 3: Controller Functions Methods of Communication There are two methods for sending commands to the DPN10601. One is to directly talk to the DPN10601 by using Direct Talk Mode. This is usually used with a computer or PLC (Programmable Logic Controller), where the computer or PLC gives the DPN10601 serial commands to off-load its processor. For example: A PLC can utilize its outputs to toggle the DPN10601’s inputs and gain control of variable speeds, variable programs, variable distances,...
Page 9
9 RS232 to RS485 for multiple units or cables longer than 50ft The DPN10601 can be connected to your PC serial port via a RS485 converter (model number: 485SD9TB sold separately ). This converter will convert the RS232 voltage signals to the compatible RS485 differential signals. Only one converter box is needed per serial port. Contact the factory or use the website www. anaheimautomation.com for RS485 converter information and sales. Terminating Resistor To eliminate noise on the transmission lines...
Page 10
10 Move Number of Steps: This command causes the motion to start in the direction last specified. This command will move the motor the number of steps given. (Range: 1 to 8388607) Move to Position: The move to position command specifies the next absolute position to go to. The DPN10601 controller automatically sets the direction and number of steps needed to go to that position. (Range: -8388607 to +8388607) Slew: The slew command will accelerate the motor up to maximum speed and continue to run at...