MDC010 - 050101 50V, 10A Brushless Controller User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION June 2013L010678
Page 2
General Description The MDC010-050101 has a very compact design with a high efficiency speed controller that offers a operating voltage of 50VDC, while maintaining an output current of 5A. The amplifier also offers a large number of inputs and outputs such as the speed monitor, current limiting, speed ranges, direction of rota- tion presetting, enable, operating status, etc. While offering all these features the MDC010-050101 offers many protective features against overcurrent,...
Page 3
Specifications Electrical Data Nominal Supply Voltage (V) - 6-50VDC Absolute Minimum Supply Voltage (V) - 6VDC Absolute Maximum Supply voltage (V) - 55VDC Max. Output Voltage - 0.95V Continous Output Current (I) - 5A Max. Output Current (I) - 10A Switching Frequency - 46.8kHz Max. Speed (motor with 1 pole pair) - 80,000rpm Inputs Set value Speed - Analogue input (0-5V); Resolution: 1024 Steps Enable - +2.4-+55V (R=100kohms) or switch against V Direction - +2.4-+28V(R=100kohms) or switch against V...
Page 4
Inputs Speed Range and Mode selection with and > The digital inputs [20] and [21] determine both, the operation mode (digital speed controller or digital sepeed actuator) and the speed range in speed set\ value mode. DigIN1DigIN2 1 Pole Pair 4 Pole Pair 8 Pole Pair 0 0Open Loop Speed Control, 0-95% PWM Depending on the Input Voltage 1 0500-5,000 rpm 125-1,250 rpm 62-625 rpm 0 1500-20,000 rpm 125-5,000 rpm 62-2,500 rpm 1 1500-80,000 rpm 125-20,000 rpm 62-10,000 rpm Please Note If the signal level...
Page 5
DigIN1DigIN2 1 Pole Pair 4 Pole Pair8 Pole Pair 0 0Open Loop Speed Control, 0-95% PWM Depending on the Input Voltage 1 0500-5,000 rpm 125-1,250 rpm62-625 rpm 0 1500-20,000 rpm 125-5,000 rpm62-2,500 rpm 1 1500-80,000 rpm 125-20,000 pm 62-10,000 rpm Note If the level of the digital inputs DigIN1 [20] and DigIN2 [21] are changed, the new levels are adopted by a disable-enable procedure. Set Value Voltage Description 0-0.1V Operation at minimum speed 0.1-5.0V Linear speed adjustment The actual speed value...
Page 6
The input enables or disables the power stage. If a voltage higher than 2.4V is applied to the input, the amplifier is acti- vated (Enable). A speed ramp will be performed during acceleration. Enable Input Voltage>2.4V Motor Shaft Running If the input is not connected (floating) or ground potential is applied to the input, the power stage is high impedant and the motor shaft freewheels and slows down (Disable). Disable Input not connected (floating) Input set to Gnd Input Voltage
Page 7
The input is used for setting the continuous output current limitation in the range of 0.5-10A. The current set at the input sill stay available for an indefinite period of time. Note The limiting calue should be below the rated motor current (max.continu\ ous current). Set Value Current Pin Number [25] Referenced to Ground Pin Number [24] To parameterize the preferred current limiting value, an external resistor (at least 62.5 mW) between current limiting input Pin [25] and ground...
Page 8
Outputs +5 VDC Output Voltage An internal auxiliary voltage of +5VDC is provided for: - Hall Sensor supply coltage - For external set value potentiometer (recommended value: 10kohms) - Gating the signals: and The output is protected against continuous short circuit. +5 VDC Output Voltage Pin Number [25] Referenced to Ground Pin Number [24] Output Voltage +5VDC 5% Max. Output Current 35mA Motor Speed Monitor The output gives information on the actual speed of the motor shaft. The actual...
Page 9
Status Indication The output can be used to report the state of operational readiness or a fault condition to a master control unit. In normal cases (no fault) the output is switched to 5V.Ready (no fault) 5V In case of a fault the output is switched to Ground. Fault (not ready) 0V (Gnd) Possible reasons for a fault message: UndervoltageFault message occurs in case supply voltage +V56VDC. To reset the fault condition the amplifier must be disabled and the power stage temperature must fall below...
Page 10
Protective Features Undervoltage Protection The power stage will be disabled in case the supply voltage +V cc drops below 6VDC. To reset the fault condition the amplifier must be disabled and the supply voltage +V cc must be higher than 6VDC. Overvoltage Protection The power stage will be disabled in case the supply voltage +V cc rises above 56VDC. To reset the fault condition the amplifier must be disabled and the supply voltage +V cc must be lower than 54VDC. Thermal Overload Protection The power...