    Figure 4-5. Circuit Test Point Diagram  
    						
    							4--12. TRANSMITTER AND MODULATOR. 
     
    4--13. DYNAMOTOR UNIT. 
     
    4--14. PRELIMINARY INSTRUCTIONS: All tests on the transmitter will be performed using the 
    AN/GRM-1 Test Setup optional wiring, illustrated in Figure 1--3, or the AN/ARC-5 Test Bench 
    Harness. Select transmitter one or two, corresponding to the desired units position in the test rack. 
    (See figure 4--15.) 
     
    STEP TEST 
    POINT TEST 
    EQUIPMENT 
    CONTROLS NORMAL INDICATION POSSIBLE 
    CAUSES OF 
    ABNORMAL 
    INDICATION 1. F Emission selector 
    switch to CW. 
    TRANS. POWER 
    switch to ON. 
    Switch on TS-58 
    set to position 1. Filaments light; relays 
    K-5O, K-53, and K-54 
    energized; dynamotor 
    runs. TS-58 meter 
    indicates 54 (27 volts). Fuses F-50 and F-5I 
    blown; defective 
    coils on relays; dirty 
    or corroded 
    contacts; defective 
    dynamotor. 2. G Switch on TS-58 
    set to position 3. 
    Key the 
    transmitter. TS-58 meter reads 51-
    55 (510-550 volts d-c.) Defective relay K-52; 
    defective dynamotor 
    windings; shorted C-
    55; shorted 
    components in 550-
    volt circuit; defective 
    plugs and jacks on 
    equipment.  
    						
    							Figure 4-6. Circuit Test Points  
    Figure 4-7. Converter Circuit Test Points  
    						
    							Figure 4-8. Converter Circuit Test Points  
    Figure 4-9. Antenna Circuit Test Diagram  
    Figure 4-10. Antenna Circuit Test Points  
    Figure 4-11. Typical Transmitter, Top View, Shield Removed  
    						
    							4--15. OSCILLATOR.  
     
    (Follow chart below.) 
    STEP 
    TEST 
    POINT TEST 
    EQUIPMENT 
    CONTROLS NORMAL 
    INDICATION POSSIBLE 
    CAUSES OF 
    ABNORMAL 
    INDICATION 1.  
     Emission selector 
    switch to CW. Set 
    VTVM on 120-volt 
    d-c scale, --polarity 
    and connect to 
    TEST  
    POINT H, the 
    ungrounded 
    terminal of PA grid 
    resistor, R-74 and 
    chassis. TRANS. 
    POWER switch to 
    ON. depress the 
    Microphone 
    button. See figure 
    4--17. VTVM should indicate -
    40 to -70 volts d-c grid 
    bias, if oscillator is 
    supplying proper 
    excitation to PA grid 
    circuit.  Defective oscillator 
    tube or circuit 
    components 
    defective relay K-53; 
    defective PA tubes; 
    open R-74; low 
    voltage on oscillator. 2. 
      Set switch on TS-
    58 to position 4. 
    Depress the 
    Microphone 
    button.  TS-58 meter should 
    read 32-46 (16 to 23  
    ma. oscillator plate 
    current.)  Same as above; 
    oscillator not 
    oscillating; open R-
    68, shorted C-58A. 3. 
      Tune transmitter 
    FREQUENCY  
    dial to calibrator 
    crystal frequency. 
    Depress the 
    Microphone 
    button. Maximum shadow angle 
    on the Magic  
    Eye tube screen as the 
    FREQUENCY  
    dial is rotated to the 
    crystal frequency.  Same as above; 
    defective Magic 
    Eye tube; defective 
    crystal; no or low 
    voltages.  
    						
    							 
    Figure 4-12. Typical Transmitter, Bottom View  
    Figure 4-13. Modulator, Type MD-7/ARC-5, Bottom View  
    						
    							 
    Figure 4-14. Typical MD-7/ARC-5 Modulator  
    Figure 4-15. Transmitter and Modulator Test Points  
    						