Page 11
1 FT-227-A MT-70/ARC-5 Mounting for MT-71/ARC-5 Radio transmitter rack 1 FT-225-A MT-76/ARC-5 Mounting (modulator) 1 FT-229-A MT-77/ARC-5 Mounting (antenna relay unit) 1 Mounting Plate FT-228-A MT-80/ARC-5 Mounting (transmitter control C-29/ARC-5 or C-50A/ARC-5) 1 FT-222-A MT-98/ARC-5 Mounting (Receiver control C- 43/ARC-5) 1 Mounting Rack FT-277-A MT-63/ARC-5 Rack for two radio receivers 1 MT-71/ARC-5 Rack for two radio transmitters 1 Test Unit I-104-A Test unit for radio receivers 1 TS-...
Page 16
NOTES 1. If Antenna relay unit RE-2/ARC-5, being tested, does not have a series capacitor, connect the transmitter to TRANS. Connect ANT of the antenna relay unit to terminal A, instead of to terminal 5, of antenna A-61-A. 2. Test Unit I-104-A normally is used with adapter cord CD-706 as shown. It may be used by attaching cord CD-532 to either position of the receiver rack and when so employed, the meter will not indicate when the meter switch is in position four or five. Volume control on AVC...
Page 17
SECTION II PERFORMANCE CHECKS 2--1. GENERAL. 2--2. These PERFORMANCE CHECKS are to be made in the order given; when a performance requirement is not met, a reference is made to the appropriate voltage measurement or signal tracing procedure in TROUBLE ISOLATION. ALIGNMENT PROCEDURES are included, but are to be used only as directed in TROUBLE ISOLATION. Signal tracing techniques are used after voltage readings have been found to be normal. The standard maintenance manual should be referred to...
Page 18
2--8. TEST PROCEDURE. STEP HEAD TEST SET METER SW CIRCUIT MEASURED NORMAL VALUES NORMAL METER INDIC. ABNORMAL METER INDIC. 1 I-I04- A 1 Input voltage 27.5 v 56 2 I-I04- A 2 Input current 1.4-1.7 a 14-17 3 I-I04- A 3 Plate supply 230-250 v 46-50 4 I-I04- A 4 Screen supply 76-100 v 38-50 5 I-I04- A 5 Cathode current RF and 1st IF tubes 11-15 ma 44-60 Refer to TROUBLE ISOLATION PROCEDURE, Section IV, Paragraph 4-1. 2--9. BAND NOISE. 2--10. LIMITS: (Less than 15 milliwatts.)...
Page 19
2--12. SENSITIVITY. 2--13. LIMITS. Less than 10 uv R-F input to obtain 10 mw audio output with INCREASE OUTPUT control set at maximum. 2--14. TEST PROCEDURE. STEP RECEIVER SETTINGS SIG. GEN CONNECTIONS OUTPUT INDIC. & CONNECTIONS NORMAL INDICATION POSSIBLE CAUSES OF ABNORMAL IND. 1 FREQUENCY at high end; MCW operation: INCREASE OUTPUT control at maximum. Through .006 mfd capacitor, to receiver Antenna post. Set frequency to agree with receiver. Output meter, OP-182, and...
Page 20
2--15. SELECTIVITY. 2--16. PRELIMINARY ADJUSTMENTS: Set the Model 695 output meter to the 1.5 volt range. Connect a 300-ohm one-half or one watt composition resistor in parallel with the output meter; connect output meter to receiver phone jack. Set the receiver INCREASE OUTPUT control to full counterclockwise position. Tune the receiver and the signal generator to the proper frequency, as given in Table below. Adjust the signal generator attenuators for 50 microvolts output, 30 per cent modulated...