Users Guide 20 OPERATING INSTRUCTIONS Figure 14 - Switches and Indicators Switch, Indicators and Connections Device name Function Usage On/Off switch (power switch)Controls printer powerOn – normal operation Off – loading paper and ribbon Press once to advance a label. Press and Hold while powering on to run Label Sensor Calibration test. Continue to press and hold to print out the self- test pattern and enter into Hex mode. FEED buttonAdvances the media stock to first printing position of next label Press to continue, when READY LED is blinking. READY indicatorShows the printer statusGreen – printer is ready to operate Blinking – printer is paused; press “FEED” button to continue operation POWER indicatorShows the power and error statusOff – printer power off Green – printer power on Blinking – error has occurred Power jack Connected to power adapterConnected with power supply transformer plug RS-232 serial port Communication Connected to host (RS-232 COM port), terminal or KDU Parallel port Communication Connected to host (Centronics ) Top cover Protects the printer media and ribbonLift and reach the media/ribbon compartment Power LED Ready LED Feed button Serial Port Power Jack Parallel Port On Switch
Users Guide 21 Label Sensor Calibration Procedure The Label Sensor Calibration procedure allows the printer to calibrate the Label Sensor to the media type and length being used. The Label Sensor in this procedure looks at the back of the media sensing for: Black Bar Media Gap Media Or, Continuous Feed Media 1. Power the printer on while pressing the Feed button on the front panel. 2. When the feed motor begins moving, release the “FEED” button. 3. The printer will feed approximately 12 inches of blank media. 4. Once the printer has stopped feeding the user can, open the printhead module and manually reverse feed the media back to the first label. 5. Press the Feed button again to align the media to the top of the next label. Notes: These steps are very important and must always be carried out after the first installation and each time the media type (color, size, backing, etc) is changed. Failure to run the Label Sensor Calibration test may result in the label registration errors and label-empty detection being incorrect.
Users Guide 22 Printers Internal Self Test Procedure and Configuration Report 1. Make sure that media is installed. 2. Press and hold down the Feed Button while powering on the printer. 3. The printer will begin the Label Sensor Calibration test. 4. Continue to hold the Feed button until the Self Test begins. 5. After feeding 12 inches of blank media, the printer will begin printing out the current configuration and font list. 6. The printer will print the following information on the installed media: Firmware version, ROM checksum, RS-232 settings, Thermal transfer/Direct thermal settings, Hardware configuration and, Font types. 7. If the installed emulation is PPLB emulation, the printer will enter character Hex Print Mode. 8. To exit the Hex mode, press the Feed button again. The following pages are examples of the printers Self Test mode. The samples that you print may be different. Before requesting service, if possible, please have this page ready.
Users Guide 23 Self Test Pattern for PPLA Figure 15 - Self Test Sample - PPLA Emulation Emulation designation
Users Guide 24 Self Test Pattern for PPLB Figure 16 - Self Test Sample - PPLB Emulation Emulation designation
Users Guide 25 Resetting the Printer to Factory Default Settings Resetting the printer back to Factory settings will set the printers non-volatile memory back to a known condition. To reset the printer to its factory defaults: 1. Printer must be powered On. 2. Press and hold the “FEED” button for about 10 seconds. 3. The “READY” LED will turn off. 4. Release the “FEED” button. 5. The Power LED will then turn off for about 2 seconds after that. 6. When both LED’s turn on again, the printer is reset to the factory default condition. Note: All settings are stored in non-volatile memory and will not be erased even by turning the printer off. After a reset, send to the printer the appropriate commands to re-configure the printers software to the appropriate installed options, and run the Label Sensor Calibration test. Entering into HEX Print mode Hex Print mode is a valuable tool for solving programming print issues. It can be used to determine if the printer is receiving the correct information and if the printer is receiving any extra control codes. Note: Hex mode is only available when PPLB emulation is installed. 1. Make sure that media is installed. 2. Power the printer on while pressing the button on the front panel. 3. The printer will begin the Label Sensor Calibration test. 4. Continue to hold the Feed key until the Self Test begins 5. After feeding 12 inches of blank media, the printer will begin printing out the current configuration and font list. 6. The printer will then enter into Hex Print mode. 7. To exit the Hex mode, press the Feed button again.
Users Guide 26 COMMAND QUICK REFERENCE This section lists all software commands of the printer. Command Set for the PPLA System Setting Commands These commands will cause related parameters to be saved in the non-volatile memory. These parameters will be stored unless other commands or a front panel reset changes them. Command Description Parameter Factory default KI4nMedia empty checkn : 0 - disable, 1 - enable.1 KI5nnSet gap lengthnn: 01 to 10 (mm) 1 KI7nSet transfer typen : 0 - direct thermal, 1 - thermal transfer.1 KI8nSet baud raten : 0 - 9600, 1 - 2400, 2 - 2400, 3 - 19200, 4 - 4800, 5 - 38400, 6 - 2400, 7 - 9600 baud.0 KI;n Set standard control code. Set alternative control code.n: 1 - Standard control code 2 - alternate control code1 KI
Users Guide 27 Interaction Commands These commands only apply to the serial port. They allow the host to request the status and configuration of the printer. Command Description Response Contents # Reset Y T A Send a readable status stringY byte 1 : Y - printer busy byte 2 : Y - paper out byte 3 : Y - ribbon out byte 4 : N (always) byte 5 : Y - printing byte 6 : Y - printer paused byte 7 : Y - label presented byte 8 : N (always) B Toggle pause conditionN E Send the number of labels to be printedY 0000 no label left to be printed F Send status byte Yn Same as A, except bit 1 to 8 corresponding to byte 1 to 8 of A. Notes: 1. Control codes for the printer commands. Symbol Code (hexadecimal) XON 11H XOFF 13H STX 02H SOH 01H ESC 1BH LF 0AH CR 0DH 2. There is no space code in the command.
Users Guide 28 System Level Commands Command Description Remarks a Enable page/job echo characters cxxxxSet continuous paper length and disable edge sensor DxxxxxxxMemory dump**xxxxxxx : memory address in HEX value ExxxxSet copy count for stored label e Enable edge sensor F Feed a page fxxxBack feed from top position G Print stored label I Download graphics either PCX, BMP, PCX or HEX format J Set pause for each label j Cancel pause KQ System configuration details L Enter label formatting state MxxxxSet maximum label length m Set measurement in metric n Set measurement in inches OxxxxSet start of print position P Enable data dump Q Clear memory (fonts & graphics) r Select reflective sensor SnSet feed rate for motorn : ‘A’, ‘B’ or ‘C’ T Print test pattern VnSet Cutter or Peel and Present configurationn : ‘1’ - enable cutter, ‘4’ - enable peel and Present v Printer version information WnGraphics/fonts/labels and memory status detailsn : ‘G’, ‘F’ or ‘L’. RS-232 port only x Release file from printer memory Note: **Models FM402DT and FM402TT, the memory dump command only needs a 6-digit hexadecimal.
Users Guide 29 Formatting Commands Command Description :xxxxSet cut amount AnSet print mode n : ‘1’- exclusive, ‘2’ - transparent CxxxxSet horizontal offset cxxSet cut amount DwhSet pixel width and height E Form feed and return to system level command mode G Store previous data to global register SnRetrieve from global register. n : global register ID HxxSet heating value, xx=01 to 20 M Toggle the mirror mode m Set measurement in metric n Set measurement in inches PnSet print speed. n=’A’, ‘B’, or ‘C’ ** QxxxxSet copy count RxxxxSet vertical offset r Retrieve label data from printer buffer. : label name sm Save label data to printer buffer. m : memory module, : label name TxxSet end-of-line code, xx : hex value z Change slash zero to normal zero (0). +xx >xxMake auto increment for numeric or alphanumeric, xx : count -xx