    OPERATING INSTRUCTIONS
    Figure 14 - Switches and Indicators
    Switch, Indicators and Connections
    Device name Function Usage
    On/Off switch
    (power switch)Controls printer
    powerOn – normal operation
    Off – loading paper and ribbon
    Press once to advance a label.
    Press and Hold while powering on to run Label
    Sensor Calibration test.
    Continue to press and hold to print out the self-
    test pattern and enter into Hex mode.
    FEED buttonAdvances the media
    stock to first printing
    position of next label
    Press to continue, when READY LED is
    blinking.
    READY indicatorShows the printer
    statusGreen –   printer is ready to operate
    Blinking – printer is paused; press “FEED”
    button to continue operation
    POWER indicatorShows the power
    and error statusOff – printer power off
    Green – printer power on
    Blinking – error has occurred
    Power jack Connected to power
    adapterConnected with power supply transformer plug
    RS-232 serial port Communication Connected to host (RS-232 COM port), terminal
    or KDU
    Parallel port Communication Connected to host (Centronics )
    Top cover Protects the printer
    media and ribbonLift and reach the media/ribbon compartment
    Power LED
    Ready LED
    Feed button
    Serial Port
    Power Jack
    Parallel Port
    On Switch 
    						
    							Users Guide 21
    Label Sensor Calibration Procedure
    The Label Sensor Calibration procedure allows the printer to calibrate the Label Sensor to the media
    type and length being used.  The Label Sensor in this procedure looks at the back of the media sensing
    for:
    Black Bar Media
    Gap Media
    Or, Continuous Feed Media
    1. Power the printer on while pressing the Feed button on the front panel.
     
    2. When the feed motor begins moving, release the “FEED” button.
     
    3. The printer will feed approximately 12 inches of blank media.
    4. Once the printer has stopped feeding the user can, open the printhead module and manually
    reverse feed the media back to the first label.
    5. Press the Feed button again to align the media to the top of the next label.
    Notes:
    These steps are very important and must always be carried out after the first installation and
    each time the media type (color, size, backing, etc) is changed.  Failure to run the Label
    Sensor Calibration test may result in the label registration errors and label-empty detection
    being incorrect. 
    						
    							Users Guide 22
     Printers Internal Self Test Procedure and Configuration Report
     
    1. Make sure that media is installed.
    2. Press and hold down the Feed Button while powering on the printer.
    3. The printer will begin the Label Sensor Calibration test.
     
    4. Continue to hold the Feed button until the Self Test begins.
     
    5. After feeding 12 inches of blank media, the printer will begin printing out the current
    configuration and font list.
     
    6. The printer will print the following information on the installed media:
    Firmware version,
    ROM checksum,
    RS-232 settings,
    Thermal transfer/Direct thermal settings,
    Hardware configuration and,
    Font types.
     
    7. If the installed emulation is PPLB emulation, the printer will enter character Hex Print Mode.
    8. To exit the Hex mode, press the Feed button again.
    The following pages are examples of the printers Self Test mode.  The samples that you print may be
    different.  Before requesting service, if possible, please have this page ready. 
    						
    							Users Guide 23
    Self Test Pattern for PPLA
    Figure 15 - Self Test Sample - PPLA Emulation
    Emulation
    designation 
    						
    							Users Guide 24
    Self Test Pattern for PPLB
    Figure 16 - Self Test Sample - PPLB Emulation
    Emulation
    designation 
    						
    							Users Guide 25
    Resetting the Printer to Factory Default Settings
    Resetting the printer back to Factory settings will set the printers non-volatile memory back to a
    known condition.  To reset the printer to its factory defaults:
    1. Printer must be powered On.
    2. Press and hold the “FEED” button for about 10 seconds.
     
    3. The “READY” LED will turn off.
    4. Release the “FEED” button.
    5. The Power LED will then turn off for about 2 seconds after that.
    6. When both LED’s turn on again, the printer is reset to the factory default condition.
    Note: All settings are stored in non-volatile memory and will not be erased even by turning the
    printer off.  After a reset, send to the printer the appropriate commands to re-configure the
    printers software to the appropriate installed options, and run the Label Sensor
    Calibration test.
    Entering into HEX Print mode
    Hex Print mode is a valuable tool for solving programming print issues.  It can be used to
    determine if the printer is receiving the correct information and if the printer is receiving any
    extra control codes.
    Note: Hex mode is only available when PPLB emulation is installed.
    1. Make sure that media is installed.
    2. Power the printer on while pressing the button on the front panel.
    3. The printer will begin the Label Sensor Calibration test.
     
    4. Continue to hold the Feed key until the Self Test begins
     
    5. After feeding 12 inches of blank media, the printer will begin printing out the current
    configuration and font list.
     
    6. The printer will then enter into Hex Print mode.
    7. To exit the Hex mode, press the Feed button again. 
    						
    							Users Guide 26
    COMMAND QUICK REFERENCE
    This section lists all software commands of the printer.
    Command Set for the PPLA
    System Setting Commands
    These commands will cause related parameters to be saved in the non-volatile memory.  These
    parameters will be stored unless other commands or a front panel reset changes them.
    Command Description Parameter Factory default
    KI4nMedia empty checkn :  0 - disable,
          1 - enable.1
    KI5nnSet gap lengthnn:  01 to 10 (mm) 1
    KI7nSet transfer typen :  0 - direct thermal,
          1 - thermal transfer.1
    KI8nSet baud raten :  0 - 9600,
          1 - 2400,   2 - 2400,
          3 - 19200, 4 - 4800,
          5 - 38400, 6 - 2400,
          7 - 9600 baud.0
    KI;n Set standard control
    code.
    Set alternative control
    code.n:  1 - Standard control
    code
         2 - alternate control
    code1
    KI
    						
    							Users Guide 27
    Interaction Commands
    These commands only apply to the serial port.  They allow the host to request the status and
    configuration of the printer.
    Command Description Response Contents
    # Reset Y T
    A Send a readable
    status stringY  
    byte 1 : Y - printer busy
    byte 2 : Y - paper out
    byte 3 : Y - ribbon out
    byte 4 : N (always)
    byte 5 : Y - printing
    byte 6 : Y - printer paused
    byte 7 : Y - label presented
    byte 8 : N (always)
    B Toggle pause
    conditionN
    E Send the number of
    labels to be printedY 0000
    no label left to be printed
    F Send status byte Yn
    Same as A, except bit 1 to 8
    corresponding to byte 1 to 8 of
    A.
    Notes:
    1.    Control codes for the printer commands.
    Symbol Code (hexadecimal)
    XON 11H
    XOFF 13H
    STX 02H
    SOH 01H
    ESC 1BH
    LF 0AH
    CR 0DH
    2.   There is no space code in the command. 
    						
    							Users Guide 28
    System Level Commands
    Command Description Remarks
    a Enable page/job echo characters
    cxxxxSet continuous paper length and
    disable edge sensor
    DxxxxxxxMemory dump**xxxxxxx : memory address in
    HEX value
    ExxxxSet copy count for stored label
    e Enable edge sensor
    F Feed a page
    fxxxBack feed from top position
    G Print stored label
    I Download graphics either PCX, BMP, PCX
    or HEX format
    J Set pause for each label
    j Cancel pause
    KQ System configuration details
    L Enter label formatting state
    MxxxxSet maximum label length
    m Set measurement in metric
    n Set measurement in inches
    OxxxxSet start of print position
    P Enable data dump
    Q Clear memory (fonts & graphics)
    r Select reflective sensor
    SnSet feed rate for motorn :  ‘A’, ‘B’ or ‘C’
    T Print test pattern
    VnSet Cutter or Peel and Present
    configurationn : ‘1’ - enable cutter,
         ‘4’ - enable peel and
    Present
    v Printer version information
    WnGraphics/fonts/labels and memory
    status detailsn : ‘G’, ‘F’ or ‘L’.
          RS-232 port only
    x Release file from printer memory
    Note: **Models FM402DT and FM402TT, the memory dump command only needs a 6-digit
    hexadecimal. 
    						
    							Users Guide 29
    Formatting Commands
    Command Description
    :xxxxSet cut amount
    AnSet print mode
    n : ‘1’- exclusive, ‘2’ - transparent
    CxxxxSet horizontal offset
    cxxSet cut amount
    DwhSet pixel width and height
    E Form feed and return to system level command mode
    G Store previous data to global register
    SnRetrieve from global register.  n : global register ID
    HxxSet heating value, xx=01 to 20
    M Toggle the mirror mode
    m Set measurement in metric
    n Set measurement in inches
    PnSet print speed.  n=’A’, ‘B’, or ‘C’ **
    QxxxxSet copy count
    RxxxxSet vertical offset
    r Retrieve label data from printer buffer.   : label name
    sm Save label data to printer buffer.  m : memory module,
     : label name
    TxxSet end-of-line code, xx : hex value
    z Change slash zero to normal zero (0).
    +xx
    >xxMake auto increment for numeric or alphanumeric,
    xx : count
    -xx
    
    						
    All AMT Datasouth manuals Comments (0)

    Related Manuals for AMT Datasouth Printer Fastmark 400 Users Guide