    5200 User’s Manual
    Lamp Module
    DisposalThe lamp inside the lamp module is under great pressure. DO NOT incinerate.
    !
    WARNING! 
    Eye protection should be worn when working with the lamp to avoid
    injury from metal particles.
    If Desired, pressure can be relieved by any means of breaking the copper tubular seal on
    the back of the lamp. Pliers and wire cutters work well to break the seal.
    Lamps can be discarded as landfill garbage. However, the lamp operation timer contains
    a small amount of mercury and must be treated as hazardous waste if discarded in
    volume.
    Illustrations
    Rear View
    
    
    
    
    HIGH-PRESSURE LAMP MAY EXPLODE IF
    IMPROPERLY HANDLED.  REFER SERVICING TO
    QUALIFIED SERVICE PERSONNEL. 
    						
    							50
    5200 User’s Manual
    ALICE Help Guide 1
    If your ALICE projector operating system is not working as expected, and you are not sure of what to do,
    start with this guide. This guide directs you through some initial checks and basic troubleshooting.
    Start Symbol – Indicates
    the beginning of a help
    map.Off-Page-Connector –
    Connects parts of a help
    map that extends across two
    or more pages. Help Chart
    Conventions
    Process Box – Encloses
    an action that needs to be
    performed.Document – refers to a
    document or procedure
    relating to a particular point.
    Analyzing
    SymptomsStart troubleshooting by analyzing the symptoms to determine a strategy for resolving the
    problem
    Consider the following;
      Has the system or configuration ev er worked? If so, what changed?
      Is the error condition reproducible or random?
      Is the error specific to a particular system, configuration, or application?
      What particular hardware or firmware is involved?
      Are any non-Windows 95 device drivers or TSRs loaded?
      Does the order by which drives or application start-up make a difference?
      Does the error still occur with Safe Mode, or Safe Mode w/Network Support?
      For additional information relevant to Windows® 95 configuration and operation,
    please refer to the reference material included with your system.
    Start
     Step 1. If desired, connect an external monitor to the VGA “out” port
      The VGA “out “ port connector is located on the PC card cage. Open the front
    access door. The VGA “out” port is in the XXX slot from the right as viewed from the
    front, table mounted.
     Step 2. Apply main AC to the projector and toggle the main AC switch to the “on”
    position.
     Monitor the boot sequence.
     The normal boot-up sequence for the ALICE projector is as follows:
      The AmPro 5200 follows an initial “power-up” sequences from the time the main AC
    is toggled “on” to the time an image is displayed.
      With the two IR Receiv ers connected, plug the main power cord into the receptacle.
    Toggle the main AC switch to the “on” position. The projector will automatically start,
    first displaying the custom Windows boot-up screen, and then the Scan Disk
    operation will be evoked.
      Once the Scan Disk operation has completed, the projector will automatically start
    the ALICEXGA program and all associated programs.
      Once all programs have booted, an automatic search for an external source will
    start. If an external source is present, the projector will auto-select or auto-setup the
    source. If no external source is present, the projector will switch to the internal
    graphic channel.
      NOTE; if more than one external source is present, the projector will switch to the
    “last source” selected prior to the last shutdown. 
    						
    							ALICE Help Guide 1
    51
    5200 User’s Manual
    Flow
    Chart 1Boot-Up 
    Problem 
    Did thesystem boot properly
    Press DELETE to enter the main BIOS screen
    Are thesettingscorrect?
    Correct the settings
    SeeBIOSConfigurationProcedure
    Is theproblemresolved?
    No
    No
    Turn the projector off (toggle the main AC switch off).Disconnect the main AC power cord from the projector.Lossen the two captive screws located on either side of the projector towards the front.Lift up and lock the top cover in place.Remove the PC cover-remove the six (6) #6 phillips screws securing the cover in place.Check to see if the IDE power, control and data cables are properly connected.Check system boards and make sure all are well seated in place.Be Sure that no cable or any other objects are making contact with the CPU fan
    No
    Yes
    Replace the PC card cage cover, reconnect the system AC and turn the main AC switch on.
    Apply AC power to the projector. Toggle the projector on. Verify the boot sequence.
    Be sure that the IR Keyboard/Mouse and the IR remote Mouse are properly connected.
    1Yes
    Yes
    2
    If desired, connect an 
    external monitor to the 
    projector VGA out 
    connector. 
    						
    							ALICE Help Guide 1
    52
    5200 User’s Manual
    Flow
    Chart 2
    Did the system boot correctlyYES
    Does Windows 95 Start properly
    Re-boot the system and enter the Windows 95Safe Mode of operation (press F8 at the StartingWindows 95 message.)
    NO
    Did thesystem restart  in Safe Mode
    See Safe Mode Operation
    No
    YES
    Did the MindPath and/or the ALICE program st art.
    Does it start in SAFE MODE of operation
    NO
    YES
    Contact the manufacturer for additional help.
    NO
    YES
    2
    1
    3
    Click START then RUNType SYSEDIT then click OKClose autoexec.bat and config.sys windows. Verify that the following statements are present in your Win.ini file;LOAD=C:\MPFX32\MPFX32.EXERUN=C:\ALICE\ALICE XGA.EXEIf the above two statements do not appear in the Win.ini file, then enter them at this time.
    Reboot the syst em
    Did the MindPath and/or the ALICE program start.
    Contact the manufacturer for additional help.
    NO
    Go to SYSEDIT
    *
    Re-enter the Data
    NO
    YES
    YES
    *DO NOT HOT BOOT THE SYSTEM 
    						
    							ALICE Help Guide 1
    53
    5200 User’s Manual
    Flow
    Chart 3
    Does the IR Remote/Mouse work properly
    Does the IR Keyboard and Mouse work properly
    Are the batteries good.
    Repl ace t he batteries
    NO
    Does the IR Remote/Mouse work properly
    Are the batteries good.
    Is the Remote receiver connected to the correct port
    No
    Turn the projector offToggle main AC offDisconnect main AC plug.Connect properly and reboot
    NO
    Does the IR Remote/Mouse work properly now
    Remote/Mouse 
    Problem
    Keyboard/Mouse 
    Problem
    NO
    Repl ace t he batteries
    NO
    Does the IR Keyboard and Mouse work properlyEND
    Is the Keyboard and Mouse connected properly
    Does the IR Remote/Mouse work properly
    NO
    YES
    Does the IR Keyboard and Mouse work properly
    If available, connect another Keyboard/Mouse and retry.NOTE: A Standard wired IBM keyboard and seri al  mous e may be used
    Does the IR Keyboard and Mouse work properly
    *DO NOT HOT BOOT THE SYSTEM
    *Turn the projector offToggle main AC offDisconnect main AC plug.Connect properly and reboot
    *
    NO
    YES
    YES
    YES
    YES
    NO
    NO
    YES
    NO
    YES
    Turn off the MindPath programCopy the FX.pro file from the ALICE folder into the MPFX32 folder.Re-start the MindPath program.
    3
    Contact the manufacturer for additional help.
    NONO
    YES
    YES
    YES
    YES
    YES 
    						
    							ALICE Help Guide 1
    54
    5200 User’s Manual
    BIOS
    ConfigurationPress  to enter the main BIOS screen and check the following parameters
     IDD HDD AUTO DETECTION
      Select the setting that includes LBA mode
      Press  three more times and answer NO to each prompt.
     STANDARD CMOS SETUP
      Be sure primary type = user, mode = LBA, and reported drive size corresponds to
    actual drive size.
      Enter correct date and time
      Set HALT ON to NO ERRORS
      Set drive A to 1.44M, 3.5 in.
      Set VIDEO to EGA/VGA
     BIOS FEATURES SETUP
      Boot sequence is C, A
      Boot UP Num Lock is 
    OFF
      P/S2 mouse function is enabled
      Exit to Main menu
     CHIPSET FEATURES SETUP
      Auto configuration is 
    enabled
      DRAM timings is 60ns
     System cacheable is 
    enabled
      Video BIOS cacheable is enabled
      Exit to Main menu
     POWER MANAGEMENT SETUP
      Power Management is 
    disabled
      Exit to Main menu
     PNP/PCI Configuration
      Resources Controlled By is 
    Auto
      Exit to Main menu
     INTERGRATED PERIPHERALS
      IDE HDD Block mode;………….….………..….
    enabled
      IDE PIO for all four ports;………….………..….enabled
      On Chip Primary and Secondary PIO;…….….enabled
      PCI slot IDE 2nd channel;………….………..….disabled
      Onboard FDC controller;………….………..…..enabled
     Onboard UART1;………….………..…………..3F8, IRQ4
     Onboard UART2;………….………..…………..2F8, IRQ3
      Onboard Parallel Port;………….………..…….378, IRQ7
      Parallel Part Mode;………….………..………..normal or SPP
      Exit to Main menu
    Select SAVE & EXIT, then enter “Y” to the resulting dialog box. System will now re-boot. 
    						
    							ALICE Help Guide 1
    55
    5200 User’s Manual
    Safe Mode
    OperationWindows® 95 will automatically initiate Safe Mode if it detects that the system start-up has
    failed, for example if the Registry is corrupted, or an application has requested Safe Mode.
    Sporadically, Windows® 95 will start Safe Mode for no apparent reason. If this is the case,
    simply rebooting the system will resolv e the problem.
    To access Windows® 95 Startup Menu, when you see the message “Starting Windows 95 ,”
    press F8.
    At times, simply pressing “NORMAL” at the Startup Menu will resolve the problem.
    Use Safe Mode for system startup situations such as the following
      If Windows® 95 fails to start after the “Starting Windows 95” message appears.
      If Windows® 95 seems to stall for an extended period.
      Windows® 95 doesn’t work correctly or has an unexpected result.
      If you cannot print to a local printer after attempting other troubleshooting steps.
      If your video display doesn’t work properly. In the case of the ALICE, connect an
    ex ternal m onitor.
      If your computer stalls repeatedly. 
    						
    							AmPro Corporate Office and Florida
    Operations
    525 John Rodes Boulevard
    Melbourne, FL  32934
    Phone: 407-254-3000
    Toll Free: 800-254-3001
    Fax: 407-253-3001
    E-mail: [email protected] or
                  [email protected]
     
    AmPro Light Valve Products
    420 N. Bernardo Avenue
    Mountain View, CA 94043
    Phone: 650-962-8281
    Fax: 650-962-8295
    AmPro Prosumer Products
    175-G New Boston Street
    Woburn, MA 01801
    Phone: 781-932-4800
    Toll Free: 800-556-7733
    Fax: 781-932-8756
    AmPro Europe
    Glebelands House
    Silchester Road
    Bramley, Hampshire  UK  RG26 5DQ
    Phone: 44-1256-880777
    Fax: 44-1256-881145
    E-mail: [email protected]
    AmPro Pacific Rim
    2/F D Capital Trade Centre
    No. 62 Tsun Yip Street
    Kwun Tong Kowloon, HK
    Phone: 852-2797-3998
    Fax: 852-2797-3213 
    						
    All Ampro Corporation manuals Comments (0)