Ampro Corporation Ampro Projector 5200 User Manual
Have a look at the manual Ampro Corporation Ampro Projector 5200 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1 Ampro Corporation manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
49 5200 User’s Manual Lamp Module DisposalThe lamp inside the lamp module is under great pressure. DO NOT incinerate. ! WARNING! Eye protection should be worn when working with the lamp to avoid injury from metal particles. If Desired, pressure can be relieved by any means of breaking the copper tubular seal on the back of the lamp. Pliers and wire cutters work well to break the seal. Lamps can be discarded as landfill garbage. However, the lamp operation timer contains a small amount of mercury and must be treated as hazardous waste if discarded in volume. Illustrations Rear View HIGH-PRESSURE LAMP MAY EXPLODE IF IMPROPERLY HANDLED. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
50 5200 User’s Manual ALICE Help Guide 1 If your ALICE projector operating system is not working as expected, and you are not sure of what to do, start with this guide. This guide directs you through some initial checks and basic troubleshooting. Start Symbol – Indicates the beginning of a help map.Off-Page-Connector – Connects parts of a help map that extends across two or more pages. Help Chart Conventions Process Box – Encloses an action that needs to be performed.Document – refers to a document or procedure relating to a particular point. Analyzing SymptomsStart troubleshooting by analyzing the symptoms to determine a strategy for resolving the problem Consider the following; Has the system or configuration ev er worked? If so, what changed? Is the error condition reproducible or random? Is the error specific to a particular system, configuration, or application? What particular hardware or firmware is involved? Are any non-Windows 95 device drivers or TSRs loaded? Does the order by which drives or application start-up make a difference? Does the error still occur with Safe Mode, or Safe Mode w/Network Support? For additional information relevant to Windows® 95 configuration and operation, please refer to the reference material included with your system. Start Step 1. If desired, connect an external monitor to the VGA “out” port The VGA “out “ port connector is located on the PC card cage. Open the front access door. The VGA “out” port is in the XXX slot from the right as viewed from the front, table mounted. Step 2. Apply main AC to the projector and toggle the main AC switch to the “on” position. Monitor the boot sequence. The normal boot-up sequence for the ALICE projector is as follows: The AmPro 5200 follows an initial “power-up” sequences from the time the main AC is toggled “on” to the time an image is displayed. With the two IR Receiv ers connected, plug the main power cord into the receptacle. Toggle the main AC switch to the “on” position. The projector will automatically start, first displaying the custom Windows boot-up screen, and then the Scan Disk operation will be evoked. Once the Scan Disk operation has completed, the projector will automatically start the ALICEXGA program and all associated programs. Once all programs have booted, an automatic search for an external source will start. If an external source is present, the projector will auto-select or auto-setup the source. If no external source is present, the projector will switch to the internal graphic channel. NOTE; if more than one external source is present, the projector will switch to the “last source” selected prior to the last shutdown.
ALICE Help Guide 1 51 5200 User’s Manual Flow Chart 1Boot-Up Problem Did thesystem boot properly Press DELETE to enter the main BIOS screen Are thesettingscorrect? Correct the settings SeeBIOSConfigurationProcedure Is theproblemresolved? No No Turn the projector off (toggle the main AC switch off).Disconnect the main AC power cord from the projector.Lossen the two captive screws located on either side of the projector towards the front.Lift up and lock the top cover in place.Remove the PC cover-remove the six (6) #6 phillips screws securing the cover in place.Check to see if the IDE power, control and data cables are properly connected.Check system boards and make sure all are well seated in place.Be Sure that no cable or any other objects are making contact with the CPU fan No Yes Replace the PC card cage cover, reconnect the system AC and turn the main AC switch on. Apply AC power to the projector. Toggle the projector on. Verify the boot sequence. Be sure that the IR Keyboard/Mouse and the IR remote Mouse are properly connected. 1Yes Yes 2 If desired, connect an external monitor to the projector VGA out connector.
ALICE Help Guide 1 52 5200 User’s Manual Flow Chart 2 Did the system boot correctlyYES Does Windows 95 Start properly Re-boot the system and enter the Windows 95Safe Mode of operation (press F8 at the StartingWindows 95 message.) NO Did thesystem restart in Safe Mode See Safe Mode Operation No YES Did the MindPath and/or the ALICE program st art. Does it start in SAFE MODE of operation NO YES Contact the manufacturer for additional help. NO YES 2 1 3 Click START then RUNType SYSEDIT then click OKClose autoexec.bat and config.sys windows. Verify that the following statements are present in your Win.ini file;LOAD=C:\MPFX32\MPFX32.EXERUN=C:\ALICE\ALICE XGA.EXEIf the above two statements do not appear in the Win.ini file, then enter them at this time. Reboot the syst em Did the MindPath and/or the ALICE program start. Contact the manufacturer for additional help. NO Go to SYSEDIT * Re-enter the Data NO YES YES *DO NOT HOT BOOT THE SYSTEM
ALICE Help Guide 1 53 5200 User’s Manual Flow Chart 3 Does the IR Remote/Mouse work properly Does the IR Keyboard and Mouse work properly Are the batteries good. Repl ace t he batteries NO Does the IR Remote/Mouse work properly Are the batteries good. Is the Remote receiver connected to the correct port No Turn the projector offToggle main AC offDisconnect main AC plug.Connect properly and reboot NO Does the IR Remote/Mouse work properly now Remote/Mouse Problem Keyboard/Mouse Problem NO Repl ace t he batteries NO Does the IR Keyboard and Mouse work properlyEND Is the Keyboard and Mouse connected properly Does the IR Remote/Mouse work properly NO YES Does the IR Keyboard and Mouse work properly If available, connect another Keyboard/Mouse and retry.NOTE: A Standard wired IBM keyboard and seri al mous e may be used Does the IR Keyboard and Mouse work properly *DO NOT HOT BOOT THE SYSTEM *Turn the projector offToggle main AC offDisconnect main AC plug.Connect properly and reboot * NO YES YES YES YES NO NO YES NO YES Turn off the MindPath programCopy the FX.pro file from the ALICE folder into the MPFX32 folder.Re-start the MindPath program. 3 Contact the manufacturer for additional help. NONO YES YES YES YES YES
ALICE Help Guide 1 54 5200 User’s Manual BIOS ConfigurationPress to enter the main BIOS screen and check the following parameters IDD HDD AUTO DETECTION Select the setting that includes LBA mode Press three more times and answer NO to each prompt. STANDARD CMOS SETUP Be sure primary type = user, mode = LBA, and reported drive size corresponds to actual drive size. Enter correct date and time Set HALT ON to NO ERRORS Set drive A to 1.44M, 3.5 in. Set VIDEO to EGA/VGA BIOS FEATURES SETUP Boot sequence is C, A Boot UP Num Lock is OFF P/S2 mouse function is enabled Exit to Main menu CHIPSET FEATURES SETUP Auto configuration is enabled DRAM timings is 60ns System cacheable is enabled Video BIOS cacheable is enabled Exit to Main menu POWER MANAGEMENT SETUP Power Management is disabled Exit to Main menu PNP/PCI Configuration Resources Controlled By is Auto Exit to Main menu INTERGRATED PERIPHERALS IDE HDD Block mode;………….….………..…. enabled IDE PIO for all four ports;………….………..….enabled On Chip Primary and Secondary PIO;…….….enabled PCI slot IDE 2nd channel;………….………..….disabled Onboard FDC controller;………….………..…..enabled Onboard UART1;………….………..…………..3F8, IRQ4 Onboard UART2;………….………..…………..2F8, IRQ3 Onboard Parallel Port;………….………..…….378, IRQ7 Parallel Part Mode;………….………..………..normal or SPP Exit to Main menu Select SAVE & EXIT, then enter “Y” to the resulting dialog box. System will now re-boot.
ALICE Help Guide 1 55 5200 User’s Manual Safe Mode OperationWindows® 95 will automatically initiate Safe Mode if it detects that the system start-up has failed, for example if the Registry is corrupted, or an application has requested Safe Mode. Sporadically, Windows® 95 will start Safe Mode for no apparent reason. If this is the case, simply rebooting the system will resolv e the problem. To access Windows® 95 Startup Menu, when you see the message “Starting Windows 95 ,” press F8. At times, simply pressing “NORMAL” at the Startup Menu will resolve the problem. Use Safe Mode for system startup situations such as the following If Windows® 95 fails to start after the “Starting Windows 95” message appears. If Windows® 95 seems to stall for an extended period. Windows® 95 doesn’t work correctly or has an unexpected result. If you cannot print to a local printer after attempting other troubleshooting steps. If your video display doesn’t work properly. In the case of the ALICE, connect an ex ternal m onitor. If your computer stalls repeatedly.
AmPro Corporate Office and Florida Operations 525 John Rodes Boulevard Melbourne, FL 32934 Phone: 407-254-3000 Toll Free: 800-254-3001 Fax: 407-253-3001 E-mail: [email protected] or [email protected] AmPro Light Valve Products 420 N. Bernardo Avenue Mountain View, CA 94043 Phone: 650-962-8281 Fax: 650-962-8295 AmPro Prosumer Products 175-G New Boston Street Woburn, MA 01801 Phone: 781-932-4800 Toll Free: 800-556-7733 Fax: 781-932-8756 AmPro Europe Glebelands House Silchester Road Bramley, Hampshire UK RG26 5DQ Phone: 44-1256-880777 Fax: 44-1256-881145 E-mail: [email protected] AmPro Pacific Rim 2/F D Capital Trade Centre No. 62 Tsun Yip Street Kwun Tong Kowloon, HK Phone: 852-2797-3998 Fax: 852-2797-3213