Ampeg Bass heads V50H User Manual
Have a look at the manual Ampeg Bass heads V50H User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 36 Ampeg manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Owner’s Guide for the V-50H Guitar Amplifier Made in the U.S.A. by
THEFRONTPANEL: 1. Power switchis used to turn the amplifier on and off. 2. Power lightindicates the amplifier is turned on by glowing an iridescent blue color. 3. Reverbcontrols the amount of reverbera- tion applied to the signal. With the control at the “0” position there is no reverb applied; as the control is turned towards “10” the amount of reverb increases accordingly.4. Bassadjusts the output level of the low fre- quencies and offers a cut or boost of 24dB at 50Hz. 5. Mid adjusts the output level of the middle frequencies and offers a cut or boost of 16dB at 800Hz. 6. Trebleadjusts the output level of the high frequencies and offers a cut or boost of 12dB at 6kHz. 7. Gain controls the overall output level of the amplifier. At lower volume settings the soundwill be clean. As you push the volume higher and crank your guitar the sound becomes dis- torted. 8. -6dB Inputaccepts a standard 1/4” instru- ment plug from high output electronic instru- ments. This input is padded 6dB to compen- sate for higher output sources. 9. 0dB Input accepts a standard 1/4” instru- ment plug from your electric guitar. This input is at 0dB level. THE REAR PANEL: 10. Main Speaker jack: Use this jack to con- nect the amplifier to your speaker cabinet. Always use this jack “first” – if using a second cabinet, connect it to the Extension Speaker jack (#11). 11. Ext. Speaker jack:Use this jack to con- nect the amplifier to a secondspeaker cabinet – always use the Main Speaker jack (#10) “first.” 12. Impedance switch:Use this switch tomatch the amplifier to the TOTAL impedance of your speaker cabinet(s). 13. Preamp Tube:12AX7A / 7025 (1) 14. Power Amp Phase Splitter Tube: 12AX7A / 7025 (1) 15,16. Power Tubes:EL34 / 6CA7 (2) Replace tubes ONLY with same types! Refer to enclosed publication about Tubes and Tube Amplifiers for additional information. 17: Footswitch Jack:Connect the suppliedfootswitch here for control of the Reverb on/off and a switchable 15dB of gain from 250Hz to 8kHz. 18: Power cordconnects the amplifier to a suitable source of A.C. voltage. This is a grounded, three-wire cord and must be con- nected to a properly grounded outlet. DO NOT attempt to defeat the ground connection of the power cord!If your amp was purchased outside of the United States, see the sticker next to the A.C. connector for its power rat- ings. Follow the above guidelines. Thank you for choosing Ampeg. In order to obtain the best performance from your new ampli- fier we recommend you review the information in this owner’s guide prior to its use. 123456789 V-50H Guitar Amplifier CAUTION AVIS: RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.RISK OF ELECTRIC SHOCK DO NOT OPEN Made in the U.S.A. bySLM ELECTRONICS1400 FERGUSON AVE. / ST. LOUIS, MO 63133WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. SPEAKERS MAIN: USE FIRST FOOTSWITCH REVERB / BOOST ON–OFF EXT IMPEDANCE 16 8 101112131415161817
THIS EQUIPMENT HAS BEEN DESIGNED AND ENGINEERED TO PROVIDE SAFE AND RELI- ABLE OPERATION. IN ORDER TO PROLONG THE LIFE OF THE UNIT AND PREVENT ACCIDEN- TAL DAMAGES OR INJURY, PLEASE FOLLOW THESE PRE- CAUTIONARY GUIDELINES: CAUTION:TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN CHASSIS; DO NOT DEFEAT OR REMOVE THE GROUND PIN OF THE POWER CORD; CONNECT ONLY TO A PROPERLY GROUNDED AC POWER OUTLET. WARNING:TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOIS- TURE. CAUTION:NO USER-SERVICE- ABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SER- VICE PERSONNEL. CAUTION:OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEV- ELS. CONTINUED EXPOSURE TO HIGH SOUND PRESSURE LEVELS CAN CAUSE PERMA- NENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PROTEC- TION IS RECOMMENDED IF UNIT IS OPERATED AT HIGH VOLUME.CAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL “ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.” REFERREZ-VOUS AU MANUAL DUTILISATION UNBEDINGT IN DER BEDIENUNGSANLEITUNG NACHSCHLAGENEXPLANATION OF GRAPHICAL SYMBOLS: EXPLICACION DE SIMBOLOS GRAFICOS: EXPLICATION DES SYMBÔLES GRAPHIQUES:DANGEROUS VOLTAGE “VOLTAJE PELIGROSO” DANGER HAUTE TENSION GEFAHLICHE SPANNUNG== PRECAUCIONRIESGO DE CORRIENTAZO NO ABRA PRECAUCION PARA DISMINUOIR EL RIESGO DE CORRIENTAZO NO ABRA LA CUBIERTA NO HAY PIEZAS ADENTRO QUE EL USARIO PUEDO REPARAR DEJE TODO MANTENIMIENTO A LOS TECHNICOS CALIFICADOS ATTENTIONRISQUE DELECTROCUTION NE PAS OUVRIR ATTENTION: POUR REDUIRE DELECTROCUTION NE PAS ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE NEST REPRABLE PAR LUTILISATEUR. POUR TOUTE REPARATION, SADRESSER A UN TECHNICIEN QUALIFIE. VORSICHTELEKTRISCHE SCHLAGGEFAHR NICHT OFFENEN VORSICHT: ZUR MINIMIERUNG ELEKTRISCHER SCHLAGGEFAHR NICHT DEN DECKEL ABENHMEN. INTERNE TEILE KONNEN NICHT VOM BENUTZER GEWARTET WERDEN. DIE WARTUNG IS QUALIFIZIERTEM WARTUNGSPERSONAL ZU UBERLASSEN. ESTE APARATO HA SIDO DISE- NADO Y CONSTRUIDO PARA PROVEER ANOS DE OPERA- CION SEGURA Y CONFIABLE. PARA PROLONGAR LA VIDA DE ESTA UNIDAD E IMPEDIR DANOS ACCIDENTALES POR FAVOR SIGA ESTAS INSTRUC- CIONES PREVENTIVAS: PRECAUCION:PARA DISMINUIR EL RIESGO DE DESCARGAS ELECTRICAS: (1) NO ABRA LA CUBIERTA, (2) NO ES RECOMENDABLE REMOVER O DESACTIVAR LA PATA DEL POLO A TIERRA DEL CABLE DE CORRIENTE, CONECTE COR- RECTAMENTE A UNA TOMA DE CORRIENTE A TIERRA. ADVERTENCIA:PARA EVITAR DESCARGAS EL ECTRICAS O PELIGRO DE INCENDIO, NO DEJE ESTE APARATO EXPUESTO A LA LLUVIA O HUMEDAD. PRECAUCION: NO HAY PIEZAS ADENTRO QUE EL USUARIO PUEDE REPARAR. DEJE TODO MANTENIMIENTO A LOS TÉCNI- COS CALIFICADOS. PRECAUCION:NUESTROS AMPLIFICADORES PUEDEN PRODUCIR NIVELES DE PRE- SION DE SONIDO ALTO. EXPOSICION CONTINUADA A LOS NIVELES DE PRESION DE SONIDO ALTO PUEDE CAUSA DANO PERMANENTE A SU OIDO. ES ACONSEJADO QUE USE PRECAUCION AL USUARIO Y ES RECOMENDADO PROTEC- CION PARA LOS OIDOS SI LA UNIDAD ES OPERADA A VOLU- MEN ALTO.CET ÉQUIPEMENT AVAIT ÉTÉ INVENTÉ ET ARRANGÉ POUR POURVOIR DES ANNÉES DUSAGE SAUF ET SÛR. POUR PROLONGER LA VIE DE CET APPAREIL ET POUR EMPÊCHER LES DOMMAGES ET LES TORTS ACCIDENTELS, SUIVEZ LES INSTRUCTIONS DE PRÉCAU- TION. AVERTISSEMENT:POUR RÉDUIRE LES RISQUES DÉLEC- TROCUTION: (1) N’OUVREZ PAS LE CHÂSSIS, (2) NE PAS ESSAYER DE SUPPRIMER LA BROCHE CORRESPONDANT À LA TERRE. ATTENTION: POUR RÉDUIRE LES RISQUES DUN FEU OU DÉLECTROCUTION, N’EX- POSEZ PAS LAPPAREIL À LA PLUIE OU À LA MOITEUR. ATTENTION:IL NY A PAS D’ÉLÉMENTS RÉPARABLES DANS LAPPAREIL. CONSULTER UN TECHNICIEN QUALIFIÉ POUR LES RÉPARATIONS. ATTENTION:NOS AMPLIFICA- TEURS SONT CAPABLES DE LA PRODUCTION DES NIVEAUX DE SON DUNE HAUTE PRESSION. LEXPOSITION CONTINUE AUX CES NIVEAUX PEUT CAUSER LA SURDITÉ PERMANENTE. LA PRUDENCE EST ADVISÉ À UTIL- ISATEUR ET LA PROTECTION DES OREILLES EST RECOM- MANDÉ SI LAPPAREIL EST UTILISÉ À UN HAUT NIVEAU DE VOLUME. The V-50H is covered with a durable Tolex material: wipe it clean with a lint-free cloth. Never spray cleaning agents onto the cabinet. Avoid abrasive cleansers which would damage the finish. El V-50H esta cubierto con un material durable Tolex: limpielo con una toalla seca. Nunca rocie el gabinete con sustancias limpiadoras. Evite usar materiales abrasivos con los cuales pueda danar el acabado. Le V-50H est couvert avec «Tolex» un revêtement noir et durable. Essuyez cette matière avec une toile propre et sans charpie. Ne pulvérisez jamais les agents de nettoyage sur lappareil. Evitez les nettoyeurs abrasifs qui peuvent endommager le «Tolex.»
Ampeg is proudly Made in America. ©1997 SLM Electronics, 1400 Ferguson Avenue, St. Louis, MO 63133 U.S.A. V-50H TECHNICAL SPECIFICATIONS: OUTPUT POWER RATING50 Watts RMS @ 5 % THD 8 ohm load 120 VAC SIGNAL TO NOISE RATIO70dB Typical POWER REQUIREMENTS120 VAC, 60Hz, 110VA 100/115 VAC, 50/60Hz, 110VA 230 VAC, 50/60Hz, 110VA GAIN69dB TREBLE12dB Boost and Cut @ 6kHz MID16dB Boost and Cut @ 800Hz BASS24dB Boost and Cut @ 50Hz SIZE AND WEIGHT29.5” W x 11.5” H x 9” D 34 lbs. Ampeg continually develops new products, as well as improves existing ones. For this reason, the specifications and information in this manual are subject to change without notice. Ampeg continuamente desarrolla nuevos productos, así como también mejora los existentes. Por esta razón, las especifaciones é información incluidos en este manual están sujetos a cambios sin previo aviso. Ampeg développe continuellement des nouvels produits, ainsi daméliorer ceux qui existe. Pour cette raison les spécifications et les informations dans ce manuel peuvent se changer sans préavis. P/N 47-277-16 • 09/97