Home
>
American Water Heater
>
Gas Heater
>
American Water Heater NonCondensing Outdoor Natural Gas GT910NIE User Manual
American Water Heater NonCondensing Outdoor Natural Gas GT910NIE User Manual
Here you can view all the pages of manual American Water Heater NonCondensing Outdoor Natural Gas GT910NIE User Manual. The American Water Heater manuals for Gas Heater are available online for free. You can easily download all the documents as PDF.
Page 31
- 31 - *To change the remote controller’s mode from Default Mode to High Temperature Mode, please follow the procedures below (the remote controller must be installed prior to operating these procedures): DO NOT set to 185ºF if you use your water heater in a recirculation system. This will cause damage to the heater and void the warranty. 1. Turn off power to the remote controller by pressing the “ ON/OFF button. 2. Simultaneously p ress and hold both the “ HOT” and...
Page 32
- 32 - FLOW • The flow rate through the water heater is limited to a maximum of 14.5 GPM. • The temperature setting, along with the supply temperature of the water will determine the flow rate output of the unit. • Please refer to the temperature vs. gallons per minute chart on p .5 1 to determine the likely flow rates based on your local ground water temperature and your desired outlet water temperature combination. • Based on the United States Department of Energy method of...
Page 33
- 33 - The dark squares indicate the direction the dipswitches should be set to. TEMPERATURE SETTINGS • The temperature has been preset at the factor y to 120 ºF ( 50 ºC). • There are 8 preset temperatures that you can select from by changing the dipswitch settings on the computer board. If you want to change the set temp erature with dipswitches, please refer to the diagram below. These temperatures are available: 100 ºF, 115 ºF, 1 20 ºF, 135 ºF, 1 45 ºF, 1 55 ºF, 1 65 ºF, and...
Page 34
- 34 - MAINTENANCE AND SERVICE WARNING: Turn off the electrical power supply and close the manual gas control valve and the manual water control valve before servicing. • Clean the cold- water inlet filter. (Refer to diagram below) • Be sure that all openings for combustion and ventilation air are not blocked. • The venting system should be checked annually for any leaks, corrosion, blockages or damage. • The burner should be checked annually for dust, lint, grease or dirt. •...
Page 35
- 35 - GENERAL TROUBLESHOOTING ~ TEMPERATURE and AMOUNT OF HOT WATER ~ PROBLEM POSSIBLE SOLUTIONS It takes long time to get hot water at the fixtures. • The time it takes to d eliver hot water from the water heater to your fixtures depends on the length of piping between the two. The longer the distance or the bigger the pipes , the longer it will take to get hot water . • If you would like to receive hot water to your fixtures quicker, you may want to consider a hot water r...
Page 36
- 36 - ~ WATER HEATER ~ PROBLEM POSSIBLE SOLUTIONS Unit does not ignite when water goes through the unit. • Is th e flow rate over 0. 5 GPM? (p. 30 ) • Check for the fi lter on cold water inlet. (p. 34 ) • Check for reverse connection and cross connection. • If you use the remote controller, is the power button turned on? (p. 30) The fan motor is s till spinning after operation has stopped. • This is normal. After operation has stopped, the fan motor keep s running...
Page 37
- 37 - TROUBLESHOOTING – ERROR CODES • The units are self diagnostic for safety and convenience when trouble shooting. • If there is a problem with the installation or the unit, it will disp lay a numerical error code on the remote controller (if installed) or on the 7- Seg LED of the central computer board and section computer board to communicate the source of the problem. • Consult the following chart for the cause of each error code. Single Unit • The 7-Seg LED...
Page 40
- 40 - Check valve Check valve Air separator Recirculation pump Hot water outlet to fixtures Air Vent Unions Gas supply Ball valves Expansion tank Y-Strainer Cold water inlet Hot W ate r O utl et S Col d W at er I nl et G as I nl e t APPLICATIONS Space Heating Applications WARNING • This water heater is suitable for combination water (potable) heating and space heating and not suitable for space heating applications only. • In order to purge air in water pipes within a...