1 Instruction Manual PRINTED 0316 100270494 PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. COMMERCIAL ELECTRIC WATER HEATERS Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. ® MODELS VSCE32 65H, VSCE32 80H, VSCE32 119R Series 200 INSTALLATION - OPERATION - SERVICE - MAINTENANCE - LIMITED WARRANTY
Page 2
2 SAFE INSTALLATION, USE, AND SERVICE The proper installation, use and servicing of this water heater is extre\ mely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages \ and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others \ who...
Page 3
3 GENERAL SAFETY INFORMATION When servicing this unit, verify the power to the unit is turned off pri\ or to opening the control cabinet door. PRECAUTIONS DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN EXPOSED TO FLOODING OR WATER DAMAGE. Immediately call a qualified service technician to inspect the water heater and to replace any part of the control system which has been under water. If the unit is exposed to the following, do not operate heater until all corrective steps have been made by...
Page 4
4 Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • ANSI - American National Standards Institute • AHRI - Air-Conditioning, Heating and Refrigeration Institute • NEC - National Electrical Code • NFPA - National Fire Protection Association • UL - Underwriters Laboratory PREPARING FOR THE INSTALLATION 1. Read the “General Safety Information” section of this manual first...
Page 5
5 DIMENSIONS AND CAPACITIES DATA TABLE 2 - RECOVERY CAPACITIES Element Wattage (Upper/Lower) INPUT KW U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED F° 36F° 40F°54F°60F° 72F° 80F° 90F°100F° 108F°120F°126F° C° 20C° 22.2C° 30C°33.3C° 40C° 44.4C° 50C°55.5C° 60C°66.6C° 70C° NON-SIMULATANEOUS 3000/3000 GPH34302320 17 15 1412 111010 3.0 LPH12811 5 8577 64 58 5146 433837 4000/4000 GPH45413027 23 20 1816 151413 4.0 LPH17015311 4102 85 77 6861 575149 4500/4500 GPH51463430 25 23 2018 171514 4.5...
Page 6
6 APPROVALS MODEL AND RATING ®All models are listed by Underwriters Laboratories Inc. MODEL NUMBER22U1 COMMERCIAL STORAGE TANK WATER HEATER WATTS LOWER MAX WORKING PRESSURE PSI 1 PH / 3 PH 1 PH 3 PH RATED MEASURED % WATTS INTERLOCK SIMULTANEOUS CAPACITY US GAL STANDBY LOSS TOTAL WATTS CONNECTED SERIAL NUMBER ITEM ID / PART NUMBER WATTS PHASE CIRCUIT VOLTS - AC UPPER LLC
Page 7
7 FEATURES AND COMPONENTS FIGURE 2 INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES. INSTALL SUITABLE DRAIN PANS UNDER WATER HEATERS TO PREVENT DAMAGE DUE TO LEAKAGE. REFER TO WATER HEATER LOCATION ON PAGE 8. INSTALL THERMAL EXPANSION TANK IF CHECK VALVE OR PRESSURE REDUCING VALVE IS USED IN SUPPLY LINE. A CCESS PA NELS ELECTRICAL J UNCTION BOX (ACCESS P ANEL) COLD ANODE DRAI N VA LVE
Page 8
8 FACTS TO CONSIDER ABOUT THE LOCATION The water heater should be located as close as possible to/or centralized to the water piping system. The water heater should be located in an area not subject to freezing temperatures. The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the heater or to lower floors of the structure. When such locations cannot be avoided, a suitable drain...
Page 9
9 INSTALLATION REQUIRED ABILITY Installation and service of this water heater requires ability equivalent to that of a qualified installer or service agency (page 2) in the field involved. Plumbing and electrical work is required. GENERAL The installation must conform with these instructions and the local code authority having jurisdiction and the requirements of the power c o m p a n y. I n t h e a b s e n c e o f l o c a l c o d e s , t h e i n s t a l l a t i o n m u s t c o...
Page 10
10 paragraph. The new valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (15 0 psi = 1,035 kPa) and a discharge c apacit y not less than the water heater Btu/hr or KW input rate as shown on the water heater’s model rating plate. For safe operation of the water heater, the temperature and pressure relief valve must not be removed from its designated opening nor plugged. The temperature-pressure...