1 Instruction Manual PRINTED 1215 323289-005 PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. COMMERCIAL LIGHT DUTY ELECTRIC WATER HEATERS Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. Lowboy 6/10/15/20 Models Series 102 Lowboy 30/40/50 Models Series 110 Tall 30/40/50/66/80/120 Models Series 110 INSTALLATION - OPERATION - SERVICE - MAINTENANCE
Page 2
2 SAFE INSTALLATION, USE, AND SERVICE The proper installation, use and servicing of this water heater is extre\ mely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages \ and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others \ who...
Page 3
3 GENERAL SAFETY INFORMATION When servicing this unit, verify the power to the unit is turned off pri\ or to opening the control cabinet door. PRECAUTIONS DO NOT USE THIS WATER HE ATER IF ANY PART HAS BEEN E X P O S E D T O F LO O D I N G O R W AT E R D A M A G E . I m m e d i a t e l y call a qualified service technician to inspect the water heater and to replace any part of the control system which has been under water. If the unit is exposed to the following,...
Page 4
4 Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • ANSI - American National Standards Institute • AHRI - Air-Conditioning, Heating and Refrigeration Institute • NEC - National Electrical Code • NFPA - National Fire Protection Association • UL - Underwriters Laboratory PREPARING FOR THE INSTALLATION 1. Read the “General Safety Information” section of this manual first...
Page 5
5 DIMENSIONS AND CAPACITIES DATA TABLE 2 - RECOVERY CAPACITIES Element Wattage (Upper/Lower) INPUT KW U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED F° 36F° 40F°54F°60F° 72F° 80F° 90F°100F° 108F°120F°126F° C° 20C° 22.2C° 30C°33.3C° 40C° 44.4C° 50C°55.5C° 60C°66.6C° 70C° NON-SIMULTANEOUS /1500 GPH17151110 8 8 76 655 1.5 LPH 64584338 32 29 2623 211918 /2000 GPH23201514 11 10 98 876 2.0 LPH 85775751 43 38 3431 282624 /2500 GPH28251917 14 13 1110 988 2.5 LPH107 967164 53 48 4338 363230...
Page 6
6 APPROVALS MODEL AND RATING Lowboy-30/40/50 & Tall-30/40/52/66/80/120Lowboy-6/10/15/20 All models are listed by Underwriters Laboratories Inc.
Page 7
7 FEATURES AND COMPONENTS FIGURE 2 This page shows typical water heater installations by model designations. † OVER CURRENT PROTECTION MUST BE SUPPLIED IN WATER HEATER CIRCUIT. CONSULT LOCAL CODE OR CURRENT EDITION OF NEC FOR PROPER INSTALLATION. * INSTALL IN ACCORDANCE WITH ALL LOCAL CODES. INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES. INSTALL SUITABLE DRAIN PANS UNDER WATER HEATERS TO PREVENT DAMAGE DUE TO LEAKAGE. REFER TO WATER HEATER LOCATION ON PAGE 8. INSTALL...
Page 8
8 FACTS TO CONSIDER ABOUT THE LOCATION The water heater should be located as close as possible to/or centralized to the water piping system. The water heater should be located in an area not subject to freezing temperatures. The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the heater or to lower floors of the structure. When such locations cannot be avoided, a suitable drain pan...
Page 9
9 INSTALLATION REQUIRED ABILITY Installation and service of this water heater requires ability equivalent to that of a qualified installer or service agency (page 2) in the field involved. Plumbing and electrical work is required. GENERAL The installation must conform with these instructions and the local code authority having jurisdiction and the requirements of the power c o m p a n y. I n t h e a b s e n c e o f l o c a l c o d e s , t h e i n s t a l l a t i o n m u s t c o...
Page 10
10 paragraph. The new valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (15 0 psi = 1,035 kPa) and a discharge c apacit y not less than the water heater Btu/hr or KW input rate as shown on the water heater’s model rating plate. For safe operation of the water heater, the temperature and pressure relief valve must not be removed from its designated opening nor plugged. The temperature-pressure...