Page 41
www. americanwaterheater .com 41 Natural gas and Propane (LP) main burner with igniter assembly for 38k to 42k Btu/hr models 31 36 38 39 30 33 34 35 32 37 40 Flare Nut †† † Figure 47 37 Natural gas and Propane (LP) main burner with igniter assembly for 47k Btu/hr models 353634 33 32 31 4039 3830 Flare Nut ††† Figure 48 Notes: † The orifi ce on Natural gas models has Right-hand thread, the orifi ce on Propane (LP) models has Left- hand thread. †† For Natural gas models the Flare Nut...
Page 42
42 www. americanwaterheater .com TROUBLESHOOTING GUIDELINES PROBLEM POSSIBLE CAUSE(S) CORRECTION BURNER WILL NOT IGNITE1. Pilot not lit 2. Thermostat set too low 3. No gas 4. Dirt in the gas lines 5. Pilot line clogged 6. Main burner line clogged 7. Defective thermopile 8. Defective gas control/thermostat1. Light pilot 2. Turn temp. dial to desired temperature 3. Check with gas utility company 4. Notify utility-install trap in gas line 5. Clean, locate source and correct 6. Clean,...
Page 43
www. americanwaterheater .com 43 PROBLEM POSSIBLE CAUSE(S) CORRECTION INSUFFICIENT HOT WATER1. Thermostat set too low 2. Sediment or lime in tank 3. Water heater too small 4. Wrong piping connections 5. Leaking faucets 6. Wasted hot water 7. Long runs of exposed piping 8. Hot water piping in outside wall 9. Low gas pressure 10. Leaks or cracks in dip tube 11. Incorrect plumbing/plumbing crossover1. Turn temperature dial to desired setting 2. Drain/flush-provide water treatment if...
Page 44
44 www. americanwaterheater .com STATUS LIGHT AND DIAGNOSTIC CODE TROUBLESHOOTING CHART LED STATUS PROBLEM CORRECTIVE ACTION 0 FLASHES (LED NOT LIT) Pilot light is not lit or thermopile has not yet reached normal operating temperature.Turn Gas Control Valve/Thermostat knob to “OFF”. Wait 10 minutes, then attempt to relight Pilot by following the lighting instructions on the water heater’s label. Until the thermopile reaches its normal operating temperature, the Status Light will not...
Page 45
www. americanwaterheater .com 45 LED STATUS PROBLEM CORRECTIVE ACTION 4 FLASHES The Gas Control Valve’s temperature sensor has detected that the water temperature was too high. Once this condition occurs, the Main Burner and the Pilot Light will be shut off. Since the Pilot light will be off, should this condition occur, this Flash Code will only be displayed immediately after the Pilot has been relit. Turn Gas Control Valve/Thermostat knob to “OFF”.Relight pilot and verify 4...
Page 48