Home > American Water Heater > Gas Heater > American Water Heater 30 Gallon UltraLow NOx Natural Gas Water Heater GU6130T30 User Manual

American Water Heater 30 Gallon UltraLow NOx Natural Gas Water Heater GU6130T30 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual American Water Heater 30 Gallon UltraLow NOx Natural Gas Water Heater GU6130T30 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 32 American Water Heater manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31
    PILOT LIGHT TROUBLESHOOTING CHART 
    Have you bled all the air 
    from the pilot tube and 
    gas supply line?NOWhile repeatedly depressing the igniter 
    button, push in and hold the gas control/
    temperature knob until the pilot is lit and 
    maintains a stable flame, (status light 
    will blink) then release the gas control/
    temperature knob. 
    Section A: Pilot light will not light (new installation).
    Is the manual gas shut-off valve, 
    located in the supply line to the 
    water heater, in the on position?NO
    YES
    Turn the manual gas shut-off valve to 
    the on position and follow the lighting 
    instructions on the front of the water heater.
    Is the igniter producing a 
    spark?YES
    NO
    Follow the “Testing the Igniter 
    System” section in this manual.
    Check for insufficient combustion air.
    Are the combustion air supply and ventilation openings 
    of sufficient size? See “Combustion Air Supply and 
    Ventilation” section in this manual for requirements.
    Is there a furnace/air handler in the same room as the water heater?
    Does the return air duct for the furnace/
    air handler draw its air from a separate 
    location than the water heater? See the 
    “Location Requirements” section and 
    the “Combustion Air Supply” section.
    Is there proper drafting at the 
    drafthood? See “Checking the 
    Draft” section in this manual.
    NO
    Contact a local Heating, 
    Ventilation, Air-Conditioning 
    & Refrigeration authorized 
    service provider to correct 
    the combustion air supply/
    ventilation issue.Correct size of 
    openings to allow 
    sufficient air.
    NO
    YES
    YES
    YES
    NO
    Check the vent 
    system for restrictions/
    obstructions and check 
    the vent termination 
    height. Refer to the 
    “Installation Instructions” 
    section of this manual for 
    specific requirements.
    NO
    Section C: Pilot light will not remain lit.
    Reference the number on the cover of this 
    manual for service information.
    YES
    Set thermostat to desired temperature.
    Section B: Pilot light repeatedly goes out.
    Remove the burner door 
    assembly. Are the flame-trap and 
    burner free from debris due to 
    excessive lint, dirt, dust or oil?Refer to the “Maintenance of 
    your Water Heater” section of this 
    manual for information on cleaning 
    the flame-trap and burner. 
    NO
    YES
    Does the diagnostic status light on the 
    gas control valve/thermostat give 
    a two flash error code?
    Does the flame-trap 
    show signs of 
    discoloration? 
    YES
    Shut-off the gas supply to the water heater at the 
    manual gas shut-off valve, use the number on the 
    cover of this manual to contact Customer Service.
    NOReassemble the heater and attempt to 
    return the heater to service. Does the 
    pilot remain lit?
    YES
    Set to desired temperature.
    NO
    YES
    Refer to the “Replacing the Pilot 
    Assembly” instructions in the manual.
    Reassemble and restore to service. 
    Go to section C. 
    NO
    NOTE: If you are still experiencing diffi culties after 
    following the steps in sections A, B, and C,  
    use the 
    number on the cover of this manual to contact Customer 
    Service
    .
    YES 
    						
    							32
    REPAIR PARTS ILLUSTRATION
    LEGEND
    Special anode rod (see page 22)
    Temperature and Pressure Relief Valve is required, 
    but may not be factory installed
    Unique: Flame Guard™ Safety System parts
    * Pictured on next page.
    1
    7
    5
    9
    10
    8
    4
    16
    6
    When ordering repair parts always give the following 
    information:
    1.  Model, serial, and product number
    2.  Type of gas
    3. Item number
    4. Parts description
    Repair Parts List
    Item
     No.Parts Description
    1 DRAFT HOOD
    2
    REDUCER RING - SOME MODELS 
    (NOT SHOWN)
    3FLUE BAFFLE  (NOT SHOWN)
    4 COMBINATION DIP TUBE/HEAT TRAP NIPPLE
    5 HEAT TRAP/NIPPLE
    6
    ANODE ROD                                                                 
    7 TEMPERATURE  & PRESSURE RELIEF VALVE
    (LOCATED TOP OR SIDE) 
    8 DRAIN VALVE
    9 GAS CONTROL VALVE/THERMOSTAT
     
    10
    OUTER DOOR 
    11
    PILOT/THERMOPILE ASSEMBLY KIT * 
    12 BURNER DOOR ASSEMBLY *
    (NATURAL GAS/ULTRA LOW Nox) 
    13
    BURNER DOOR GASKET *
     
    14 TEMPERATURE SENSOR *
    15 FLEX MANIFOLD TUBE *
    16 WRAP AROUND AIR  FILTER
      
    						
    							33
    Listed Parts Kits and Illustrations
    Item 11:   Pilot assembly kit, which contains the pilot, electrode, and thermopile (Natural Gas)
     Item 12:  Burner Door assembly, which contains the burner, gasket, door, pilot tube, manifold component block with 
    retainer clip, temperature sensor, and pilot assembly. (Natural Gas/Low Nox)
    Item 13:  Contains burner door gasket
    Item 14:  Contains temperature sensor 
    Item 15:   Contains flexible manifold tube
    Item #1112
    Item # 14 Item # 13
    Item # 15 
    						
    							35
    NOTES 
    						
    							36
    Copyright © 2013 American Water Heater Company.  All Rights Reserved. Printed in the U.S. 
    						
    All American Water Heater manuals Comments (0)

    Related Manuals for American Water Heater 30 Gallon UltraLow NOx Natural Gas Water Heater GU6130T30 User Manual