Page 11
11 Chimney Connection IMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition. • The connector must be installed above the extreme bottom of the chimney...
Page 12
12 Water System Piping Piping Installation Piping, fittings, and valves should be installed according to the installation drawing (Figure 13). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal...
Page 13
13 Please note the following: • The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, or polybutylene. This water heater must not be installed using iron piping or PVC water piping. • Use only pumps, valves, or fittings that are compatible with potable water. • Use only full flow ball or gate valves. The use of valves that may cause excessive restriction to water flow is not recommended. • Use only 95/5 tin-antimony or other...
Page 14
14 Temperature and Pressure Relief Valve Explosion Hazard If the temperature and pressure relief valve is dripping or leaking, have a qualified person replace it. Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel. Do not plug valve. Do not remove valve. Failure to follow these instructions can result in death, or explosion. WARNING For protection against excessive pressures and temperatures, a temperature and pressure...
Page 15
15 • The domestic hot water line from the water heater should be vertical past any mixing valve or supply line to the air handler to remove air bubbles from the sys- tem. Otherwise, these bubbles will be trapped in the air handler heat exchanger coil, reducing the efficiency. • Do not connect the water heater to any system or components previously used with non-potable water heating appliances when used to supply potable water. NOTE: Water heaters covered by this manual are suitable for...
Page 16
16 Water Heater Location Water heater location is important and can affect system performance. Please check the following: □ Installation area free of corrosive elements and flammable materials. □ Centrally located with the water piping system. Located as close to the gas piping and vent pipe system as possible. □ Located indoors and in a vertical position. Protected from freezing temperatures. □ Proper clearances from combustible surfaces maintained and not installed directly on a carpeted...
Page 17
17 OPERATING YOUR WATER HEATER Lighting Instructions Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the viewport is not missing or damaged. (See Figure 23) Make sure the tank is completely filled with water before lighting the pilot. Check the data plate near the gas control valve/ thermostat for the correct gas. Do not use this water heater with any gas other than the one listed on the data plate. If you have any questions or doubts,...
Page 18
18 1. Turn the gas control/temperature knob counterclockwise to the OFF setting. The status light will stop blinking and stay on for a short time after the water heater is turned off. See Figure ‘A’. IMPORTANT/IMPORTANTERead the manual for complete instructions and safety information. For a free manual, call 1-800-821-2017. Lea el manual para instrucciones completas e información de seguridad. Manuales gratuitos, etiquetas, o rótulos en español se pueden obtener llamando al 1-800-821-2017. FOR...
Page 19
19 Burner Flames Inspect the burner flames through the viewport. Flames should be very small with a blue haze and small amounts of yellow or orange at the edges. After several minutes of operation, the burner screen may glow red. If large flames are observed at any time, shut-off unit and call a qualified person. Water Temperature Stacking Stacking occurs when a series of short draws of hot water (3 gallons or less) are taken from the water heater tank. This causes increased cycling of the burner...
Page 20
20 Water Temperature Regulation The thermostat is adjusted to the pilot position when it is shipped from the factory. Water temperature can be regulated by moving the temperature dial to the preferred setting. The preferred starting point is 120°F at the “HOT” setting. Align the knob with the desired water temperature as shown in Figure 19A. There is a hot water scald potential if the thermostat is set too high. NOTE: Temperatures shown on the gas control valve/ thermostat are approximates. The...