557 Long Road Pittsburgh, PA 15235, USA Email: [email protected] www.americansensors.com Tel: 412-242-5903 fax: 412-242-5908 2.2014 OB-3000-F : Optical Barrier 1 OB-3000-F OPTICAL BARRIER RETRO REFLECTIVE SINGLE SENSOR FOR NON-CONTACT, LONG RANGE, PRECISE, DETECTION OF COLD AND HOT PRODUCT FEATURES: LASER DOT POSITIONING IN MILL-DUTY, WATER-COOLED POSITIVE-PRESSURE, AIR-PURGED HOUSING PROXIMITY SENSOR WITHOUT REFLECTOR RELAY OUTPUT: 3A /125 V RESPONSE TIME:
557 Long Road Pittsburgh, PA 15235, USA Email: [email protected] www.americansensors.com Tel: 412-242-5903 fax: 412-242-5908 2014 OB-3000-F : Optical Barrier 2 DESCRIPTION: The OB-3000-F Optical Barrier has a programmable Trip Distance so that the sensor detects an object, hot or cold, that comes across the laser be am. The Trip Distance is set by the user based on the specifications of the user. The sensor will th en look for a change in distance that is shorter th an the Trip Distance and will send out a signal when a change is detected. A green LED is displayed when the product is detected. The OB-3000-F does not need a reflector or emitter on the other side. The sensor trip signal is available as a simple rel ay output and static output. The trip signal will stay active (High/ON) for as l ong as an object is within the measurement beam, and will return to the inactive (Low/OFF) state whe n the object exits the beam. The response time of the output signal is based upo n the fact that the sensor uses 30 laser pulses to determine if the Trip Distance has been exceeded. At a pulse rate of 3 kHz, this computes to a time latency of 10 milliseconds for a state change of th e output signal. DIMENSIONS:
557 Long Road Pittsburgh, PA 15235, USA Email: [email protected] www.americansensors.com Tel: 412-242-5903 fax: 412-242-5908 2014 OB-3000-F : Optical Barrier 3 SPECIFICATIONS: SYSTEM WAVE LENGTH LASER POINTER 650nm WAVE LENGTH MEASUREMENT PULSE 905nm POINTER OPTICAL POW ER 1mW average CLASS Pointer: Class2 Measurement Pulse: Class1 DIVERGENCE 0,6 mrad SIGNALS DETECT RELAY Detect Relay and Solid State Output DIGITAL OUTPUT RATE 5 s/r to 50 r/s RANGE 65 Meters (typical) ELECTRICAL POW ER SUPPLY 100 to 240 VAC / 15 W (50-60 Hz), or 24 VDC / 8 W POW ER CONSUMPTION 20 VA or 10 VA for 24V SHIELDED CABLE 2 Meter, high-temperature Teflon cable CONNECTOR Direct Wire SERIAL LINK DIGITAL COMMUNICATION RS232 or Optional RS485 MECHANICAL HOUSING Cast aluminium housing rating: IP66 (NEMA 4 ) WATER / AIR COOLING Removable water / air-cooling jacket PROTECTIVE HOOD Hood with positive pressure air purge: 4-16 liters/ min at 2 bars (0.14 -0.56 ft3/min at 29 PSI) MOUNTING Fully Adjustable foot mount swivel stand OPERATING TEMPERATURE -28°C to 60°C (-18°F to 140° F) Above 60°C (140° F) auxiliary cooling is required: 1-2 bars at 1-2 liters/min. (14.5 - 29 PSI at 0.035 - 0.07 ft3/min) INSIDE TEMPERATURE ALARM Alarm via Digital Output TOTAL WEIGHT 12.25 kg / 27 lbs. ORDERING INFORMATION: All sensors are equipped with a 2 meter Teflon-shie lded cable with Harting Connector. Please specify if additional length is required. OB-3000-F 100 to 240 VAC _ _ _ _ m (ft)* 24 VDC Input Voltage Optical Barrier Cable Length