Home
>
Aluratek
>
Audio-visual interconnect box
>
Aluratek UNDER TABLE IT INTERCONNECT AUSTRALIA UT240510 User Guide
Aluratek UNDER TABLE IT INTERCONNECT AUSTRALIA UT240510 User Guide
Have a look at the manual Aluratek UNDER TABLE IT INTERCONNECT AUSTRALIA UT240510 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Under the Table Interconnect Solutions Under the Table Interconnect Solutions Under the Table Interconnect Solutions Under the Table Interconnect Solutions User’s Guide 400-0491-005 1 Installation Options Inside Desk (Side View) Table Top (Side View) Back of Desk/Podium (Top View) Desk Surface LEFTSHIELD RIGHT UT240-278 Audio W iring Welcome! We greatly appreciate your purchase of a UT Series. We are sure you will find it reliable and simple to use. Superior performance for the right price, backed by solid technical and customer support is what ALT INEX has to offer. We are committed to providing our customers with Si gnal Management Solutions ® to the most demanding audiovisual installations at competitive pricing and we welcome you to join the ranks of our many satisfied customers throughout the world. 1. Precautions and Safety Warnings Please read this manual carefully before using your UT-Series Interconnect. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your UT-Series Interconnect and to prevent fire and shock hazards. Please read them carefully and heed all warnings. 1.1 General · There are no user serviceable parts inside. Qualifi ed ALTINEX service personnel must perform all service on the UT-Series . 1.2 Handling · To prevent fire or shock, do not expose this unit t o water or moisture. Do not place the UT-Series in direct sunlight, near heaters, or heat-radiating appliances, or near any liquid. Expo sure to direct sunlight, smoke, or steam can harm internal components. · Handle the unit carefully. Dropping or jarring can cause damage. · Do not pull any cables that are attached to the UT- Series. · Do not place heavy objects on top of the UT-Series. 1.3 Cleaning · Unplug the UT-Series before cleaning. · Clean only with a dry cloth. Never use strong deter gents or solvents such as alcohol or thinner. Do not use a wet cloth or wa ter to clean the unit. Do not open the unit to clean. 1.4 FCC Notice · This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device ma y not cause harmful interference, and (2) this device must accept any i nterference received, including interference that may cause undesired ope ration. · This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of th e FCC Rules. These limits are designed to provide reasonable protectio n against harmful interference when the equipment is operated in a co mmercial environment. This equipment generates, uses, and ca n radiate radio frequency energy and if not installed and used in a ccordance with instructions found herein, may cause harmful interf erence to radio communications. Operation of this equipment in a re sidential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own exp ense. · Any changes or modifications to the unit not expres sly approved by ALTINEX, Inc. could void the user’s authority to op erate the equipment. 2. Installation Procedures The UT Series can be installed horizontally or vertically as shown. Typically, units are installed under a tabletop, but in some cases, it may be desirable to install a unit i nside a desk opening, or on the back of a desk or p odium. Step 1. Locate the best position for the UT Interco nnect, but do NOT mount it to the surface until cables are ready. Step 2. Prepare the mating cables using high-qualit y cables for best results and durability. Make sure the cables are long enough to allow for a service-loop and so the cable s can be neatly routed beneath the table to their destinations. Step 3. Prepare network cables using the CAT-6 (RJ- 45) connectors provided with the unit.* The connectors are high-quality snap-in connectors and do not require any tools for installing them into the UT interconnect. Step 4. Secure the unit under the table using the m etal screws provided with the unit. Step 5. Make any necessary connections to the snap- in connectors. Step 6. Use cable-ties to secure the cables to the mounting shelf. Insert the ties through the holes on the bottom of the unit. Step 7. Use the cable clamps provided to secure the cables to the bottom of the table/desk. * Not all units include network connections. Please visit our website: www.altinex.com for information related to the pin out of the cable s. 3. Limited Warranty/Return Policies Please see the ALTINEX website at www.altinex.com for details on warranty and return policies. Note: Connectors are provided but do not include cables. ALTINEX recommends a telecommunications contractor wire the network connectors and verify operation before installing t he UT interconnect.
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description UT240-300 Series Pass-Through Connection T ype (front to back) AC Power NEMA Receptacle to plug 9-10 ft (2.7-3.0 m) cord Stereo Audio 3.5 mm F-F 8 in (200 mm) cable Stereo Audio 3.5 mm F to T erm Block Stereo Audio RCA bulkhead F-F Network (CAT-6) Snap-in RJ-45 connector ( no cable) Modem/phone Snap-in RJ-11 connector ( no cable) Video, Analog 15-pin HD bulkhead, F-F Video, Digital 24-pin DVI bulkhead, F-F Video BNC bulkhead F-F Models (Options) UT240-278 (U.S.) CAT-6 (RJ-45) F (1) Modem (RJ-11) F (1) AC receptacle (1) 15-pin HD F-F (1) 3.5mm F to T erm Block (1) BNC F-F (1) RCA F-F (2) UT240-311 (U.S.) CAT-6 (RJ-45) F (4) AC receptacle (2) UT240-313 (U.S.) 15-pin HD F-F (2) 24-pin DVI F-F (2) 3.5mm F-F (2) CAT-6 (RJ-45) F (4) AC receptacle (2) UT240-310 (U.S.) UT240-411 (EUR) UT240-451 (ENG) UT240-511 (AUS) UT240-551 (UNIV) 15-pin HD F-F (2) CAT-6 (RJ-45) F (4) 3.5mm F-F (2) AC receptacle (2) UT240-312 (U.S.) UT240-410 (EUR) UT240-450 (ENG) UT240-510 (AUS) UT240-550 (UNIV) CAT-6 (RJ-45) F (4) AC receptacle (4) 15A Circuit Breaker (1) Agency Approvals UL/CUL Listed (File E254082) UT240-278, UT240-310, UT240-311, UT240-312, UT240-313 Accessories Included Hardware Mounting hardware Table 1. UT240-300 Series General Mechanical UT240-300 Series Dimensions See the Application Diagrams. Net W eights UT240-278 3.0 lb (1.4 kg) UT240-310 3.0 lb (1.4 kg) UT240-311 2.4 lb (1.1 kg) UT240-312 2.9 lb (1.3 kg) UT240-313 3.0 lb (1.4 kg) UT240-410 3.2 lb (1.5 kg) UT240-411 3.0 lb (1.4 kg) UT240-450 3.0 lb (1.4 kg) UT240-451 3.0 lb (1.4 kg) UT240-510 3.2 lb (1.5 kg) UT240-511 3.0 lb (1.4 kg) UT240-550 3.2 lb (1.5 kg) UT240-551 3.0 lb (1.4 kg) Shipping W eights UT240-278 3.4 lb (1.5 kg) UT240-310 3.4 lb (1.5 kg) UT240-311 2.8 lb (1.3 kg) UT240-312 3.3 lb (1.5 kg) UT240-313 3.4 lb (1.5 kg) UT240-410 3.6 lb (1.6 kg) UT240-411 3.4 lb (1.5 kg) UT240-450 3.4 lb (1.5 kg) UT240-451 3.4 lb (1.5 kg) UT240-510 3.6 lb (1.6 kg) UT240-511 3.4 lb (1.5 kg) UT240-550 3.6 lb (1.6 kg) UT240-551 3.4 lb (1.5 kg) T° Operating 10 °C-35 °C T ° Maximum 50°C Humidity 90% non-condensing Table 2. UT Series Mechanical Electrical UT240-300 Series Pass-Through Signals All standard audio, video, network, and modem signals are acceptable. Pass-Through AC 12 A, 1440 W max. (total through all receptacles) Table 3. UT Series Electrical
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 3 5. About Your UT Interconnect The ALTINEX UT-Series of Under-the-Table AV Interconnects provide a wide variety of options for routing computer audiovisual signals, network connections , and AC power. Under-the-table options are ideal for situations where it is too expensive or impractical to install the routing interface directly into the furniture. The UT240-300 Series are available in both U.S. and international versions. U.S. versions provide standard NEMA 5-15R receptacles; international units in clude AC receptacles for Europe, England, and Australia. The UT240-550 and UT240-551 include universal AC r eceptacles that accept various types of AC plugs. U.S. and international models UT240-312, UT240-410, UT24 0-450, UT240-510, and UT240-550 also include a push-to-reset 15A circuit breaker. Each unit comes standard with 1 or more AC receptac les and 2 or more RJ-45 connectors. The UT240s conn ect to standard AC power outlets through a single 9-10 ft (2.7 to 3.0 m) power cord that is permanent ly attached to the unit. The CAT-6 (RJ-45) connect ors are snap-in style connectors that attach to a support bracket inside the faceplate. The connectors must b e "snapped" out of the bracket, wired to the CAT-5/ 6 cable, and then "snapped" back. The UT240-300 Series units with audio inputs have 3 .5 mm female inputs on the front of the unit and 3.5 mm female inputs on the back via an 8 in (200 mm) cable. The audio receiving devices attach to the ca ble on the back of the unit. The UT240-278 has a 3. 5 mm female input on the front and a terminal block connector with captive screws on the back of the un it. Units with video connectors have female-to-female b ulkhead connectors for both 15-pin HD and 24-pin DV I types. The video receiving devices attach to the bulkhead connectors accessible on the back of the u nit. UT240-310 UT240-311 UT240-312 UT240-313 AC (2) Net (4) Net (4) AC (4) Net (4) AC (2) Net (4) AC (2) DVI-I (2) VGA (2) Audio (2) VGA (2) Audio (2) UT240-411 Europe UT240-511 AustraliaUT240-451 England UT240-551 Universal UT240-510 Australia UT240-410 Europe UT240-450 England UT240-550 Universal * The circuit breaker is located on the inside of t he left-hand side of each unit as viewed from the front. (see Diagra m 14) Circuit Breaker (1) Net (1) AC (1)BNC (1) RCA (2) VGA (1) Audio (1) UT240-278 Phone/modem (1) UT240-313 shown here.
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 4 6. Application Diagrams Diagram 1: Typical Setup UT240-310 Shown Above UT240 Series
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 5 Diagram 2: UT240-310 U.S./Canada Diagram 3: UT240-311 U.S./Canada 3.095 [79mm] 1.850 [47mm] 9.400 [239mm] 10.400 [264mm] 2.300 [58mm] 2.300 [58mm]3.095 [79mm] 1.850 [47mm] 6.636 [169mm] 7.636 [194mm]
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 6 Diagram 4: UT240-312 U.S./Canada Diagram 5: UT240-313 U.S./Canada 1.850 [47mm] 10.400 [264mm] 2.300 [58mm]3.095 [79mm] 9.400 [239mm] 10.596 [269mm] 11.596 [295mm] 2.300 [58mm]3.095 [79mm]
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 7 Diagram 6: UT240-410 Europe Diagram 7: UT240-411 Europe 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 13.294 [338mm] 2.450 [62mm] 12.400 [315mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 11.400 [290mm]
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 8 Diagram 8: UT240-450 England Diagram 9: UT240-451 England 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 13.294 [338mm] 2.450 [62mm] 12.400 [315mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 11.400 [290mm]
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 9 Diagram 10: UT240-510 Australia Diagram 11: UT240-511 Australia 13.294 [338mm] 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 3.095 [79mm] 2.450 [62mm] 11.400 [290mm] 12.400 [315mm] 2.300 [58mm]
UT Series UT Series UT Series UT Series User’s Guide 400-0491-005 10 Diagram 12: UT240-550 Universal Diagram 13: UT240-551 Universal 13.294 [338mm] 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 3.095 [79mm] 2.450 [62mm] 11.400 [290mm] 12.400 [315mm] 2.300 [58mm]