Have a look at the manual Aluratek UNDER TABLE AV INTERCONNECT UNITED KINGDOM UT240451 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
Under the Table Interconnect Solutions Under the Table Interconnect Solutions Under the Table Interconnect Solutions Under the Table Interconnect Solutions User’s Guide 400-0491-004 1 Installation Options Inside Desk (Side View) Table Top (Side View) Back of Desk/Podium (Top View) Desk Surface Welcome! We greatly appreciate your purchase of a UT Series. We are sure you will find it reliable and simple to use. Superior performance f or the right price, backed by solid technical and customer support is what ALTINE X has to offer. We are committed to providing our customers with Signal Management Solutions ® to the most demanding audiovisual installations at very competitive pricing and we welc ome you to join the ranks of our many satisfied customers throughout the world. 1. Precautions and Safety Warnings Please read this manual carefully before using your UT- Series Interconnect. Keep this manual handy for future reference. These s afety instructions are to ensure the long life of your UT-Series Interconnect an d to prevent fire and shock hazards. Please read them carefully and heed al l warnings. 1.1 General · There are no user serviceable parts inside. Qualified A LTINEX service personnel must perform all service on the UT-Series. 1.2 Handling · To prevent fire or shock, do not expose this unit to w ater or moisture. Do not place the UT-Series in direct sunlight, near he aters, or heat-radiating appliances, or near any liquid. Exposu re to direct sunlight, smoke, or steam can harm internal components. · Handle the unit carefully. Dropping or jarring can cause damage. · Do not pull any cables that are attached to the UT-Se ries. · Do not place heavy objects on top of the UT-Series. 1.3 Cleaning · Unplug the UT-Series before cleaning. · Clean only with a dry cloth. Never use strong deterge nts or solvents such as alcohol or thinner. Do not use a wet cloth or wate r to clean the unit. Do not open the unit to clean. 1.4 FCC Notice · This device complies with Part 15 of the FCC Rules. O peration is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any in terference received, including interference that may cause undesired oper ation. · This equipment has been tested and found to comply wit h the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection a gainst harmful interference when the equipment is operated in a co mmercial environment. This equipment generates, uses, and can ra diate radio frequency energy and if not installed and used in acc ordance with instructions found herein, may cause harmful interfe rence to radio communications. Operation of this equipment in a re sidential area is likely to cause harmful interference in which case t he user will be required to correct the interference at his own expe nse. · Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to op erate the equipment. 2. Installation Procedures The UT Series can be installed horizontally or vertica lly as shown. Typically, units are installed under a table-top, but in some cases, it may be desirable to install a unit inside a desk opening, or on the back of a desk or podium. Step 1. Locate the best position for the UT Interconne ct, but do NOT mount it to the surface until all the cables are prepared. Step 2. Prepare the mating cables using high-quality cables for best results and durability. Make sure the cables are long enough to allow for a service-loop and so the cables c an be neatly routed beneath the table to their destinations. Step 3. Prepare the network cables using the CAT-6 (R J-45) connectors provided with the unit.* The connectors are high-quality snap-in connectors and do not require a ny tools for installing them into the UT interconnect. Step 4. Secure the unit under the table using the me tal screws provided with the unit. Step 5. Make any necessary connections to the snap-in c onnectors. Step 6. Use cable-ties to secure the cables to the moun ting shelf. Insert the ties through the holes on the bottom of the unit. Step 7. Use the cable clamps provided to secure the c ables to the bottom of the table/desk. * Please visit our website: www.altinex.com for information related to the pin out of the cabl es. 3. Limited Warranty/Return policies Please see the ALTINEX website at www.altinex.com for details on warranty and return policies. Note: Connectors are provided but do not include cables. ALTINEX recommends a telecommunications contractor wire the network connectors and verify operation before installing t he UT interconnect.
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 2 4. Technical Specifications Specifications are subject to change. See www.altinex.com for up-to-date information. Features/Description UT-Series Pass-Through Connection Type (front to back) AC Power NEMA Receptacle to plug 8 ft (2 m) cord Stereo Audio 3.5 mm F-F 8 in (200 mm) cable Network (CAT-6) Snap-in RJ-45 connector, no cable Video, Analog 15-pin HD bulkhead, F-F Video, Digital 24-pin DVI bulkhead, F-F Models (Options) UT240-311 (U.S.) CAT-6 (RJ-45) female (4) AC receptacle (2) UT240-313 (U.S.) 15-pin HD female (2) 24-pin DVI female (2) 3.5mm stereo (2) CAT-6 (RJ-45) female (4) AC receptacle (2) UT240-310 (U.S.) UT240-411 (EUR) UT240-451 (ENG) UT240-511 (AUS) UT240-551 (UNIV) 15-pin HD female (2) CAT-6 (RJ-45) female (4) 3.5mm stereo (2) AC receptacle (2) UT240-312 (U.S.) UT240-410 (EUR) UT240-450 (ENG) UT240-510 (AUS) UT240-550 (UNIV) CAT-6 (RJ-45) female (4) AC receptacle (4) 15A Circuit Breaker (1) Accessories Included Hardware Mounting screws Table 1. UT240 Series General Mechanical UT-Series Dimensions See the Application Diagrams. Net Weights UT240-310 3.0 lb (1.4 kg) UT240-311 2.4 lb (1.1 kg) UT240-312 2.9 lb (1.3 kg) UT240-313 3.0 lb (1.4 kg) UT240-410 3.2 lb (1.5 kg) UT240-411 3.0 lb (1.4 kg) UT240-450 3.0 lb (1.4 kg) UT240-451 3.0 lb (1.4 kg) UT240-510 3.2 lb (1.5 kg) UT240-511 3.0 lb (1.4 kg) UT240-550 3.2 lb (1.5 kg) UT240-551 3.0 lb (1.4 kg) Shipping Weights UT240-310 3.4 lb (1.5 kg) UT240-311 2.8 lb (1.3 kg) UT240-312 3.3 lb (1.5 kg) UT240-313 3.4 lb (1.5 kg) UT240-410 3.6 lb (1.6 kg) UT240-411 3.4 lb (1.5 kg) UT240-450 3.4 lb (1.5 kg) UT240-451 3.4 lb (1.5 kg) UT240-510 3.6 lb (1.6 kg) UT240-511 3.4 lb (1.5 kg) UT240-550 3.6 lb (1.6 kg) UT240-551 3.4 lb (1.5 kg) T° Operating 10 °C-35 °C T ° Maximum 50°C Humidity 90% non-condensing Table 2. UT240 Series Mechanical Electrical TM-Series Pass-Through Signals All standard audio, video, network, and modem signals are acceptable. Pass-Through AC 600W max. Table 3. UT240 Series Electrical
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 3 UT240-313 shown here. 5. About Your UT Interconnect The ALTINEX UT-Series of Under-the-Table AV Interconnects provide a wide variety of options for routing computer audiovisual signals, network connections, and AC power. Under-the-table options are ideal for situations where it is too expensive or impractical to install the routing interface directly into the furniture. UT-Series are available in both U.S. and internationa l versions. U.S. versions provide standard NEMA 5-15R receptacles; international units include AC receptacles for Europe, England, and Australia. Addi tionally, the UT240-550 and UT240-551 include univers al AC receptacles that accept various types of AC plugs. U.S. and international models UT240-312, UT240-410, UT24 0-450, UT240-510, and UT240-550 also include a push-to-reset 15A circuit breaker. Each unit comes standard with AC receptacles and 4 RJ -45 connectors. The UT240 connects to standard AC powe r outlets through a single 8 ft (2 m) power cord that is permanently attached to the unit. The CAT-6 (RJ-45) connectors are snap-in style connectors that attach to a support bracket on the inside of the faceplate; they are not bulkhead style connectors. Th e connectors must be snapped out of the bracket, wir ed to the CAT-5/6 cable, and then snapped back. Units with audio inputs have 3.5 mm female inputs on th e front of the unit and 3.5 mm female inputs on the back via an 8 in (200 mm) cable. The audio receiving devices attach to the cable on the back of the unit. Units with video connectors have female-to-female bulk head connectors for both 15-pin HD and 24-pin DVI types. The video receiving devices attach to the bulkhead connectors accessible on the back of the unit . UT240-310 UT240-311 UT240-312 UT240-313 AC (2) Net (4) Net (4) AC (4) Net (4) AC (2) Net (4) AC (2) DVI-I (2) VGA (2) Audio (2) VGA (2) UT240-411 Europe UT240-511 Australia UT240-451 England UT240-551 Universal UT240-510 Australia UT240-410 Europe UT240-450 England UT240-550 Universal * The circuit breaker is located on the inside of t he left-hand side of each unit as viewed from the front. (see Diagra m 14) Circuit Breaker (1)
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 4 6. Application Diagrams Diagram 1: Typical Setup UT240-310 Shown Above UT240 Series
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 5 Diagram 2: UT240-310 U.S./Canada Diagram 3: UT240-311 U.S./Canada 3.095 [79mm] 1.850 [47mm] 9.400 [239mm] 10.400 [264mm] 2.300 [58mm] 2.300 [58mm]3.095 [79mm] 1.850 [47mm] 6.636 [169mm] 7.636 [194mm]
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 6 Diagram 4: UT240-312 U.S./Canada Diagram 5: UT240-313 U.S./Canada 1.850 [47mm] 10.400 [264mm] 2.300 [58mm]3.095 [79mm] 9.400 [239mm] 10.596 [269mm] 11.596 [295mm] 2.300 [58mm]3.095 [79mm]
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 7 Diagram 6: UT240-410 Europe Diagram 7: UT240-411 Europe 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 13.294 [338mm] 2.450 [62mm] 12.400 [315mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 11.400 [290mm]
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 8 Diagram 8: UT240-450 England Diagram 9: UT240-451 England 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 13.294 [338mm] 2.450 [62mm] 12.400 [315mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 11.400 [290mm]
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 9 Diagram 10: UT240-510 Australia Diagram 11: UT240-511 Australia 13.294 [338mm] 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 3.095 [79mm] 2.450 [62mm] 11.400 [290mm] 12.400 [315mm] 2.300 [58mm]
![](/img/blank.gif)
UT Series UT Series UT Series UT Series User’s Guide 400-0491-004 10 Diagram 12: UT240-550 Universal Diagram 13: UT240-551 Universal 13.294 [338mm] 14.294 [363mm] 2.300 [58mm]3.095 [79mm] 2.450 [62mm] 3.095 [79mm] 2.450 [62mm] 11.400 [290mm] 12.400 [315mm] 2.300 [58mm]